Mine roadway & tunnel wall hangers
Engineered for underground mining shafts, galleries and tunnel infrastructure per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 across -40 to +85 °C.
Typical values for this cable type, based on MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 across -40 to +85 °C.
Engineered for underground mining shafts, galleries and tunnel infrastructure per MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045.
Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 10 × OD.
Supports inclined roadway and vertical mine shaft suspension within rated kN load across -40 to +85 °C.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: GX-SERIES (GX036D) (MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045) featuring central dielectric member, sub-cable units (6×6f subgrouping) and interlocked outer jacket (d-jacket) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Central Dielectric Member | Flexible central rod stabilizing helically stranded sub-cables |
| 2 | Sub-Cable Units (6×6F Subgrouping) | Six independent sub-cables with 900 µm tight-buffered fibres & aramid yarn |
| 3 | Peripheral Aramid Reinforcement | Heavy outer layer of high-modulus aramid yarns for pulling tension |
| 4 | Interlocked Outer Jacket (D-Jacket) | Pressure-extruded MSHA-approved jacket interlocked with sub-unit interstices |
Built to MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 with central dielectric member and interlocked outer jacket (d-jacket)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| GX-SERIES (GX036D) Construction Schedule (-40 to +85 °C) | |||||||
| GX-SERIES (GX024D) 24F (4×6F) Subgrouping | 24 × SM/MM (4 × 6F Sub-Units) | 900 µm tight-buffered + Aramid | 12.2 | 138 | 2.7 | 122 | |
| GX-SERIES (GX036D) 36F (6×6F) Subgrouping | 36 × SM/MM (6 × 6F Sub-Units) | 900 µm tight-buffered + Aramid | 14.5 | 192 | 3.6 | 145 | |
| GX-SERIES (GX072D) 72F (6×12F) Subgrouping | 72 × SM/MM (6 × 12F Sub-Units) | 900 µm tight-buffered + Aramid | 18.8 | 310 | 4.5 | 190 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 24 × SM/MM (4 × 6F Sub-Units) | 0.40 | ≤0.4 / 0.3 dB/km @ 1310/1550 nm | -40 to +85 °C |
| 36 × SM/MM (6 × 6F Sub-Units) | 0.40 | ≤0.4 / 0.3 dB/km @ 1310/1550 nm | -40 to +85 °C |
| 72 × SM/MM (6 × 12F Sub-Units) | 0.40 | ≤0.4 / 0.3 dB/km @ 1310/1550 nm | -40 to +85 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045) | DC resistance at 20 °C / optical attenuation and outer diameter within MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (MSHA 30 CFR 7.408 / TIA-568 / MIL-PRF-85045) | Verified flame retardancy, mechanical integrity and thermal endurance across -40 to +85 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.