Immersion & wet locations
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Product
FMXCAT5 600 V Subsea Cat 5e Ethernet & Power Aramid-Reinforced Composite Cable featuring 24 awg stranded cat5e data pairs (4×2) and low-friction polyurethane (pur) jacket (ISO/IEC 11801 Cat 5e / Subsea, 600 V, -30 to +80 °C).
Typical values for this cable type, based on ISO/IEC 11801 Cat 5e & Subsea Electro-Mechanical Composite Specification — confirmed in the datasheet and quotation for your order.
Application fit
FMXCAT5 600 V Subsea Cat 5e Ethernet & Power Aramid-Reinforced Composite Cable featuring 24 awg stranded cat5e data pairs (4×2) and low-friction polyurethane (pur) jacket (ISO/IEC 11801 Cat 5e / Subsea, 600 V, -30 to +80 °C).
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling
Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.
UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.
Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.
Use M23 Servo AssemblyConstruction
Shown: FMXCAT5 600V (ISO/IEC 11801 Cat 5e & Subsea Electro-Mechanical Composite Specification) featuring 24 awg stranded cat5e data pairs (4×2), 600 v power supply conductors (12-20 awg) and low-friction polyurethane (pur) jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | 24 AWG Stranded Cat5e Data Pairs (4×2) | Four twisted pairs with water-resistant polyolefin insulation |
| 2 | 600 V Power Supply Conductors (12-20 AWG | Stranded copper power conductors feeding subsea profilers & ROVs |
| 3 | Water-Blocked Core & Aramid Braid (2,400 | Full water-blocking compound + braided aramid strength member |
| 4 | Low-Friction Polyurethane (PUR) Jacket | Smooth abrasion-resistant PUR outer sheath for profiling winches |
Built to ISO/IEC 11801 Cat 5e & Subsea Electro-Mechanical Composite Specification with 24 awg stranded cat5e data pairs (4×2) and low-friction polyurethane (pur) jacket
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to ISO/IEC 11801 Cat 5e & Subsea Electro-Mechanical Composite Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| FMXCAT5 600V Construction Schedule (−30…+80 °C) | |||||||
| FMXCAT5 600V Coax / Cat5e | Coax (39/40/50/75 Ω) or 4Pr Cat5e + Power | Stranded SnCu + Foam PE/FEP + Armour/Aramid | 8.2 | 245 | 42.7 | 120 | |
| FMXCAT5 600V Composite B | Heavy Coax / 64-Ch Digital Bus + Power | Stranded SnCu + Low-Loss Dielectric + Strength | 11.5 | 485 | 71.2 | 170 | |
| FMXCAT5 600V Array / Trunk C | Multi-Ch Digital Streamer / 255-Ch Bus | Redundant Telemetry + Aramid + PUR Jacket | 44.5 | 1,620 | 95.0 | 445 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| Coax (39/40/50/75 Ω) or 4Pr Cat5e + Power | 18.50 | 600 V (High-Speed) | −30…+80 °C |
| Heavy Coax / 64-Ch Digital Bus + Power | 11.20 | 600 V (Deep-Tow/Array) | −30…+80 °C |
| Multi-Ch Digital Streamer / 255-Ch Bus | 6.80 | 600 V (Full Array) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (ISO/IEC 11801 Cat 5e & Subsea Electro-Mechanical Composite Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within ISO/IEC 11801 Cat 5e & Subsea Electro-Mechanical Composite Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ISO/IEC 11801 Cat 5e & Subsea Electro-Mechanical Composite Specification) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (ISO/IEC 11801 Cat 5e & Subsea Electro-Mechanical Composite Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.