Contact

FEVE 1.8/3 kV Armoured Subsea Umbilical CableIEC 60502-1 / ISO 13628-5 · 1.8/3 (3.6) kV · Contra-helically armoured subsea

FEVE 1.8/3 (3.6) kV subsea electro-optical umbilical cable integrating 3 medium-voltage power conductors, single-mode optical fibers, contra-helical double galvanized steel wire armour and an HDPE outer sheath.

Water-resistant
Anti-torsion braid
EMC screen
Oil-resistant
Order designation
FEVE 1.8/3 kV 3×10 mm² + 12 FO
Outer Ø ≈
28.5 mm
Weight in air ≈
1,680 kg/km
Breaking load ≈
145.0 kN
Core / stranding
Class 5 Cu + FIMT
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1.8/3 (3.6) kV
3-phase MV power & optical data
Operating temp.
−40…+90 °C
Continuous subsea & deck service
Min. bend radius
12–20 × OD
Static routing / dynamic sheave
Core / conductor
3×MV Cu + FO
Class 5 Cu + FIMT optical core
Outer protection
2×GIPS + HDPE
Double GIPS wire armour + HDPE
Standard
ISO 13628-5
IEC 60502-1 / ISO 13628-5 / DNV-ST-E402

Typical values for this cable type, based on IEC 60502-1 / ISO 13628-5 / DNV-ST-E402 — confirmed in the datasheet and quotation for your order.

Application fit

Is FEVE 1.8/3 kV right for your machine?

FEVE 1.8/3 (3.6) kV subsea electro-optical umbilical cable integrating 3 medium-voltage power conductors, single-mode optical fibers, contra-helical double galvanized steel wire armour and an HDPE outer sheath.

Immersion & wet locations

Suitable

Engineered for deep-water hydrostatic immersion and marine deployment per IEC 60502-1 / ISO 13628-5 / DNV-ST-E402.

Vertical / spreader reel

Suitable

Suitable for subsea winch deployment, LARS sheaves and vertical marine suspension within 12–20 × OD.

Offshore platform & shipboard deck trays

Suitable

Verified for fixed subsea structure routing, deck jumpers and seabed interconnections.

Energy chain / drag chain

Not suitable

Not intended for high-cycle dry factory drag chains; select a dedicated拖链/drag-chain cable for indoor automation.

Subsea ROV Main Lift Umbilical
Typical machinesMarine & Offshore CableSubsea ROV, AUV & Towed Array SystemsOffshore Oil, Gas & Subsea Production UmbilicalsOceanographic Mooring & Deep-Water TelemetryNaval Defence, Hydrographic & Sonar Arrays

Construction

Layer by layer

Shown: FEVE 1.8/3 kV (IEC 60502-1 / ISO 13628-5 / DNV-ST-E402) featuring stranded copper power & pilot conductors, polyethylene (pe / xlpe) power & pilot insulation and high-density polyethylene (hdpe) subsea outer sheath (6-layer construction).

123456
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded Copper Power & Pilot ConductorsThree compacted circular stranded copper phase conductors (3 x 70–240 mm²) plus two 1.5 mm² copper pilot/monitoring coresIEC 60502-1 / ISO 13628-5 / DNV-ST-E402
2Polyethylene (PE / XLPE) Power & Pilot InsulationExtruded heavy-wall polyethylene insulation on phase cores (Brown, Black, Grey, 1.8/3 (3.6) kV) and pilot coresIEC 60502-1 / ISO 13628-5 / DNV-ST-E402
3Laser-Welded Stainless Steel Optical Tube (12F SM)Hermetically sealed stainless steel tube containing 12 single-mode (ITU-T G.652.D) optical fibers in thixotropic gel with PE jacketIEC 60502-1 / ISO 13628-5 / DNV-ST-E402
4Petrolatum-Filled Interstices & PE Inner SheathWater-blocking petrolatum compound filling core interstices beneath an extruded polyethylene (PE) inner bedding sheathIEC 60502-1 / ISO 13628-5 / DNV-ST-E402
5Contra-Helical Double Galvanized Steel Wire Armour (DWA)Two layers of heavy galvanized steel round wires applied in counter-helical lay for high tensile and seabed impact protectionIEC 60502-1 / ISO 13628-5 / DNV-ST-E402
6High-Density Polyethylene (HDPE) Subsea Outer SheathAbrasion- and UV-resistant black high-density polyethylene (HDPE) outer serving for seabed laying and shore landingsIEC 60502-1 / ISO 13628-5 / DNV-ST-E402

FEVE 1.8/3 kV — Standard Subsea Execution

Built to IEC 60502-1 / ISO 13628-5 / DNV-ST-E402 with stranded copper power & pilot conductors and high-density polyethylene (hdpe) subsea outer sheath

FEVE 1.8/3 kV — Custom Length & Termination

Available in continuous subsea winch lengths or factory-moulded / socket-terminated assemblies

FEVE 1.8/3 kV — Hydrostatic & Factory Certified

Supplied with EN 10204 3.1 routine electrical, optical & hydrostatic test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60502-1 / ISO 13628-5 / DNV-ST-E402. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
1.8/3 (3.6) kV (IEC 60502-1 / ISO 13628-5 / DNV-ST-E402)
Core / conductor construction
Stranded Copper Power & Pilot Conductors — Three compacted circular stranded copper phase conductors (3 x 70–240 mm²) plus two 1.5 mm² copper pilot/monitoring cores
Primary dielectric / buffering
Polyethylene (PE / XLPE) Power & Pilot Insulation — Extruded heavy-wall polyethylene insulation on phase cores (Brown, Black, Grey, 1.8/3 (3.6) kV) and pilot cores

Thermal

Continuous operating temperature
−40…+90 °C (subsea immersion & marine deck service)
Storage & transport temperature
−40…+80 °C on marine export reel

Mechanical

Outer protection / armouring
High-Density Polyethylene (HDPE) Subsea Outer Sheath — Abrasion- and UV-resistant black high-density polyethylene (HDPE) outer serving for seabed laying and shore landings
Minimum bending radius
12–20 × OD
Hydrostatic depth rating
Up to 6,000 m water depth (60 MPa hydrostatic pressure)

Resistance

Seawater, hydrolysis & oil resistance
Continuous seawater immersion, hydraulic fluids and marine UV per IEC 60502-1 / ISO 13628-5 / DNV-ST-E402
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60502-1 / ISO 13628-5 / DNV-ST-E402
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
FEVE 1.8/3 kV
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard FEVE 1.8/3 kV subsea configurations

Manufactured to IEC 60502-1 / ISO 13628-5 / DNV-ST-E402 for deep-water ROV, towed array, mooring and subsea production systems.

Dimensions, breaking load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Weight in air ≈
kg/km
Breaking load
kN ≈
Min. bend R
mm
Enquiry
FEVE 1.8/3 kV Subsea Construction Schedule (−40…+90 °C)
FEVE 1.8/3 kV 3×10 mm² + 12 FO3 × 10 mm² + 12 × SM FOClass 5 Cu + FIMT28.51,680145.0345
FEVE 1.8/3 kV 3×16 mm² + 12 FO3 × 16 mm² + 12 × SM FOClass 5 Cu + FIMT31.82,120185.0385
FEVE 1.8/3 kV 3×25 mm² + 12 FO3 × 25 mm² + 12 × SM FOClass 5 Cu + FIMT35.42,690230.0425
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fibre counts, armour wire grades and factory-moulded subsea terminations available per IEC 60502-1 / ISO 13628-5 / DNV-ST-E402.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR & dimensional verification (IEC 60502-1 / ISO 13628-5 / DNV-ST-E402)Electrical resistance, optical attenuation at 1310/1550 nm and OD within IEC 60502-1 / ISO 13628-5 / DNV-ST-E402 tolerancesEvery manufactured drum / assembly
High-voltage dielectric & insulation resistance test (IEC 60502-1 / ISO 13628-5 / DNV-ST-E402)Zero dielectric breakdown and verified insulation resistance over full lengthEvery manufactured drum / assembly
Sample tests
Hydrostatic pressure, tensile breaking load & bend-over-sheave qualification (IEC 60502-1 / ISO 13628-5 / DNV-ST-E402)Verified structural and transmission integrity under deep-water pressure and tensile cycling across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ISO 13628-5 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX FEVE 1.8/3 kV ISO 13628-5 1.8/3 (3.6) kV SUBSEA CE
Delivery form
Heavy-duty marine export wooden/steel drums or pressure-tested coiled assemblies
Standard lengths
Custom continuous winch lengths up to 6,000 m or cut-to-length assemblies
MOQ
100 m (standard configurations) · 500 m (custom umbilical builds)
Lead time
3–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-22
Updated
2026-10-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define FEVE 1.8/3 kV (FEVE 1.8/3 kV Armoured Subsea Umbilical Cable)?
FEVE 1.8/3 kV (FEVE 1.8/3 kV Armoured Subsea Umbilical Cable) is engineered in accordance with IEC 60502-1 / ISO 13628-5 / DNV-ST-E402 for 1.8/3 (3.6) kV service over -40 °C to +90 °C. Its 6-layer construction comprises stranded copper power & pilot conductors, polyethylene (pe / xlpe) power & pilot insulation and high-density polyethylene (hdpe) subsea outer sheath.
What is the minimum bending radius and operating temperature range for FEVE 1.8/3 kV?
The minimum bending radius for FEVE 1.8/3 kV is 12–20 × OD across its continuous operating temperature range of -40 °C to +90 °C, ensuring mechanical, optical and dielectric stability during subsea deployment and winch handling.
How are the concentric layers of FEVE 1.8/3 kV arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded Copper Power & Pilot Conductors (Three compacted circular stranded copper phase conductors (3 x 70–240 mm²) plus two 1.5 mm² copper pilot/monitoring cores); (02) Polyethylene (PE / XLPE) Power & Pilot Insulation (Extruded heavy-wall polyethylene insulation on phase cores (Brown, Black, Grey, 1.8/3 (3.6) kV) and pilot cores); (03) Laser-Welded Stainless Steel Optical Tube (12F SM) (Hermetically sealed stainless steel tube containing 12 single-mode (ITU-T G.652.D) optical fibers in thixotropic gel with PE jacket); (04) Petrolatum-Filled Interstices & PE Inner Sheath (Water-blocking petrolatum compound filling core interstices beneath an extruded polyethylene (PE) inner bedding sheath); (05) Contra-Helical Double Galvanized Steel Wire Armour (DWA) (Two layers of heavy galvanized steel round wires applied in counter-helical lay for high tensile and seabed impact protection); (06) High-Density Polyethylene (HDPE) Subsea Outer Sheath (Abrasion- and UV-resistant black high-density polyethylene (HDPE) outer serving for seabed laying and shore landings).
What factory test certificates are supplied with FEVE 1.8/3 kV?
Every production drum or assembly of FEVE 1.8/3 kV undergoes routine electrical/optical continuity, high-voltage dielectric and dimensional testing per IEC 60502-1 / ISO 13628-5 / DNV-ST-E402, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for FEVE 1.8/3 kV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

FEVE 1.8/3 kV Armoured Subsea Umbilical Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote