Contact

GX-SERIES (GX036D) MSHA Subgrouping Mining Optical CableGX-SERIES (GX036D) MSHA-approved all-dielectric tight-buffered subgrouping optical cable for underground mining and industrial backbones, with 6 aramid-reinforced 6-fibre sub-units (36F) around a central FRP rod and an interlocked MSHA jacket.

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 across -40 to +85 °C.

Flame-retardant
Oil-resistant
Anti-torsion braid
Approved
Order designation
GX-SERIES (GX036D) 36F (6×6F) Subgrouping
Outer Ø ≈
14.5 mm
Net weight ≈
192 kg/km
Tensile rating ≈
3.6 kN
Core / stranding
900 µm tight-buffered + Aramid
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
Optical
All-dielectric mining optical cable
Operating temp.
-40 to +85 °C
Continuous mining & industrial duty
Min. bend radius
10 × OD
Fixed installation / dynamic routing
Core / conductor
12–72F 900 µm
900 µm tight-buffered sub-cables
Outer protection
D-Jacket MSHA
Interlocked MSHA flame-retardant PVC
Standard
MSHA / GX-Series
MSHA 30 CFR 7.408 / MIL-PRF-85045

Typical values for this cable type, based on MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 — confirmed in the datasheet and quotation for your order.

Application fit

Is GX-SERIES (GX036D) right for your machine?

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 across -40 to +85 °C.

Mine roadway & tunnel wall hangers

Suitable

Engineered for underground mining shafts, galleries and tunnel infrastructure per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045.

Fixed installation

Suitable

Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 10 × OD.

Free-hanging vertical run

Suitable

Supports inclined roadway and vertical mine shaft suspension within rated kN load across -40 to +85 °C.

Typical machinesMining & TunnellingUnderground Coal & Hard-Rock MiningOpen-Cast Excavators, Draglines & ShovelsVertical Mine Shafts, Hoists & BoreholesTunneling, Mineral Processing & Slurry Plants

Construction

Layer by layer

Shown: GX-SERIES (GX036D) (MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045) featuring central dielectric member, sub-cable units (6×6f subgrouping) and interlocked outer jacket (d-jacket) (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Central Dielectric MemberFlexible central rod stabilizing helically stranded sub-cables
2Sub-Cable Units (6×6F Subgrouping)Six independent sub-cables with 900 µm tight-buffered fibres & aramid yarn
3Peripheral Aramid ReinforcementHeavy outer layer of high-modulus aramid yarns for pulling tension
4Interlocked Outer Jacket (D-Jacket)Pressure-extruded MSHA-approved jacket interlocked with sub-unit interstices

GX-SERIES (GX036D) — Standard Mining Execution

Built to MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 with central dielectric member and interlocked outer jacket (d-jacket)

GX-SERIES (GX036D) — Custom Drum Length & Gland Kit

Available in custom shaft/roadway drum lengths or pre-terminated assemblies

GX-SERIES (GX036D) — Routine & Flame Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
Optical (MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045)
Core / conductor construction
Central Dielectric Member — Flexible central rod stabilizing helically stranded sub-cables
Primary dielectric / buffering
Sub-Cable Units (6×6F Subgrouping) — Six independent sub-cables with 900 µm tight-buffered fibres & aramid yarn

Thermal

Continuous operating temperature
-40 to +85 °C (mining & industrial service)
Short-circuit / peak thermal rating
Verified thermal stability per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Interlocked Outer Jacket (D-Jacket) — Pressure-extruded MSHA-approved jacket interlocked with sub-unit interstices
Minimum bending radius
10 × OD
Crush, impact & abrasion duty
Heavy-duty mining rock-cut, impact and tensile protection per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045

Resistance

Flame retardancy & mine fire safety
Self-extinguishing / flame-retardant mining jacket per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045
Mine water, oil & chemical resistance
Resistant to acidic mine water, hydraulic oils and abrasion per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045
Flame & environmental test standards
IEC 60332 / MSHA / EN 60794 / IEC 60228
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
GX-SERIES (GX036D)
Sheath colour & metre marking
Continuous metre-marked orange mining outer sheath
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard GX-SERIES (GX036D) mining & industrial configurations

Manufactured to MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 for underground mining, open-cast excavation, shaft and heavy industrial systems.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
GX-SERIES (GX036D) Construction Schedule (-40 to +85 °C)
GX-SERIES (GX024D) 24F (4×6F) Subgrouping24 × SM/MM (4 × 6F Sub-Units)900 µm tight-buffered + Aramid12.21382.7122
GX-SERIES (GX036D) 36F (6×6F) Subgrouping36 × SM/MM (6 × 6F Sub-Units)900 µm tight-buffered + Aramid14.51923.6145
GX-SERIES (GX072D) 72F (6×12F) Subgrouping72 × SM/MM (6 × 12F Sub-Units)900 µm tight-buffered + Aramid18.83104.5190
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045)DC resistance at 20 °C / optical attenuation and outer diameter within MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045)Zero dielectric breakdown and verified insulation resistance over full production lengthEvery manufactured drum length
Sample tests
Flame propagation, mechanical crush & thermal ageing qualification (MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045)Verified flame retardancy, mechanical integrity and thermal endurance across -40 to +85 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

MSHA / GX-Series CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX GX-SERIES (GX036D) MSHA / GX-Series Optical CE
Delivery form
Heavy-duty export fumigated wooden drums or steel mine reels
Standard lengths
500 m, 1,000 m or custom continuous shaft/reeling lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-24
Updated
2026-10-24

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define GX-SERIES (GX036D) (GX-SERIES (GX036D) MSHA Subgrouping Mining Optical Cable)?
GX-SERIES (GX036D) (GX-SERIES (GX036D) MSHA Subgrouping Mining Optical Cable) is manufactured in accordance with MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 for Optical duty over -40 to +85 °C. Its 4-layer construction comprises Central Dielectric Member, Sub-Cable Units (6×6F Subgrouping) and Interlocked Outer Jacket (D-Jacket).
What is the minimum bending radius and operating temperature range for GX-SERIES (GX036D)?
The minimum bending radius for GX-SERIES (GX036D) is 10 × OD across its continuous operating temperature range of -40 to +85 °C, ensuring mechanical and dielectric reliability in mining and heavy industrial service.
How are the concentric layers of GX-SERIES (GX036D) arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Central Dielectric Member (Flexible central rod stabilizing helically stranded sub-cables); (02) Sub-Cable Units (6×6F Subgrouping) (Six independent sub-cables with 900 µm tight-buffered fibres & aramid yarn); (03) Peripheral Aramid Reinforcement (Heavy outer layer of high-modulus aramid yarns for pulling tension); (04) Interlocked Outer Jacket (D-Jacket) (Pressure-extruded MSHA-approved jacket interlocked with sub-unit interstices).
What factory test certificates are supplied with GX-SERIES (GX036D)?
Every production drum of GX-SERIES (GX036D) undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for GX-SERIES (GX036D)

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

GX-SERIES (GX036D) MSHA Subgrouping Mining Optical Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote