Contact
Central tension-core flexible mine control cableTU 16-505.167-78380/660 V AC / 500 V DCCentral Tension Core

KGVSh 380/660 V Underground Mine Control & Interlock CableKGVSh 380/660 V AC (500 V DC) flexible underground coal mine control and face-conveyor interlock cable to TU 16-505.167-78, featuring a central polyester load-bearing core, single-layer Class 4/5 copper conductors and a hermetic FR-PVC jacket.

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per TU 16-505.167-78 / GOST 22483 across -30 to +70 °C.

Anti-torsion braid
Oil-resistant
Flame-retardant
Approved
Order designation
KGVSh 10×1.5 mm²
Outer Ø ≈
15.6 mm
Net weight ≈
340 kg/km
Tensile rating ≈
2.6 kN
Core / stranding
Class 5 bare Cu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
380/660 V
380/660 V AC & 500 V DC mine control
Operating temp.
-30 to +70 °C
Continuous mining & industrial duty
Min. bend radius
8 × OD
Fixed installation / dynamic routing
Core / conductor
5–12×1.0–2.5 mm²
GOST 22483 Class 4/5 bare copper
Outer protection
Hermetic FR-PVC
Pressure-extruded mining PVC sheath
Standard
TU 16-505.167
TU 16-505.167-78 / GOST 22483

Typical values for this cable type, based on TU 16-505.167-78 / GOST 22483 — confirmed in the datasheet and quotation for your order.

Application fit

Is KGVSh right for your machine?

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per TU 16-505.167-78 / GOST 22483 across -30 to +70 °C.

Mine roadway & tunnel wall hangers

Suitable

Engineered for underground mining shafts, galleries and tunnel infrastructure per TU 16-505.167-78 / GOST 22483.

Fixed installation

Suitable

Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 8 × OD.

Free-hanging vertical run

Suitable

Supports inclined roadway and vertical mine shaft suspension within rated kN load across -30 to +70 °C.

Typical machinesMining & TunnellingUnderground Coal & Hard-Rock MiningOpen-Cast Excavators, Draglines & ShovelsVertical Mine Shafts, Hoists & BoreholesTunneling, Mineral Processing & Slurry Plants

Construction

Layer by layer

Shown: KGVSh (TU 16-505.167-78 / GOST 22483) featuring central polyester tension core, flexible conductors (10×1.5 mm²) and hermetic mining pvc jacket (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Central Polyester Tension CoreTwisted high-tenacity polyester yarn core absorbing axial pulling loads
2Flexible Conductors (10×1.5 mm²)GOST 22483 Class 4/5 flexible multi-wire bare copper conductors
3PVC Core InsulationColor-coded PVC compound (≥1×10¹¹ Ω·cm) stranded tightly around central core
4Hermetic Mining PVC JacketExtruded oil-, tear- and flame-resistant PVC jacket locking core interstices

KGVSh — Standard Mining Execution

Built to TU 16-505.167-78 / GOST 22483 with central polyester tension core and hermetic mining pvc jacket

KGVSh — Custom Drum Length & Gland Kit

Available in custom shaft/roadway drum lengths or pre-terminated assemblies

KGVSh — Routine & Flame Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on TU 16-505.167-78 / GOST 22483. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
380/660 V (TU 16-505.167-78 / GOST 22483)
Core / conductor construction
Central Polyester Tension Core — Twisted high-tenacity polyester yarn core absorbing axial pulling loads
Primary dielectric / buffering
Flexible Conductors (10×1.5 mm²) — GOST 22483 Class 4/5 flexible multi-wire bare copper conductors

Thermal

Continuous operating temperature
-30 to +70 °C (mining & industrial service)
Short-circuit / peak thermal rating
Verified thermal stability per TU 16-505.167-78 / GOST 22483
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Hermetic Mining PVC Jacket — Extruded oil-, tear- and flame-resistant PVC jacket locking core interstices
Minimum bending radius
8 × OD
Crush, impact & abrasion duty
Heavy-duty mining rock-cut, impact and tensile protection per TU 16-505.167-78 / GOST 22483

Resistance

Flame retardancy & mine fire safety
Self-extinguishing / flame-retardant mining jacket per TU 16-505.167-78 / GOST 22483
Mine water, oil & chemical resistance
Resistant to acidic mine water, hydraulic oils and abrasion per TU 16-505.167-78 / GOST 22483
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
TU 16-505.167-78 / GOST 22483
Flame & environmental test standards
IEC 60332 / MSHA / EN 60794 / IEC 60228
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
KGVSh
Sheath colour & metre marking
Continuous metre-marked red mining outer sheath
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard KGVSh mining & industrial configurations

Manufactured to TU 16-505.167-78 / GOST 22483 for underground mining, open-cast excavation, shaft and heavy industrial systems.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
KGVSh Construction Schedule (-30 to +70 °C)
KGVSh 6×1.5 mm²6 × 1.5 mm² + Central CoreClass 5 bare Cu12.22151.898
KGVSh 10×1.5 mm²10 × 1.5 mm² + Central CoreClass 5 bare Cu15.63402.6125
KGVSh 12×2.5 mm²12 × 2.5 mm² + Central CoreClass 5 bare Cu19.45453.8155
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per TU 16-505.167-78 / GOST 22483.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (TU 16-505.167-78 / GOST 22483)DC resistance at 20 °C / optical attenuation and outer diameter within TU 16-505.167-78 / GOST 22483 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (TU 16-505.167-78 / GOST 22483)Zero dielectric breakdown and verified insulation resistance over full production lengthEvery manufactured drum length
Sample tests
Flame propagation, mechanical crush & thermal ageing qualification (TU 16-505.167-78 / GOST 22483)Verified flame retardancy, mechanical integrity and thermal endurance across -30 to +70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

TU 16-505.167 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX KGVSh TU 16-505.167 380/660 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel mine reels
Standard lengths
500 m, 1,000 m or custom continuous shaft/reeling lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-24
Updated
2026-10-24

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define KGVSh (KGVSh 380/660 V Underground Mine Control & Interlock Cable)?
KGVSh (KGVSh 380/660 V Underground Mine Control & Interlock Cable) is manufactured in accordance with TU 16-505.167-78 / GOST 22483 for 380/660 V duty over -30 to +70 °C. Its 4-layer construction comprises Central Polyester Tension Core, Flexible Conductors (10×1.5 mm²) and Hermetic Mining PVC Jacket.
What is the minimum bending radius and operating temperature range for KGVSh?
The minimum bending radius for KGVSh is 8 × OD across its continuous operating temperature range of -30 to +70 °C, ensuring mechanical and dielectric reliability in mining and heavy industrial service.
How are the concentric layers of KGVSh arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Central Polyester Tension Core (Twisted high-tenacity polyester yarn core absorbing axial pulling loads); (02) Flexible Conductors (10×1.5 mm²) (GOST 22483 Class 4/5 flexible multi-wire bare copper conductors); (03) PVC Core Insulation (Color-coded PVC compound (≥1×10¹¹ Ω·cm) stranded tightly around central core); (04) Hermetic Mining PVC Jacket (Extruded oil-, tear- and flame-resistant PVC jacket locking core interstices).
What factory test certificates are supplied with KGVSh?
Every production drum of KGVSh undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per TU 16-505.167-78 / GOST 22483, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for KGVSh

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

KGVSh 380/660 V Underground Mine Control & Interlock Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote