Contact
25–30 year subsea cathodic protection reference & shunt cableDNV-RP-B401 / MIL-83420Ag/AgCl ±5 mV CP Reference25–30 Year Double SWA

DR-2 / DR-2 CD & V-String Double-Armored Subsea CP Monitoring CableDNV-RP-B401 / MIL-83420 · 300/500 V · 25–30 year subsea cathodic protection reference

DR-2 / DR-2 CD & V-String Double-Armored Subsea CP Monitoring Cable (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard) engineered for 300/500 V service across -30 °C to +80 °C (min. bend radius 10 × OD).

Water-resistant
Oil-resistant
Outdoor & humid
Approved
Order designation
DR-2 Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
Tested per DNV-RP-B401 / MIL-83420
Operating temp.
−30…+80 °C
Continuous subsea & marine service
Min. bend radius
10 × OD
Dynamic sheave & fixed routing
Core / conductor
2×12/4×12 AWG Cu
3.3 mm² Cu cores for Ag/AgCl & Zn
Outer protection
Double SWA
Contra-helical double SWA
Standard
DNV-RP-B401
DNV-RP-B401

Typical values for this cable type, based on DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is DR-2 / DR-2 CD & V-STRING right for your machine?

DR-2 / DR-2 CD & V-String Double-Armored Subsea CP Monitoring Cable (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard) engineered for 300/500 V service across -30 °C to +80 °C (min. bend radius 10 × OD).

Immersion & wet locations

Suitable

Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.

Vertical / spreader reel

Suitable

Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.

Offshore platform & shipboard deck trays

Suitable

Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.

Trailing & towing

Suitable

High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.

Energy chain / drag chain

Not suitable

Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableWork-Class & Observation ROV SystemsOffshore Wind & Subsea Power GridsOceanographic, Sonar & Seismic SurveyCommercial Diving & Subsea Intervention

Construction

Layer by layer

Shown: DR-2 / DR-2 CD & V-STRING (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard) featuring cp monitoring conductors (4×12 awg / 2×12 awg), epc insulation & copper/polyester shield and black hdpe jacket (or v-string polyester braid) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1CP Monitoring Conductors (4×12 AWG / 2×12 AWG)Annealed copper 3.3 mm² cores for Ag/AgCl cell, Zn cell & 1 m² current-density shunt
2EPC Insulation & Copper/Polyester ShieldEthylene-propylene copolymer insulation + EPC fillers + drain wire + Cu/Polyester tape
3Extruded TPU Inner Bedding JacketTough thermoplastic polyurethane inner jacket protecting shielded core
4Double Galvanized Steel Wire Armor (2×SWA)Two contra-helical layers of galvanized steel armor for conduit-free jacket clamping
5Black HDPE Jacket (or V-String Polyester Braid)Black HDPE jacket (Ø 14/22 mm; V-String uses MIL-DTL-83420 steel cord + Polyester braid)

DR-2 / DR-2 CD & V-STRING — Standard Subsea & Marine Execution

Built to DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard with cp monitoring conductors (4×12 awg / 2×12 awg) and black hdpe jacket (or v-string polyester braid)

DR-2 / DR-2 CD & V-STRING — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

DR-2 / DR-2 CD & V-STRING — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
300/500 V (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard)
Core / conductor construction
CP Monitoring Conductors (4×12 AWG / 2×12 AWG) — Annealed copper 3.3 mm² cores for Ag/AgCl cell, Zn cell & 1 m² current-density shunt
Primary dielectric / buffering
EPC Insulation & Copper/Polyester Shield — Ethylene-propylene copolymer insulation + EPC fillers + drain wire + Cu/Polyester tape

Thermal

Continuous operating temperature
−30…+80 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Black HDPE Jacket (or V-String Polyester Braid) — Black HDPE jacket (Ø 14/22 mm; V-String uses MIL-DTL-83420 steel cord + Polyester braid)
Minimum bending radius
10 × OD
Hydrostatic, tensile & crush duty
Double Galvanized Steel Wire Armor (2×SWA) — Two contra-helical layers of galvanized steel armor for conduit-free jacket clamping

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
DR-2 / DR-2 CD & V-STRING
Sheath colour & metre marking
Continuous metre-marked black outer finish (Double SWA + Black HDPE)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard DR-2 / DR-2 CD & V-STRING subsea & marine configurations

Manufactured to DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
DR-2 / DR-2 CD & V-STRING Construction Schedule (−30…+80 °C)
DR-2 Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
DR-2 Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
DR-2 Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard)DC resistance at 20 °C / optical attenuation and outer diameter within DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard)Zero dielectric breakdown and verified insulation resistance for 300/500 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard)Verified submersion integrity, tensile load and thermal stability across −30…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DNV-RP-B401 / MIL-83420 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX DR-2 / DR-2 CD & V-STRING DNV-RP-B401 / MIL-83420 300/500 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define DR-2 / DR-2 CD & V-STRING (DR-2 / DR-2 CD & V-String Double-Armored Subsea CP Monitoring Cable)?
DR-2 / DR-2 CD & V-STRING (DR-2 / DR-2 CD & V-String Double-Armored Subsea CP Monitoring Cable) is manufactured in accordance with DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard for 300/500 V service over -30 °C to +80 °C. Its 5-layer construction comprises cp monitoring conductors (4×12 awg / 2×12 awg), epc insulation & copper/polyester shield and black hdpe jacket (or v-string polyester braid).
What is the minimum bending radius and operating temperature range for DR-2 / DR-2 CD & V-STRING?
The minimum bending radius for DR-2 / DR-2 CD & V-STRING is 10 × OD across its continuous operating temperature range of -30 °C to +80 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of DR-2 / DR-2 CD & V-STRING arranged from inside to outside?
From inside to outside, the construction sequence is: (01) CP Monitoring Conductors (4×12 AWG / 2×12 AWG) — Annealed copper 3.3 mm² cores for Ag/AgCl cell, Zn cell & 1 m² current-density shunt; (02) EPC Insulation & Copper/Polyester Shield — Ethylene-propylene copolymer insulation + EPC fillers + drain wire + Cu/Polyester tape; (03) Extruded TPU Inner Bedding Jacket — Tough thermoplastic polyurethane inner jacket protecting shielded core; (04) Double Galvanized Steel Wire Armor (2×SWA) — Two contra-helical layers of galvanized steel armor for conduit-free jacket clamping; (05) Black HDPE Jacket (or V-String Polyester Braid) — Black HDPE jacket (Ø 14/22 mm; V-String uses MIL-DTL-83420 steel cord + Polyester braid).
What factory test certificates are supplied with DR-2 / DR-2 CD & V-STRING?
Every production drum of DR-2 / DR-2 CD & V-STRING undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per DNV-RP-B401 / MIL-DTL-83420 Subsea CP Monitoring Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for DR-2 / DR-2 CD & V-STRING

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

DR-2 / DR-2 CD & V-String Double-Armored Subsea CP Monitoring Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote