Trailing & towing
Engineered for heavy-duty mobile mining and industrial trailing duty per MGM 111 / BS 6708 Type 620 / IEC 60228.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per MGM 111 / BS 6708 Type 620 / IEC 60228 across -25 to +90 °C.
Typical values for this cable type, based on MGM 111 / BS 6708 Type 620 / IEC 60228 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per MGM 111 / BS 6708 Type 620 / IEC 60228 across -25 to +90 °C.
Engineered for heavy-duty mobile mining and industrial trailing duty per MGM 111 / BS 6708 Type 620 / IEC 60228.
Suitable for underground coal/hard-rock roadways, shuttle cars and quarry feeders (-25 to +90 °C).
Can be installed on cable trays, hangers and mobile skid interconnections within 10 × OD.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: MGM 111 Type 620 (MGM 111 / BS 6708 Type 620 / IEC 60228) featuring phase conductors (3×50 mm²), epr insulation & composite braid and separator tape & pcp outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Phase Conductors (3×50 mm²) | IEC 60228 Class 5 flexible tinned copper + semicon conductor screen |
| 2 | EPR Insulation & Composite Braid | 5.0 mm EPR + semicon layer + tinned copper/nylon braid screen |
| 3 | Earth Conductor (1×25 mm²) | Uninsulated flexible tinned copper conductor with composite braid screen |
| 4 | Black Bedding & Pliable Steel Armour | Black rubber inner bedding + 7/0.9 mm galvanized steel strand armour |
| 5 | Separator Tape & PCP Outer Sheath | Water-blocking separator tape + black heavy-duty PCP outer jacket |
Built to MGM 111 / BS 6708 Type 620 / IEC 60228 with phase conductors (3×50 mm²) and separator tape & pcp outer sheath
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to MGM 111 / BS 6708 Type 620 / IEC 60228 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| MGM 111 Type 620 Construction Schedule (-25 to +90 °C) | |||||||
| MGM 111 Type 620 3×35 + 1×16 mm² | 3 × 35 mm² + 1 × 16 mm² (E) | Class 5 tinned Cu | 54.0 | 4,620 | 28.0 | 540 | |
| MGM 111 Type 620 3×50 + 1×25 mm² | 3 × 50 mm² + 1 × 25 mm² (E) | Class 5 tinned Cu | 58.6 | 5,580 | 36.0 | 585 | |
| MGM 111 Type 620 3×95 + 1×35 mm² | 3 × 95 mm² + 1 × 35 mm² (E) | Class 5 tinned Cu | 69.4 | 8,190 | 55.0 | 695 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 35 mm² + 1 × 16 mm² (E) | 0.57 | 3.8/6.6 kV (155 A) | -25 to +90 °C |
| 3 × 50 mm² + 1 × 25 mm² (E) | 0.39 | 3.8/6.6 kV (190 A) | -25 to +90 °C |
| 3 × 95 mm² + 1 × 35 mm² (E) | 0.21 | 3.8/6.6 kV (280 A) | -25 to +90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (MGM 111 / BS 6708 Type 620 / IEC 60228) | DC resistance at 20 °C / optical attenuation and outer diameter within MGM 111 / BS 6708 Type 620 / IEC 60228 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (MGM 111 / BS 6708 Type 620 / IEC 60228) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (MGM 111 / BS 6708 Type 620 / IEC 60228) | Verified flame retardancy, mechanical integrity and thermal endurance across -25 to +90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.