Immersion & wet locations
Engineered for deep-water hydrostatic immersion and marine deployment per IEC 60502-1 / ISO 13628-5 / DNV-ST-E402.
Product
FEVE 1.8/3 (3.6) kV subsea electro-optical umbilical cable integrating 3 medium-voltage power conductors, single-mode optical fibers, contra-helical double galvanized steel wire armour and an HDPE outer sheath.
Typical values for this cable type, based on IEC 60502-1 / ISO 13628-5 / DNV-ST-E402 — confirmed in the datasheet and quotation for your order.
Application fit
FEVE 1.8/3 (3.6) kV subsea electro-optical umbilical cable integrating 3 medium-voltage power conductors, single-mode optical fibers, contra-helical double galvanized steel wire armour and an HDPE outer sheath.
Engineered for deep-water hydrostatic immersion and marine deployment per IEC 60502-1 / ISO 13628-5 / DNV-ST-E402.
Suitable for subsea winch deployment, LARS sheaves and vertical marine suspension within 12–20 × OD.
Verified for fixed subsea structure routing, deck jumpers and seabed interconnections.
Not intended for high-cycle dry factory drag chains; select a dedicated拖链/drag-chain cable for indoor automation.
Subsea ROV Main Lift UmbilicalConstruction
Shown: FEVE 1.8/3 kV (IEC 60502-1 / ISO 13628-5 / DNV-ST-E402) featuring stranded copper power & pilot conductors, polyethylene (pe / xlpe) power & pilot insulation and high-density polyethylene (hdpe) subsea outer sheath (6-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Copper Power & Pilot Conductors | Three compacted circular stranded copper phase conductors (3 x 70–240 mm²) plus two 1.5 mm² copper pilot/monitoring coresIEC 60502-1 / ISO 13628-5 / DNV-ST-E402 |
| 2 | Polyethylene (PE / XLPE) Power & Pilot Insulation | Extruded heavy-wall polyethylene insulation on phase cores (Brown, Black, Grey, 1.8/3 (3.6) kV) and pilot coresIEC 60502-1 / ISO 13628-5 / DNV-ST-E402 |
| 3 | Laser-Welded Stainless Steel Optical Tube (12F SM) | Hermetically sealed stainless steel tube containing 12 single-mode (ITU-T G.652.D) optical fibers in thixotropic gel with PE jacketIEC 60502-1 / ISO 13628-5 / DNV-ST-E402 |
| 4 | Petrolatum-Filled Interstices & PE Inner Sheath | Water-blocking petrolatum compound filling core interstices beneath an extruded polyethylene (PE) inner bedding sheathIEC 60502-1 / ISO 13628-5 / DNV-ST-E402 |
| 5 | Contra-Helical Double Galvanized Steel Wire Armour (DWA) | Two layers of heavy galvanized steel round wires applied in counter-helical lay for high tensile and seabed impact protectionIEC 60502-1 / ISO 13628-5 / DNV-ST-E402 |
| 6 | High-Density Polyethylene (HDPE) Subsea Outer Sheath | Abrasion- and UV-resistant black high-density polyethylene (HDPE) outer serving for seabed laying and shore landingsIEC 60502-1 / ISO 13628-5 / DNV-ST-E402 |
Built to IEC 60502-1 / ISO 13628-5 / DNV-ST-E402 with stranded copper power & pilot conductors and high-density polyethylene (hdpe) subsea outer sheath
Available in continuous subsea winch lengths or factory-moulded / socket-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, optical & hydrostatic test report
Technical data
Sizes
Manufactured to IEC 60502-1 / ISO 13628-5 / DNV-ST-E402 for deep-water ROV, towed array, mooring and subsea production systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight in air ≈ kg/km | Breaking load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| FEVE 1.8/3 kV Subsea Construction Schedule (−40…+90 °C) | |||||||
| FEVE 1.8/3 kV 3×10 mm² + 12 FO | 3 × 10 mm² + 12 × SM FO | Class 5 Cu + FIMT | 28.5 | 1,680 | 145.0 | 345 | |
| FEVE 1.8/3 kV 3×16 mm² + 12 FO | 3 × 16 mm² + 12 × SM FO | Class 5 Cu + FIMT | 31.8 | 2,120 | 185.0 | 385 | |
| FEVE 1.8/3 kV 3×25 mm² + 12 FO | 3 × 25 mm² + 12 × SM FO | Class 5 Cu + FIMT | 35.4 | 2,690 | 230.0 | 425 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 10 mm² + 12 × SM FO | 1.95 | 1.8/3 (3.6) kV / 65 A | −40…+90 °C |
| 3 × 16 mm² + 12 × SM FO | 1.24 | 1.8/3 (3.6) kV / 88 A | −40…+90 °C |
| 3 × 25 mm² + 12 × SM FO | 0.80 | 1.8/3 (3.6) kV / 115 A | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR & dimensional verification (IEC 60502-1 / ISO 13628-5 / DNV-ST-E402) | Electrical resistance, optical attenuation at 1310/1550 nm and OD within IEC 60502-1 / ISO 13628-5 / DNV-ST-E402 tolerances | Every manufactured drum / assembly |
| High-voltage dielectric & insulation resistance test (IEC 60502-1 / ISO 13628-5 / DNV-ST-E402) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / assembly |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & bend-over-sheave qualification (IEC 60502-1 / ISO 13628-5 / DNV-ST-E402) | Verified structural and transmission integrity under deep-water pressure and tensile cycling across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.