General rubber flexible cablesEN 50525-2-21U0/U 300/500 VEI6/EM6 EPR · −40…+90 °C

H05BB-F Flexible Rubber CableHarmonised 300/500 V −40 to +90 °C EI6/EM6 all-EPR flexible rubber cord

Harmonised 300/500 V flexible rubber cable to EN 50525-2-21 featuring Class 5 copper conductors, +90 °C EI6 ethylene-propylene rubber insulation and an EM6 EPR elastomer outer sheath engineered for sub-zero flexing down to −40 °C and +90 °C thermal duty.

Ozone, UV & moisture
Outdoor & humid
Approved
Halogen-Free EPR
Order designation
H05BB-F 3G1.0
Outer Ø min
6.5 mm
Outer Ø max
7.1 mm
Weight ≈
73 kg/km
Min. bend R
28 mm
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
U0/U · 2.0 kV AC test voltage
Conductor temp.
+90 °C max.
+250 °C short-circuit (5 s)
Ambient temp.
−40…+90 °C
Flexing (−50…+90 °C fixed)
Bending radius
4–6 × OD
4 × OD fixed · 6 × OD flexing
Compounds
EI6 / EM6
All-EPR core & sheath (halogen-free)
Size range
0.75–2.5 mm²
2 to 5 cores · Class 5 Cu

Typical values for this cable type, based on EN 50525-2-21 (HD 22.12) — confirmed in the datasheet and quotation for your order.

Application fit

Is H05BB-F right for your machine?

H05BB-F uses EI6/EM6 ethylene-propylene rubber for both core insulation and outer sheath, giving exceptional −40 °C cold elasticity and +90 °C heat resistance in oil-free environments.

Trailing & towing

Suitable

Portable tools, cold-room appliances, winter outdoor instruments and heating devices in oil-free areas.

Fixed installation

Suitable

Refrigerated warehouses, blast freezers, outdoor alpine cabinets and hot luminaire connections.

Immersion & wet locations

With conditions

Weather-, UV- and moisture-resistant outdoors, but not intended for oily sumps or permanent immersion.

Use H05RN-F / H05BQ-F

Motorised monospiral reel

Not suitable

Light 300/500 V cord not intended for high-tension motorised drum reeling.

Use S07BQ-F Reinforced
Typical machinesCold storage & blast-freezer equipmentNordic & alpine outdoor appliancesCommercial heating & drying unitsHorticultural & greenhouse lightingHalogen-free indoor/outdoor tools

Construction

Layer by layer

Shown: H05BB-F 3G1.0 — Class 5 bare copper conductors, EI6 EPR core insulation (HD 308 S2 colour code) and black EM6 EPR elastomer outer sheath.

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Flexible copper conductorFine-stranded bare copper wire (IEC 60228 Class 5)EN 60228 Class 5
2Cold/heat EPR insulationCross-linked ethylene-propylene elastomer compound Type EI6 (−40 to +90 °C)EN 50363-1 EI6
3EPR elastomer outer sheathCross-linked ethylene-propylene rubber compound Type EM6, blackEN 50363-2-1 EM6 · halogen-free, ozone & cold resistant

H05BB-F (0.75–1.0 mm²)

Harmonised EN 50525-2-21 Table B.2 sizes with EI6/EM6 EPR compounds

05BB-F (1.5–2.5 mm²)

Extended 300/500 V sizes for cold-climate and +90 °C appliance connections

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on EN 50525-2-21 (HD 22.12). Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
300/500 V AC
Max. operating voltage
330/550 V AC
AC test voltage
2000 V AC (50 Hz, 15 min)
Conductor stranding
IEC 60228 Class 5 fine-stranded bare copper
Current rating basis
DIN VDE 0298-4 (+90 °C conductor rating)

Thermal

Max. conductor temperature
+90 °C continuous operation
Short-circuit temperature
+250 °C max. (up to 5 s)
Temperature, flexing
−40 °C to +90 °C
Temperature, fixed
−50 °C to +90 °C

Mechanical

Min. bending radius, fixed
4 × overall diameter (OD ≤ 12 mm: 3 × OD)
Min. bending radius, moving
6 × overall diameter (free movement)
Max. tensile load
15 N/mm² dynamic (50 N/mm² static)
Sub-zero flexibility
EI6/EM6 EPR remains supple at −40 °C without cracking

Resistance

Ozone, UV & weather
EN 60811-403 ozone-immune EPR outer sheath
Halogen-free
IEC 60754-1 halogen-free EI6/EM6 EPR elastomer system
Oil contact note
EM6 EPR sheath is for oil-free zones (use H05BN4-F or H05BQ-F for oil)
Water & moisture
Resistant to condensation, frost, snow and damp outdoor air

Reference standards

Construction standard
EN 50525-2-21 (HD 22.12 S2 / DIN VDE 0285-525-2-21)
Compound standards
EN 50363-1 Type EI6 & EN 50363-2-1 Type EM6
Selection & installation
EN 50565-1 & EN 50565-2
RoHS & REACH
2011/65/EU (RoHS 2) & EC 1907/2006 compliant

Identification

Sheath colour
Black
Core identification
HD 308 S2 colour code (2 to 5 cores)
Sheath marking
TEBAOFLEX H05BB-F <HAR> [Size] 300/500V EN 50525-2-21 CE
Customs tariff (HS)
8544.49 (insulated conductors ≤ 1000 V)

Sizes

12 standard H05BB-F configurations

Typical EN 50525-2-21 (HD 22.12) outer diameter limits, copper content and cable weight.

Dimensions & weights
Order designationCores × mm²AWG ≈Outer Ø min
mm
Outer Ø max
mm
Copper
kg/km
Weight ≈
kg/km
Min. bend R
mm
Enquiry
Harmonised H05BB-F sizes (0.75–1.0 mm² per EN 50525-2-21 Table B.2)
H05BB-F 2×0.752×0.75185.76.2145025
H05BB-F 3G0.753G0.75186.26.7226227
H05BB-F 4G0.754G0.75186.77.3297529
H05BB-F 5G0.755G0.75187.58.1369132
H05BB-F 2×1.02×1.0176.16.6195926
H05BB-F 3G1.03G1.0176.57.1297328
H05BB-F 4G1.04G1.0177.27.8389031
H05BB-F 5G1.05G1.0177.98.64810934
Extended 05BB-F sizes (1.5–2.5 mm²)
05BB-F 3G1.53G1.5168.28.94311436
05BB-F 4G1.54G1.5169.19.95814240
05BB-F 5G1.55G1.51610.010.97217444
05BB-F 3G2.53G2.5149.810.67216642
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are typical values per EN 50525-2-21 (HD 22.12). Minimum fixed bending radius shown is 4 × OD.

Reel check

Will it fit your machine?

A first screen using datasheet values. Engineering confirms drum geometry, acceleration and tension with your quotation.

Check results

Drum core 300 mm ≥ 56 mmBending radius OK (4 × OD 7.1 mm)
Minimum bending radius
28 mm
Min. drum core diameter
≈ 56 mm
Cable weight on drum
3.7 kg
Copper content
1.5 kg
Indicative only: based on the datasheet outer diameter and 4 × OD bending radius. Current derating for wound layers per DIN VDE 0298-4 is assessed separately.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC voltage test2.0 kV AC (50 Hz)Every manufactured length
Conductor DC resistanceIEC 60228 Class 5 (bare copper)Every manufactured length
Sample tests
Vertical flame propagationIEC 60332-1-2 / EN 60332-1-2Per production batch
Insulation & sheath elastomer physical propertiesEN 50525-2-21 (HD 22.12)Type approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

EN 50525-2-21 (HD 22.12)CE · RoHS 2 (2011/65/EU) · REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX H05BB-F 300/500 V [Size] EN 50525-2-21 CE
Delivery form
Export wooden drums or coils, cut-to-length on request
Packaging
Heat-treated ISPM-15 timber drums with sealed cable ends
Conductor / sheath options
Custom core counts, pilot cores or sheath colours on request

Technical documents

Downloads

Revision
2026-10-20
Updated
2026-10-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What does 'BB' stand for in H05BB-F?
In the CENELEC code, both the first 'B' (core insulation) and the second 'B' (outer sheath) denote cross-linked ethylene-propylene rubber (EPR, specifically compounds EI6 and EM6 per EN 50363). This all-EPR construction combines a +90 °C continuous conductor rating with dynamic cold flexibility down to −40 °C.
How does H05BB-F differ from H05BN4-F?
Both H05BB-F and H05BN4-F are rated 300/500 V and +90 °C under EN 50525-2-21 (HD 22.12). H05BB-F uses an EM6 EPR outer sheath that stays flexible down to −40 °C in motion and is naturally halogen-free, whereas H05BN4-F uses an EM7 chlorinated CSP sheath rated to −25 °C flexing that adds mineral oil and flame resistance.
Can H05BB-F be used in blast freezers and cold-storage rooms?
Yes. Because standard polychloroprene (EM2) and CSP (EM7) jackets stiffen below −25 °C, the EI6/EM6 ethylene-propylene elastomer system of H05BB-F (and H07BB-F for larger sizes) is specifically chosen for −40 °C dynamic flexing and −50 °C fixed wiring in cold stores and Nordic outdoor sites.
When should I choose H07BB-F instead of H05BB-F?
Select H05BB-F for light 300/500 V appliances and sensors using 0.75 mm² or 1.0 mm² conductors. For power circuits from 1.5 mm² up to 95 mm² or where a 450/750 V (0.6/1 kV fixed protected) heavy-duty sheath thickness is required, select H07BB-F.

Request a quote

Get an engineering quote for H05BB-F

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

H05BB-F Flexible Rubber Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote