Fixed installation
Routes through split-loom convoluted tubing, body channels and cabin floor harnesses.
Product
Type GPT (General Purpose Thermoplastic) is a standard-wall 60 V DC (25 V AC) low-voltage primary wire manufactured to SAE J1128 for North American automotive, agricultural, marine-cabin and trailer harnesses. Built with concentric stranded ASTM B3 bare copper
Typical values for this cable type, based on SAE J1128 / ISO 6722-1 Class A — confirmed in the datasheet and quotation for your order.
Application fit
Used in general cabin wiring, dashboard harnesses, body lighting looms, agricultural tractors, RV campers and aftermarket trailer harnesses where temperatures do not exceed +85 °C.
Routes through split-loom convoluted tubing, body channels and cabin floor harnesses.
Compatible with standard open-barrel and insulated crimp terminals on fuse blocks and relays.
Single-core primary wire must be enclosed inside a harness loom or jacketed cable.
Multicore Trailer CableThermoplastic PVC softens above +85/+105 °C; use cross-linked TXL/GXL/SXL in hot engine bays.
GXL +125 °C XLPE wireConstruction
ASTM B3 stranded annealed bare copper conductor + regular-wall plasticized thermoplastic PVC dielectric (0.58–1.09 mm) + smooth colour-coded/striped surface skin.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded bare copper conductor | Concentric stranded annealed uncoated copper per ASTM B3 / SAE J1128 (7, 19 or 133 strands)ASTM B3 |
| 2 | Regular-wall thermoplastic PVC | General-purpose plasticized polyvinyl chloride (PVC) insulation rated -40 °C to +85 °C (0.58 mm wall on 20–14 AWG)SAE J1128 |
| 3 | Integral colour-coded outer skin | Smooth low-friction extruded PVC surface layer with optional spiral/longitudinal polarity stripeSAE J1128 |
Standard SAE J1128 Class A (-40 °C to +85 °C) thermoplastic PVC primary wire for body and interior harnesses.
Upgraded +105 °C heat-stabilised PVC formulation for warm instrument panels and fuse-box distribution.
Technical data
Sizes
Nominal dimensions, wall thickness, copper mass and electrical parameters for GPT per SAE J1128 / ISO 6722-1 Class A.
| Designation | AWG (Metric mm²) | Strands / Wall mm | Max. OD mm | Copper kg/km | Total mass ≈ kg/km | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| GPT size range | |||||||
| GPT 20 AWG (0.5 mm²) | 20 AWG (0.5 mm²) | 7/28 · 0.58 mm | 2.50 | 4.9 | 9.2 | 12.5 | |
| GPT 18 AWG (0.8 mm²) | 18 AWG (0.8 mm²) | 16/30 · 0.58 mm | 2.75 | 7.6 | 12.5 | 13.8 | |
| GPT 16 AWG (1.0 mm²) | 16 AWG (1.0 mm²) | 19/29 · 0.58 mm | 3.05 | 11.2 | 16.8 | 15.2 | |
| GPT 14 AWG (2.0 mm²) | 14 AWG (2.0 mm²) | 19/27 · 0.58 mm | 3.45 | 17.8 | 24.5 | 17.2 | |
| GPT 12 AWG (3.0 mm²) | 12 AWG (3.0 mm²) | 19/25 · 0.66 mm | 4.20 | 28.2 | 37.5 | 21.0 | |
| GPT 10 AWG (5.0 mm²) | 10 AWG (5.0 mm²) | 19/23 · 0.79 mm | 5.10 | 45.0 | 58.5 | 25.5 | |
| GPT 8 AWG (8.0 mm²) | 8 AWG (8.0 mm²) | 19/21 · 0.94 mm | 6.20 | 71.5 | 91.0 | 31.0 | |
| GPT 18 AWG 19-Strand | 18 AWG (19/30) | 19/30 · 0.58 mm | 2.80 | 8.9 | 13.8 | 14.0 | |
| GPT 16 AWG 26-Strand | 16 AWG (26/30) | 26/30 · 0.58 mm | 3.10 | 12.1 | 17.8 | 15.5 | |
| GPT 14 AWG 41-Strand | 14 AWG (41/30) | 41/30 · 0.58 mm | 3.50 | 19.1 | 26.0 | 17.5 | |
| GPT 12 AWG 65-Strand | 12 AWG (65/30) | 65/30 · 0.66 mm | 4.25 | 30.2 | 39.8 | 21.2 | |
| GPT 10 AWG 105-Strand | 10 AWG (105/30) | 105/30 · 0.79 mm | 5.15 | 48.5 | 62.0 | 25.8 | |
| AWG (Metric mm²) | Max. DC R @ 20 °C mΩ/m | Single wire in air A | In harness bundle A |
|---|---|---|---|
| 20 AWG (0.5 mm²) | 34.60 | 11 | 9 |
| 18 AWG (0.8 mm²) | 21.40 | 15 | 12 |
| 16 AWG (1.0 mm²) | 14.60 | 19 | 15 |
| 14 AWG (2.0 mm²) | 9.18 | 26 | 20 |
| 12 AWG (3.0 mm²) | 5.77 | 35 | 27 |
| 10 AWG (5.0 mm²) | 3.63 | 48 | 37 |
| 8 AWG (8.0 mm²) | 2.28 | 65 | 51 |
| 18 AWG (19/30) | 19.20 | 16 | 12 |
| 16 AWG (26/30) | 13.80 | 20 | 16 |
| 14 AWG (41/30) | 8.90 | 27 | 21 |
| 12 AWG (65/30) | 5.58 | 36 | 28 |
| 10 AWG (105/30) | 3.52 | 50 | 39 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| In-line AC spark test & conductor DC resistance | 100 % spark-tested at 1.5–3.0 kV; DC resistance per SAE J1128 Table 1 | 100 % of spools |
| Sample tests | ||
| -40 °C cold bend & 1.0 kV wet dielectric test | No insulation cracks after 4 h at -40 °C followed by 1 kV saltwater immersion | Every lot |
| SAE J1128 3000-hour thermal ageing & fluid immersion | Retains dielectric strength after 3000 h at +85 °C and hot oil/fuel immersion | Type qualification |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.