Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
FM088095 Series 1000 V Stainless-Steel or Aramid-Braided Water-Blocked Commercial Diver Communication Cable (ASTM B3 / D1248, 0.6/1 kV, -30 °C to +80 °C, min. bend radius 8 × OD).
Typical values for this cable type, based on ASTM B3 / ASTM D1248 / IMCA D 014 Diver Comms Standard — confirmed in the datasheet and quotation for your order.
Application fit
FM088095 Series 1000 V Stainless-Steel or Aramid-Braided Water-Blocked Commercial Diver Communication Cable (ASTM B3 / D1248, 0.6/1 kV, -30 °C to +80 °C, min. bend radius 8 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: FM088095 (ASTM B3 / ASTM D1248 / IMCA D 014 Diver Comms Standard) featuring spiral-4 conductors (4×20 awg 7/28), astm d1248 pe insulation (blue & black) and marine pvc / polyurethane outer jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Spiral-4 Conductors (4×20 AWG 7/28) | ASTM B3 stranded annealed bare copper in star-quad (Spiral-4) geometry |
| 2 | ASTM D1248 PE Insulation (Blue & Black) | 1,000 V polyethylene insulation color-coded Blue & Black with numbered markers |
| 3 | Solid Extruded PE Inner Bedding | Solid extruded bedding layer resisting hydrostatic squeeze (or flexible waterblock) |
| 4 | Braided Stainless Steel / Aramid Armor | Braided stainless-steel armor (250 lbs on FM088095) or Aramid braid (up to 750 lbs) |
| 5 | Marine PVC / Polyurethane Outer Jacket | Tear- and abrasion-resistant subsea outer jacket (Ø 9.1–10.9 mm) |
Built to ASTM B3 / ASTM D1248 / IMCA D 014 Diver Comms Standard with spiral-4 conductors (4×20 awg 7/28) and marine pvc / polyurethane outer jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to ASTM B3 / ASTM D1248 / IMCA D 014 Diver Comms Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| FM088095 Construction Schedule (−30…+80 °C) | |||||||
| FM088095 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| FM088095 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| FM088095 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −30…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −30…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ASTM B3 / ASTM D1248 / IMCA D 014 Diver Comms Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within ASTM B3 / ASTM D1248 / IMCA D 014 Diver Comms Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ASTM B3 / ASTM D1248 / IMCA D 014 Diver Comms Standard) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (ASTM B3 / ASTM D1248 / IMCA D 014 Diver Comms Standard) | Verified submersion integrity, tensile load and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.