Free-hanging vertical run
19-strand / finely stranded copper pairs and stabilizing inner bedding maintain constant 150 Ω / 120 Ω impedance during ±150°/m yaw torsion.
Product
120-Ohm CAN BUS 2×2×0.25 mm² (300 V) Foam-Skin PE + 85% TCWB Shielded Halogen-Free PUR Wind Turbine Data Cable (ISO 11898-2 / CiA 303-1) engineered for 300 V wind turbine service across -40 to +80 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification — confirmed in the datasheet and quotation for your order.
Application fit
120-Ohm CAN BUS 2×2×0.25 mm² (300 V) Foam-Skin PE + 85% TCWB Shielded Halogen-Free PUR Wind Turbine Data Cable (ISO 11898-2 / CiA 303-1) engineered for 300 V wind turbine service across -40 to +80 °C (min. bend radius 6 × OD).
19-strand / finely stranded copper pairs and stabilizing inner bedding maintain constant 150 Ω / 120 Ω impedance during ±150°/m yaw torsion.
Halogen-free oil- and hydrolysis-resistant PUR outer sheath withstands dynamic flexing inside rotor hubs, slip-rings and nacelle loops.
100% Al/PET foil plus high-density tinned copper wire braid (85%) shields fieldbus telegrams against high-power IGBT converter noise.
Standard colour-coded PROFIBUS (Red/Green) and CANopen (White/Brown, Green/Yellow) pairs fit industrial M12 and D-Sub bus connectors.
Nacelle and tower PUR fieldbus cable is not designed for deep-ocean hydrostatic immersion.
Use Subsea Ethernet CableConstruction
Shown: CAN BUS 2×2×0.25 mm² PUR 300 V (ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification) featuring stranded copper twisted pairs (2×2x0.25 mm²), 120-ohm foam-skin pe dielectric and halogen-free oil-resistant pur jacket (-40 °c) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Copper Twisted Pairs (2×2x0.25 | Finely stranded plain copper pairs coded White/Brown & Green/Yellow |
| 2 | 120-Ohm Foam-Skin PE Dielectric | Low-loss cellular foam-skin polyethylene for CANopen signal integrity |
| 3 | 85% Tinned Copper Wire Braid Shield | High-coverage tinned copper braid shielding against converter EMI |
| 4 | Halogen-Free Oil-Resistant PUR Jacket (- | Flame-retardant polyurethane outer sheath (-40 °C to +80 °C) |
Built to ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification with stranded copper twisted pairs (2×2x0.25 mm²) and halogen-free oil-resistant pur jacket (-40 °c)
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| CAN BUS 2×2×0.25 mm² PUR 300 V Construction Schedule (−40…+80 °C) | |||||||
| CAN BUS 2×2×0.25 mm² PUR 300 V 1×2×0.34 mm² | 1 × 2 × 0.34 mm² (22 AWG) Bus Pair | 19-strand Cu + Foam PE + Foil/TCWB | 8.0 | 88 | 0.9 | 50 | |
| CAN BUS 2×2×0.25 mm² PUR 300 V 2×2×0.25 mm² | 2 × 2 × 0.25 mm² (24 AWG) CANopen | Finely stranded Cu + Foam-Skin PE + TCWB | 8.6 | 104 | 1.1 | 55 | |
| CAN BUS 2×2×0.25 mm² PUR 300 V 2×2×0.34 mm² | 2 × 2 × 0.34 mm² Redundant Bus | 19-strand Cu + Foam PE + Dual Shield | 10.4 | 148 | 1.5 | 65 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 1 × 2 × 0.34 mm² (22 AWG) Bus Pair | 55.00 | 300 V (120/150 Ω) | −40…+80 °C |
| 2 × 2 × 0.25 mm² (24 AWG) CANopen | 78.00 | 300 V (120 Ω CAN) | −40…+80 °C |
| 2 × 2 × 0.34 mm² Redundant Bus | 55.00 | 300 V (120/150 Ω) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification) | DC resistance at 20 °C and insulation/sheath wall thickness within ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification) | Zero dielectric breakdown and verified insulation resistance for 300 V rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.