Free-hanging vertical run
Class 5 flexible copper cores and cross-linked EPR / silicone / PCP rubber jackets survive >10,000–18,000 yaw drip-loop torsion cycles.
Product
FDGG / FDGU 1.8/3 kV (0.6/1 kV) Ultra-Cold (-55 °C to +125 °C) Silicone / PUR Wind Turbine Torsion Cable (TICW/01 / GB/T 29631) engineered for 1.8/3 kV (0.6/1 kV) wind turbine service across -55 to +125 °C (min. bend radius 5 × OD).
Typical values for this cable type, based on TICW/01 & GB/T 29631 FDGG (Silicone/Silicone) & FDGU (Silicone/PUR) -55 °C Wind Specification — confirmed in the datasheet and quotation for your order.
Application fit
FDGG / FDGU 1.8/3 kV (0.6/1 kV) Ultra-Cold (-55 °C to +125 °C) Silicone / PUR Wind Turbine Torsion Cable (TICW/01 / GB/T 29631) engineered for 1.8/3 kV (0.6/1 kV) wind turbine service across -55 to +125 °C (min. bend radius 5 × OD).
Class 5 flexible copper cores and cross-linked EPR / silicone / PCP rubber jackets survive >10,000–18,000 yaw drip-loop torsion cycles.
Routes continuously from nacelle generators and yaw/pitch cabinets through the free-hanging drip loop into upper tower trays.
Polychloroprene (CR/PCP), CPE, silicone (FDGG) and PUR (FDGU) sheaths resist hydraulic oil, grease, ozone, salt spray and −40 to −55 °C co
Copper-braid screened variants (FDEFP, FDEHP, WINDLINK WTTC) contain PWM converter electromagnetic interference along the drip loop.
Wind turbine vertical torsion rubber cable is optimized for axial twist rather than high-speed trolley festoons.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: FDGG / FDGU 1.8/3 kV Ultra-Cold (TICW/01 & GB/T 29631 FDGG (Silicone/Silicone) & FDGU (Silicone/PUR) -55 °C Wind Specification) featuring class 5 tinned flexible copper conductors, high-tear silicone rubber insulation (code g) and silicone (fdgg) / ultra-cold pur (fdgu) jacket (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 Tinned Flexible Copper Conductor | Stranded tinned copper cores for single- and multi-core circuits |
| 2 | High-Tear Silicone Rubber Insulation (Co | Flexible down to -55 °C and heat-resistant up to +125 °C |
| 3 | Silicone (FDGG) / Ultra-Cold PUR (FDGU) | Extreme-arctic (-55 °C) torsion-resistant outer sheath |
Built to TICW/01 & GB/T 29631 FDGG (Silicone/Silicone) & FDGU (Silicone/PUR) -55 °C Wind Specification with class 5 tinned flexible copper conductors and silicone (fdgg) / ultra-cold pur (fdgu) jacket
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to TICW/01 & GB/T 29631 FDGG (Silicone/Silicone) & FDGU (Silicone/PUR) -55 °C Wind Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| FDGG / FDGU 1.8/3 kV Ultra-Cold Construction Schedule (−55…+125 °C) | |||||||
| FDGG 1×95 / 4G25 Cu | 1 × 95 mm² (or 4G25 mm² / 3/0 AWG) | IEC 60228 Class 5 Flexible Cu/SnCu | 21.6 | 1,080 | 14.2 | 110 | |
| FDGG 1×185 / 4G50 Cu | 1 × 185 mm² (or 4G50 mm² / 373 kcmil) | IEC 60228 Class 5 Flexible Cu/SnCu | 27.8 | 1,960 | 27.5 | 140 | |
| FDGG 1×300 / 4G95 Cu | 1 × 300 mm² (or 1×535/777 kcmil) | IEC 60228 Class 5 Flexible Cu/SnCu | 34.6 | 3,120 | 45.0 | 175 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 1 × 95 mm² (or 4G25 mm² / 3/0 AWG) | 0.21 | 1.8/3 kV (0.6/1 kV) (320 A Cu) | −55…+125 °C |
| 1 × 185 mm² (or 4G50 mm² / 373 kcmil) | 0.11 | 1.8/3 kV (0.6/1 kV) (495 A Cu) | −55…+125 °C |
| 1 × 300 mm² (or 1×535/777 kcmil) | 0.06 | 1.8/3 kV (0.6/1 kV) (680 A Cu) | −55…+125 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (TICW/01 & GB/T 29631 FDGG (Silicone/Silicone) & FDGU (Silicone/PUR) -55 °C Wind Specification) | DC resistance at 20 °C and insulation/sheath wall thickness within TICW/01 & GB/T 29631 FDGG (Silicone/Silicone) & FDGU (Silicone/PUR) -55 °C Wind Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (TICW/01 & GB/T 29631 FDGG (Silicone/Silicone) & FDGU (Silicone/PUR) -55 °C Wind Specification) | Zero dielectric breakdown and verified insulation resistance for 1.8/3 kV (0.6/1 kV) rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (TICW/01 & GB/T 29631 FDGG (Silicone/Silicone) & FDGU (Silicone/PUR) -55 °C Wind Specification) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −55…+125 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.