Fixed installation
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
Product
FMGCG & FMGCH 60/250 V DIN 89159 HEPR Shipboard Telecommunication & Signal Cable (DIN 89159 / IEC 60092-375) engineered for 60/250 V service across -40 to +90 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on DIN 89159 & IEC 60092-375 / IEC 60092-376 — confirmed in the datasheet and quotation for your order.
Application fit
FMGCG & FMGCH 60/250 V DIN 89159 HEPR Shipboard Telecommunication & Signal Cable (DIN 89159 / IEC 60092-375) engineered for 60/250 V service across -40 to +90 °C (min. bend radius 6 × OD).
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
SHF1/SHF2 or IEEE 1580 Type P outer sheath resists drilling mud, hydrocarbons, salt spray and UV exposure.
Compact twisted pairs and numbered cores route cleanly into DCS/PLC cabinets, Ex-i barriers and bridge consoles.
Tinned copper, bronze or galvanized steel wire braid armour protects signal integrity in hazardous offshore zones.
Fixed shipboard and offshore instrumentation cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: FMGCG & FMGCH 60/250 V (DIN 89159 HEPR) (DIN 89159 & IEC 60092-375 / IEC 60092-376) featuring hepr star-quad units (4×4×0.75 mm²), extruded elastomeric inner covering and 5gm3 polychloroprene / shf1 outer jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | HEPR Star-Quad Units (4×4×0.75 mm²) | Four star-quads of stranded copper with HEPR (3GI3) rubber insulation |
| 2 | Extruded Elastomeric Inner Covering | Inner bedding sheath filling interstices between star-quads |
| 3 | Copper Wire Braid Screen & Armour (C) | High-coverage bare copper wire braid for EMI shielding and protection |
| 4 | 5GM3 Polychloroprene / SHF1 Outer Jacket | Oil-resistant polychloroprene (FMGCG) or halogen-free SHF1 (FMGCH) sheath |
Built to DIN 89159 & IEC 60092-375 / IEC 60092-376 with hepr star-quad units (4×4×0.75 mm²) and 5gm3 polychloroprene / shf1 outer jacket
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to DIN 89159 & IEC 60092-375 / IEC 60092-376 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| FMGCG & FMGCH 60/250 V (DIN 89159 HEPR) Construction Schedule (−40…+90 °C) | |||||||
| FMGCG & FMGCH 60/250 V 2×2×0.75 mm² | 2 × 2 × 0.75 mm² (2Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 11.4 | 195 | 1.2 | 70 | |
| FMGCG & FMGCH 60/250 V 4×2×1.0 mm² | 4 × 2 × 1.0 mm² (4Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 15.6 | 365 | 2.4 | 95 | |
| FMGCG & FMGCH 60/250 V 8×2×1.5 mm² | 8 × 2 × 1.5 mm² (8Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 22.8 | 760 | 4.8 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.75 mm² (2Pr) | 26.00 | 60/250 V (≤60 nF/km) | −40…+90 °C |
| 4 × 2 × 1.0 mm² (4Pr) | 19.50 | 60/250 V (≤65 nF/km) | −40…+90 °C |
| 8 × 2 × 1.5 mm² (8Pr) | 13.30 | 60/250 V (≤75 nF/km) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN 89159 & IEC 60092-375 / IEC 60092-376) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN 89159 & IEC 60092-375 / IEC 60092-376 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN 89159 & IEC 60092-375 / IEC 60092-376) | Zero dielectric breakdown and verified insulation resistance for 60/250 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (DIN 89159 & IEC 60092-375 / IEC 60092-376) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.