Câblage d’armoires et cellules électriques
Transmits low-voltage sensor et gate signals onto a deck floating at 5 kVAC or 15 kVDC relative à earth.
Produit
HSC-5-7X2SVA-2 5 kVAC / 15 kVDC floating-potential control cable isolating a 7 × AWG 26 low-voltage control bundle inside an inner floating screen, stress-controlled XLPE high-voltage barrier, outer grounded EMC cuivre braid et a red PVC jacket.
Valeurs types pour ce type de câble, basés sur DIN 47100 / IEC 60502 (spécification technique) — confirmées dans la fiche technique et le devis de votre commande.
Applications
HSC-5-7X2SVA-2 5 kVAC / 15 kVDC floating-potential control cable isolating a 7 × AWG 26 low-voltage control bundle inside an inner floating screen, stress-controlled XLPE high-voltage barrier, outer grounded EMC cuivre braid et a red PVC jacket.
Transmits low-voltage sensor et gate signals onto a deck floating at 5 kVAC or 15 kVDC relative à earth.
Inner/outer semiconductive PE + XLPE HV barrier prevents partial discharge between Screen I et Screen II.
Dual concentric étamé cuivre braids shield sensitive control signals against dV/dt switching transients.
High-voltage potential-isolation control cable pour fixed cabinets et test cells; not pour crane reels.
L-2YYQY (spécification technique)Construction
Shown: HSC-5-7X2SVA-2 (DIN 47100 / IEC 60502) featuring control bundle (7xawg 26), inner screen i (floating hv) et gaine extérieure (-2 red) (5-layer construction).
| # | Couche | Matériau et référence |
|---|---|---|
| 1 | Control Bundle (7xAWG 26) (spécification technique) | Seven 7 x 0.16 mm (0.14 mm², AWG 26) stranded étamé cuivre control cores avec DIN 47100 polypropylene (PP) isolation (300 V core-to-screen I)DIN 47100 / IEC 60502 (spécification technique) |
| 2 | Inner Screen I (Floating HV) (spécification technique) | Polyester separator tape et inner étamé cuivre wire braid screen I operating at floating high-voltage potentialDIN 47100 / IEC 60502 (spécification technique) |
| 3 | HV Stress-Controlled Barrier (spécification technique) | Co-extruded inner semiconductive PE layer, thick crosslinked polyethylene (XLPE / PE-X) 5 kVAC / 15 kVDC barrier, et outer semicon PEDIN 47100 / IEC 60502 (spécification technique) |
| 4 | Outer Screen II (Earth) (spécification technique) | Outer étamé cuivre wire braid shield II referenced à earth potential pour personnel safety et EMC containmentDIN 47100 / IEC 60502 (spécification technique) |
| 5 | Gaine extérieure (-2 Red) | Red silk-mat polyvinyl chloride (PVC) gaine extérieure (OD 11.4 mm) identifying high-voltage floating-potential circuitsDIN 47100 / IEC 60502 (spécification technique) |
Built à DIN 47100 / IEC 60502 avec control bundle (7xawg 26) et gaine extérieure (-2 red)
Available in custom drum lengths, core counts or factory-terminated assemblies (spécification technique)
Supplied avec EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Données techniques
Dimensions
Manufactured à DIN 47100 / IEC 60502 pour de service intensif industrial et specialty engineering systems.
| Désignation de commande | Configuration | Âme / câblage | Ø extérieur ≈ mm | Masse ≈ kg/km | Tensile load kN ≈ (spécification technique) | Rayon min. R mm | Demande |
|---|---|---|---|---|---|---|---|
| HSC-5-7X2SVA-2 Construction Schedule (−30…+80 °C) (spécification technique) | |||||||
| HSC-5-4X2SVA-2 (4×AWG 26, 15 kVDC) | 4 × AWG 26 (0.14 mm²) (spécification technique) | 7×0.16 mm étamé Cu + 2×screen | 10.2 | 148 | 0.4 | 102 | |
| HSC-5-7X2SVA-2 (7×AWG 26, 15 kVDC) | 7 × AWG 26 (0.14 mm²) (spécification technique) | 7×0.16 mm étamé Cu + 2×screen | 11.4 | 185 | 0.6 | 114 | |
| HSC-5-12X2SVA-2 (12×AWG 26, 15 kVDC) | 12 × AWG 26 (0.14 mm²) (spécification technique) | 7×0.16 mm étamé Cu + 2×screen | 13.2 | 245 | 0.9 | 132 | |
| Configuration | R₂₀ DC max. / Attén. Ω/km ou dB/km | Rating / Capacity (spécification technique) | Temp. de service |
|---|---|---|---|
| 4 × AWG 26 (300 V / 15 kVDC) (spécification technique) | 138.00 | 5 kVAC / 15 kVDC isolation (spécification technique) | −30…+80 °C |
| 7 × AWG 26 (300 V / 15 kVDC) (spécification technique) | 138.00 | 5 kVAC / 15 kVDC isolation (spécification technique) | −30…+80 °C |
| 12 × AWG 26 (300 V / 15 kVDC) (spécification technique) | 138.00 | 5 kVAC / 15 kVDC isolation (spécification technique) | −30…+80 °C |
Qualité et homologations
Essais individuels sur chaque longueur produite, essais sur prélèvements et de type par lot — documentés sur un certificat EN 10204 3.1.
| Essais et contrôle | Valeur d’essai / référence | Fréquence |
|---|---|---|
| Essais individuels | ||
| Conductor resistance & dimensional verification (DIN 47100 / IEC 60502) (spécification technique) | Electrical parameters et outer diameter within DIN 47100 / IEC 60502 tolerances | Every manufactured drum / length (spécification technique) |
| High-voltage dielectric & isolation resistance test (DIN 47100 / IEC 60502) | Zero dielectric breakdown et verified isolation resistance over full length | Every manufactured drum / length (spécification technique) |
| Essais sur prélèvements | ||
| Thermal ageing, mechanical flexing & environmental qualification (DIN 47100 / IEC 60502) (spécification technique) | Verified structural et dielectric integrity across −30…+80 °C | Qualification de type et audit périodique de lot |
Marquage et livraison
Marquage de la gaine
Documents techniques
FAQ
Une autre question ? Envoyez votre plan — un ingénieur répond sous 2 heures ouvrées.
Demander un devis
Votre sélection et les détails de l’application sont copiés dans le formulaire ci-dessous.
Utilisez + Ajouter à côté d’une dimension ou configuration.
Ajoutez ici vos conditions de service pour les inclure dans votre demande.