Immersion & wet locations
Engineered for deep-water hydrostatic immersion and marine deployment per IEC 60092-350 / ISO 13628-5 / MIL-C-17.
Product
DSM 40-01 40 Ω high-voltage subsea coaxial cable engineered for towed sonar arrays, acoustic transducers and oceanographic telemetry to 6,000 m depth, with tinned copper core, FEP dielectric and neoprene jacket.
Typical values for this cable type, based on IEC 60092-350 / ISO 13628-5 / MIL-C-17 — confirmed in the datasheet and quotation for your order.
Application fit
DSM 40-01 40 Ω high-voltage subsea coaxial cable engineered for towed sonar arrays, acoustic transducers and oceanographic telemetry to 6,000 m depth, with tinned copper core, FEP dielectric and neoprene jacket.
Engineered for deep-water hydrostatic immersion and marine deployment per IEC 60092-350 / ISO 13628-5 / MIL-C-17.
Suitable for subsea winch deployment, LARS sheaves and vertical marine suspension within 10–15 × OD.
Verified for fixed subsea structure routing, deck jumpers and seabed interconnections.
Not intended for high-cycle dry factory drag chains; select a dedicated拖链/drag-chain cable for indoor automation.
Subsea ROV Main Lift UmbilicalConstruction
Shown: DSM 40-01 (IEC 60092-350 / ISO 13628-5 / MIL-C-17) featuring stranded tinned copper center conductor, fep fluoropolymer dielectric core and neoprene (polychloroprene) outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Tinned Copper Center Conductor | Electrolytic tinned copper strands (7 x 0.40 mm / 0.88 mm²) for low-loss RF & sonar transmissionIEC 60092-350 / ISO 13628-5 / MIL-C-17 |
| 2 | FEP Fluoropolymer Dielectric Core | Extruded fluorinated ethylene propylene (FEP) solid dielectric core (OD 5.0 mm, 4.5 kV peak)IEC 60092-350 / ISO 13628-5 / MIL-C-17 |
| 3 | Tinned Copper Coaxial Braid Screen | High-coverage woven tinned copper wire coaxial return conductor and EMI screen (>= 90% optical coverage)IEC 60092-350 / ISO 13628-5 / MIL-C-17 |
| 4 | Rubberized Separator Tape | Helically lapped rubberized fabric binding tape stabilizing the coaxial braid under hydrostatic pressureIEC 60092-350 / ISO 13628-5 / MIL-C-17 |
| 5 | Neoprene (Polychloroprene) Outer Sheath | Heavy-duty black polychloroprene (CR / Neoprene) marine outer jacket resistant to seawater, oil, and abrasionIEC 60092-350 / ISO 13628-5 / MIL-C-17 |
Built to IEC 60092-350 / ISO 13628-5 / MIL-C-17 with stranded tinned copper center conductor and neoprene (polychloroprene) outer sheath
Available in continuous subsea winch lengths or factory-moulded / socket-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, optical & hydrostatic test report
Technical data
Sizes
Manufactured to IEC 60092-350 / ISO 13628-5 / MIL-C-17 for deep-water ROV, towed array, mooring and subsea production systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight in air ≈ kg/km | Breaking load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| DSM 40-01 Subsea Construction Schedule (−40…+80 °C) | |||||||
| DSM 40-01 Standard | 1 × 16.5 mm² (40 Ω) | 37 × 0.75 mm Cu | 15.9 | 430 | 12.5 | 160 | |
| DSM 40-01 Aramid-Reinforced | 1 × 16.5 mm² (40 Ω) | 37 × 0.75 mm Cu | 17.8 | 510 | 35.0 | 180 | |
| DSM 40-01 Double-Armoured | 1 × 16.5 mm² (40 Ω) | 37 × 0.75 mm Cu | 21.4 | 1,180 | 95.0 | 320 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 1 × 16.5 mm² (40 Ω) | 1.13 | 84 pF/m | −40…+80 °C |
| 1 × 16.5 mm² (40 Ω Aramid) | 1.13 | 84 pF/m | −40…+80 °C |
| 1 × 16.5 mm² (40 Ω Armoured) | 1.13 | 84 pF/m | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR & dimensional verification (IEC 60092-350 / ISO 13628-5 / MIL-C-17) | Electrical resistance, optical attenuation at 1310/1550 nm and OD within IEC 60092-350 / ISO 13628-5 / MIL-C-17 tolerances | Every manufactured drum / assembly |
| High-voltage dielectric & insulation resistance test (IEC 60092-350 / ISO 13628-5 / MIL-C-17) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / assembly |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & bend-over-sheave qualification (IEC 60092-350 / ISO 13628-5 / MIL-C-17) | Verified structural and transmission integrity under deep-water pressure and tensile cycling across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.