Contact
shore-to-ship & derrick reeling cableIEC/IEEE 80005-16/10 kV – 8.7/15 kV (-40 to +90 °C)Double 5GM5 Polychloroprene Sheath

HVSC 6/10 & 8.7/15 kV IEC/IEEE 80005-1 High-Voltage Shore Connection Electro-Optical Reeling CableIEC/IEEE 80005-1 — 6/10 kV – 8.7/15 kV — -40 to +90 °C Marine & Offshore Cable

HVSC 6/10 kV & 8.7/15 kV (IEC/IEEE 80005-1) Three-Core MV Power with Split Earth, 24-Fiber Optic & Pilot Cores Anti-Torsion Polychloroprene Shore-to-Ship Reeling Cable (IEC/IEEE 80005-1, 6/10 kV – 8.7/15 kV, -40 to +90 °C).

Flame-retardant
EMC screen
Oil-resistant
Approved
Order designation
HVSC 6/10 & 8.7/15 KV 3×70+2G25+24F
Outer Ø ≈
58.0 mm
Net weight ≈
5,420 kg/km
Tensile rating ≈
31.5 kN
Core / stranding
IEC 60228 Class 5 flexible Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
6/10 kV – 8.7/15
Tested per IEC/IEEE 80005-1
Operating temp.
−40…+90 °C
Continuous shipboard & offshore service
Min. bend radius
10 × OD
Marine tray, bulkhead & deck routing
Core / conductor
HVSC MV Phase Co
Class 5 tinned copper with triple-extrud
Outer protection
Double 5GM5 Poly
Heavy-duty oil-, seawater- and abrasion-
Standard
IEC/IEEE 80005-1
IEC/IEEE 80005-1 High-Voltage Shore Conn

Typical values for this cable type, based on IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813 — confirmed in the datasheet and quotation for your order.

Application fit

Is HVSC 6/10 & 8.7/15 KV (IEC 80005-1) right for your machine?

HVSC 6/10 kV & 8.7/15 kV (IEC/IEEE 80005-1) Three-Core MV Power with Split Earth, 24-Fiber Optic & Pilot Cores Anti-Torsion Polychloroprene Shore-to-Ship Reeling Cable (IEC/IEEE 80005-1, 6/10 kV – 8.7/15 kV, -40 to +90 °C).

Quayside shore-to-ship HVSC connection

Suitable

IEC/IEEE 80005-1 compliant HVSC electro-optical design supplies clean berth power with integrated pilot and fibre cores.

Motorised monospiral reel

Suitable

Integrated anti-torsion braid and flexible Class 5 conductors withstand continuous motorized reeling and tensioning.

Drilling jumbo & rotary mast feed

Suitable

Top-drive service loop execution handles continuous vertical flexing, torsion and ester drilling mud splash in the derrick.

Immersion & wet locations

Suitable

Heavy-duty polychloroprene / CSP / Type P outer sheath resists seawater immersion, quayside abrasion, oil and UV.

Energy chain / drag chain

Not suitable

Heavy shore-power and derrick reeling cable is not intended for small-radius indoor factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CablePort Cold-Ironing / Shore Power (AMP / HVSC)Container, Cruise & Ro-Ro Berth ReelsOffshore Drilling Rig Top Drive Service LoopsShipyard & Drydock Mobile Power Feeders

Construction

Layer by layer

Shown: HVSC 6/10 & 8.7/15 KV (IEC 80005-1) (IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813) featuring hvsc mv phase cores (3×95 mm²), interstitial split earth conductors and double 5gm5 polychloroprene sheath (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1HVSC MV Phase Cores (3×95 mm²)Class 5 tinned copper with triple-extruded EPR insulation (6/10–8.7/15 kV)
2Interstitial Split Earth ConductorsFlexible tinned copper earth cores in outer interstices
3IEC 80005-1 Fiber-Optic & Pilot UnitIntegrated optical fiber & pilot control sub-unit for shore-ship interlock
4Anti-Torsion Reinforcement BraidEmbedded synthetic anti-torsion braid between inner and outer sheaths
5Double 5GM5 Polychloroprene SheathHeavy-duty oil-, seawater- and abrasion-resistant reeling jacket

HVSC 6/10 & 8.7/15 KV (IEC 80005-1) — Standard Shipboard & Offshore Execution

Built to IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813 with hvsc mv phase cores (3×95 mm²) and double 5gm5 polychloroprene sheath

HVSC 6/10 & 8.7/15 KV (IEC 80005-1) — Custom Drum Length & Gland Kit

Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands

HVSC 6/10 & 8.7/15 KV (IEC 80005-1) — Class & Routine Test Certified

Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
6/10 kV – 8.7/15 kV (IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813)
Core / conductor construction
HVSC MV Phase Cores (3×95 mm²) — Class 5 tinned copper with triple-extruded EPR insulation (6/10–8.7/15 kV)
Primary dielectric / buffering
Interstitial Split Earth Conductors — Flexible tinned copper earth cores in outer interstices

Thermal

Continuous operating temperature
−40…+90 °C (shipboard & offshore duty)
Short-circuit / peak thermal rating
Verified thermal stability per IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Double 5GM5 Polychloroprene Sheath — Heavy-duty oil-, seawater- and abrasion-resistant reeling jacket
Minimum bending radius
10 × OD
Armour, screen & mechanical duty
Anti-Torsion Reinforcement Braid — Embedded synthetic anti-torsion braid between inner and outer sheaths

Resistance

Flame, fire & smoke performance
Qualified for marine flame-retardance and low-smoke zero-halogen / fire safety per IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813
Oil, drilling mud & seawater resistance
Resistant to marine fuel/lube oils, salt mist and offshore fluids per IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813
Environmental & test standards
IEC 60228 / IEC 60332-3-22 / IEC 60754 / IEC 61034 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
HVSC 6/10 & 8.7/15 KV (IEC 80005-1)
Sheath colour & metre marking
Continuous metre-marked black outer finish (Double 5GM5 Poly)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard HVSC 6/10 & 8.7/15 KV (IEC 80005-1) shipboard & offshore configurations

Manufactured to IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813 for shipboard, offshore platform, drilling rig and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
HVSC 6/10 & 8.7/15 KV (IEC 80005-1) Construction Schedule (−40…+90 °C)
HVSC 6/10 & 8.7/15 KV 3×70+2G25+24F3×70 + 2×25 mm² + 2×Pilot + 24FIEC 60228 Class 5 flexible Cu/SnCu58.05,42031.5580
HVSC 6/10 & 8.7/15 KV 3×95+2G35+24F3×95 + 2×35 mm² + 2×Pilot + 24FIEC 60228 Class 5 flexible Cu/SnCu63.56,78042.8635
HVSC 6/10 & 8.7/15 KV 3×150+2G50+24F3×150 + 2×50 mm² + 2×Pilot + 24FIEC 60228 Class 5 flexible Cu/SnCu72.49,35067.5725
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813)DC resistance at 20 °C / optical attenuation and outer diameter within IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813)Zero dielectric breakdown and verified insulation resistance for 6/10 kV – 8.7/15 kV ratingEvery manufactured drum length
Sample tests
Flame, fire integrity, oil/mud & mechanical qualification (IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813)Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC/IEEE 80005-1 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX HVSC 6/10 & 8.7/15 KV (IEC 80005-1) IEC/IEEE 80005-1 6/10 kV – 8.7/15 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel marine reels
Standard lengths
500 m, 1,000 m or custom continuous shipboard/offshore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define HVSC 6/10 & 8.7/15 KV (IEC 80005-1) (HVSC 6/10 & 8.7/15 kV IEC/IEEE 80005-1 High-Voltage Shore Connection Electro-Optical Reeling Cable)?
HVSC 6/10 & 8.7/15 KV (IEC 80005-1) (HVSC 6/10 & 8.7/15 kV IEC/IEEE 80005-1 High-Voltage Shore Connection Electro-Optical Reeling Cable) is manufactured in accordance with IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813 for 6/10 kV – 8.7/15 kV service over -40 to +90 °C. Its 5-layer construction comprises hvsc mv phase cores (3×95 mm²), interstitial split earth conductors and double 5gm5 polychloroprene sheath.
What is the minimum bending radius and operating temperature range for HVSC 6/10 & 8.7/15 KV (IEC 80005-1)?
The minimum bending radius for HVSC 6/10 & 8.7/15 KV (IEC 80005-1) is 10 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical and dielectric reliability in shipboard and offshore service.
How are the concentric layers of HVSC 6/10 & 8.7/15 KV (IEC 80005-1) arranged from inside to outside?
From inside to outside, the construction sequence is: (01) HVSC MV Phase Cores (3×95 mm²) — Class 5 tinned copper with triple-extruded EPR insulation (6/10–8.7/15 kV); (02) Interstitial Split Earth Conductors — Flexible tinned copper earth cores in outer interstices; (03) IEC 80005-1 Fiber-Optic & Pilot Unit — Integrated optical fiber & pilot control sub-unit for shore-ship interlock; (04) Anti-Torsion Reinforcement Braid — Embedded synthetic anti-torsion braid between inner and outer sheaths; (05) Double 5GM5 Polychloroprene Sheath — Heavy-duty oil-, seawater- and abrasion-resistant reeling jacket.
What factory test certificates are supplied with HVSC 6/10 & 8.7/15 KV (IEC 80005-1)?
Every production drum of HVSC 6/10 & 8.7/15 KV (IEC 80005-1) undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per IEC/IEEE 80005-1 High-Voltage Shore Connection (HVSC) / DIN VDE 0250-813, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for HVSC 6/10 & 8.7/15 KV (IEC 80005-1)

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

HVSC 6/10 & 8.7/15 kV IEC/IEEE 80005-1 High-Voltage Shore Connection Electro-Optical Reeling Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote