Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
DR-2 / DR-2 CD & V-String Double-Armored Subsea CP Monitoring Cable (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard) engineered for 300/500 V service across -30 °C to +80 °C (min. bend radius 10 × OD).
Typical values for this cable type, based on DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard — confirmed in the datasheet and quotation for your order.
Application fit
DR-2 / DR-2 CD & V-String Double-Armored Subsea CP Monitoring Cable (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard) engineered for 300/500 V service across -30 °C to +80 °C (min. bend radius 10 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: DR-2 / DR-2 CD & V-STRING (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard) featuring cp monitoring conductors (4×12 awg / 2×12 awg), epc insulation & copper/polyester shield and black hdpe jacket (or v-string polyester braid) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | CP Monitoring Conductors (4×12 AWG / 2×12 AWG) | Annealed copper 3.3 mm² cores for Ag/AgCl cell, Zn cell & 1 m² current-density shunt |
| 2 | EPC Insulation & Copper/Polyester Shield | Ethylene-propylene copolymer insulation + EPC fillers + drain wire + Cu/Polyester tape |
| 3 | Extruded TPU Inner Bedding Jacket | Tough thermoplastic polyurethane inner jacket protecting shielded core |
| 4 | Double Galvanized Steel Wire Armor (2×SWA) | Two contra-helical layers of galvanized steel armor for conduit-free jacket clamping |
| 5 | Black HDPE Jacket (or V-String Polyester Braid) | Black HDPE jacket (Ø 14/22 mm; V-String uses MIL-DTL-83420 steel cord + Polyester braid) |
Built to DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard with cp monitoring conductors (4×12 awg / 2×12 awg) and black hdpe jacket (or v-string polyester braid)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| DR-2 / DR-2 CD & V-STRING Construction Schedule (−30…+80 °C) | |||||||
| DR-2 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| DR-2 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| DR-2 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 300/500 V (45–100 Ω data) | −30…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 300/500 V (45–100 Ω data) | −30…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 300/500 V (High-Power Hybrid) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard) | Zero dielectric breakdown and verified insulation resistance for 300/500 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard) | Verified submersion integrity, tensile load and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.