Fixed installation
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
Product
FM2XCH & FM2XCH-TP 150/250 V DIN 89159 & IEC 60092-376 XLPE-Insulated Twisted-Pair/Quad Copper-Braid Screened SHF1 Halogen-Free Shipboard Communication & Signal Cable (DIN 89159 / IEC 60092-376, 150/250 V, -40 to +90 °C).
Typical values for this cable type, based on DIN 89159 & IEC 60092-376 / IEC 60092-360 SHF1 — confirmed in the datasheet and quotation for your order.
Application fit
FM2XCH & FM2XCH-TP 150/250 V DIN 89159 & IEC 60092-376 XLPE-Insulated Twisted-Pair/Quad Copper-Braid Screened SHF1 Halogen-Free Shipboard Communication & Signal Cable (DIN 89159 / IEC 60092-376, 150/250 V, -40 to +90 °C).
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
SHF1/SHF2 or IEEE 1580 Type P outer sheath resists drilling mud, hydrocarbons, salt spray and UV exposure.
Compact twisted pairs and numbered cores route cleanly into DCS/PLC cabinets, Ex-i barriers and bridge consoles.
Tinned copper, bronze or galvanized steel wire braid armour protects signal integrity in hazardous offshore zones.
Fixed shipboard and offshore instrumentation cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: FM2XCH & FM2XCH-TP 150/250 V (DIN 89159) (DIN 89159 & IEC 60092-376 / IEC 60092-360 SHF1) featuring stranded copper twisted pairs (7×2×0.75 mm²), halogen-free extruded inner covering and grey shf1 zero-halogen outer sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Copper Twisted Pairs (7×2×0.75 | IEC 60228 Class 2 / Class 5 copper conductors with XLPE insulation |
| 2 | Halogen-Free Extruded Inner Covering | Flame-retardant halogen-free inner bedding over cabled pairs |
| 3 | Copper Wire Braid Screen & Armour (C) | High-coverage copper wire braid for collective EMC screening |
| 4 | Grey SHF1 Zero-Halogen Outer Sheath | Thermoplastic polyolefin low-smoke halogen-free jacket (DIN 89159) |
Built to DIN 89159 & IEC 60092-376 / IEC 60092-360 SHF1 with stranded copper twisted pairs (7×2×0.75 mm²) and grey shf1 zero-halogen outer sheath
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to DIN 89159 & IEC 60092-376 / IEC 60092-360 SHF1 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| FM2XCH & FM2XCH-TP 150/250 V (DIN 89159) Construction Schedule (−40…+90 °C) | |||||||
| FM2XCH 2×2×0.75 mm² | 2 × 2 × 0.75 mm² (2Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 11.4 | 195 | 1.2 | 70 | |
| FM2XCH 4×2×1.0 mm² | 4 × 2 × 1.0 mm² (4Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 15.6 | 365 | 2.4 | 95 | |
| FM2XCH 8×2×1.5 mm² | 8 × 2 × 1.5 mm² (8Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 22.8 | 760 | 4.8 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.75 mm² (2Pr) | 26.00 | 150/250 V (≤60 nF/km) | −40…+90 °C |
| 4 × 2 × 1.0 mm² (4Pr) | 19.50 | 150/250 V (≤65 nF/km) | −40…+90 °C |
| 8 × 2 × 1.5 mm² (8Pr) | 13.30 | 150/250 V (≤75 nF/km) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN 89159 & IEC 60092-376 / IEC 60092-360 SHF1) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN 89159 & IEC 60092-376 / IEC 60092-360 SHF1 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN 89159 & IEC 60092-376 / IEC 60092-360 SHF1) | Zero dielectric breakdown and verified insulation resistance for 150/250 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (DIN 89159 & IEC 60092-376 / IEC 60092-360 SHF1) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.