Trailing & towing
Portable tools, cold-room appliances, winter outdoor instruments and heating devices in oil-free areas.
Product
Harmonised 300/500 V flexible rubber cable to EN 50525-2-21 featuring Class 5 copper conductors, +90 °C EI6 ethylene-propylene rubber insulation and an EM6 EPR elastomer outer sheath engineered for sub-zero flexing down to −40 °C and +90 °C thermal duty.
Typical values for this cable type, based on EN 50525-2-21 (HD 22.12) — confirmed in the datasheet and quotation for your order.
Application fit
H05BB-F uses EI6/EM6 ethylene-propylene rubber for both core insulation and outer sheath, giving exceptional −40 °C cold elasticity and +90 °C heat resistance in oil-free environments.
Portable tools, cold-room appliances, winter outdoor instruments and heating devices in oil-free areas.
Refrigerated warehouses, blast freezers, outdoor alpine cabinets and hot luminaire connections.
Weather-, UV- and moisture-resistant outdoors, but not intended for oily sumps or permanent immersion.
Use H05RN-F / H05BQ-FLight 300/500 V cord not intended for high-tension motorised drum reeling.
Use S07BQ-F ReinforcedConstruction
Shown: H05BB-F 3G1.0 — Class 5 bare copper conductors, EI6 EPR core insulation (HD 308 S2 colour code) and black EM6 EPR elastomer outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible copper conductor | Fine-stranded bare copper wire (IEC 60228 Class 5)EN 60228 Class 5 |
| 2 | Cold/heat EPR insulation | Cross-linked ethylene-propylene elastomer compound Type EI6 (−40 to +90 °C)EN 50363-1 EI6 |
| 3 | EPR elastomer outer sheath | Cross-linked ethylene-propylene rubber compound Type EM6, blackEN 50363-2-1 EM6 · halogen-free, ozone & cold resistant |
Harmonised EN 50525-2-21 Table B.2 sizes with EI6/EM6 EPR compounds
Extended 300/500 V sizes for cold-climate and +90 °C appliance connections
Technical data
Sizes
Typical EN 50525-2-21 (HD 22.12) outer diameter limits, copper content and cable weight.
| Order designation | Cores × mm² | AWG ≈ | Outer Ø min mm | Outer Ø max mm | Copper kg/km | Weight ≈ kg/km | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|---|
| Harmonised H05BB-F sizes (0.75–1.0 mm² per EN 50525-2-21 Table B.2) | ||||||||
| H05BB-F 2×0.75 | 2×0.75 | 18 | 5.7 | 6.2 | 14 | 50 | 25 | |
| H05BB-F 3G0.75 | 3G0.75 | 18 | 6.2 | 6.7 | 22 | 62 | 27 | |
| H05BB-F 4G0.75 | 4G0.75 | 18 | 6.7 | 7.3 | 29 | 75 | 29 | |
| H05BB-F 5G0.75 | 5G0.75 | 18 | 7.5 | 8.1 | 36 | 91 | 32 | |
| H05BB-F 2×1.0 | 2×1.0 | 17 | 6.1 | 6.6 | 19 | 59 | 26 | |
| H05BB-F 3G1.0 | 3G1.0 | 17 | 6.5 | 7.1 | 29 | 73 | 28 | |
| H05BB-F 4G1.0 | 4G1.0 | 17 | 7.2 | 7.8 | 38 | 90 | 31 | |
| H05BB-F 5G1.0 | 5G1.0 | 17 | 7.9 | 8.6 | 48 | 109 | 34 | |
| Extended 05BB-F sizes (1.5–2.5 mm²) | ||||||||
| 05BB-F 3G1.5 | 3G1.5 | 16 | 8.2 | 8.9 | 43 | 114 | 36 | |
| 05BB-F 4G1.5 | 4G1.5 | 16 | 9.1 | 9.9 | 58 | 142 | 40 | |
| 05BB-F 5G1.5 | 5G1.5 | 16 | 10.0 | 10.9 | 72 | 174 | 44 | |
| 05BB-F 3G2.5 | 3G2.5 | 14 | 9.8 | 10.6 | 72 | 166 | 42 | |
| Cross-section mm² | AWG ≈ | Max. DC resistance 20 °C, Ω/km | 1-core in air 30 °C, A | 3–4 core in air 30 °C, A |
|---|---|---|---|---|
| 0.75 | 18 | 26 | 12 | 10 |
| 1 | 17 | 19.5 | 15 | 13 |
| 1.5 | 16 | 13.3 | 23 | 18 |
| 2.5 | 14 | 7.98 | 30 | 25 |
Reel check
A first screen using datasheet values. Engineering confirms drum geometry, acceleration and tension with your quotation.
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC voltage test | 2.0 kV AC (50 Hz) | Every manufactured length |
| Conductor DC resistance | IEC 60228 Class 5 (bare copper) | Every manufactured length |
| Sample tests | ||
| Vertical flame propagation | IEC 60332-1-2 / EN 60332-1-2 | Per production batch |
| Insulation & sheath elastomer physical properties | EN 50525-2-21 (HD 22.12) | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.