120-Ohm CAN BUS 2×2×0.25 mm² (300 V) Foam-Skin PE + 85% TCWB Shielded Halogen-Free PUR Wind Turbine Data CableISO 11898-2 / CiA 303-1 — 300 V — -40 to +80 °C Wind Turbine Cable

120-Ohm CAN BUS 2×2×0.25 mm² (300 V) Foam-Skin PE + 85% TCWB Shielded Halogen-Free PUR Wind Turbine Data Cable (ISO 11898-2 / CiA 303-1) engineered for 300 V wind turbine service across -40 to +80 °C (min. bend radius 6 × OD).

Anti-torsion braid
EMC screen
Oil-resistant
Approved
Order designation
CAN BUS 2×2×0.25 mm² PUR 300 V 1×2×0.34 mm²
Outer Ø ≈
8.0 mm
Net weight ≈
88 kg/km
Max. pulling ≈
0.9 kN
Core / stranding
19-strand Cu + Foam PE + Foil/TCWB
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V
Tested per ISO 11898-2 / CiA 303-1
Operating temp.
−40…+80 °C
Cold-climate & nacelle wind service
Min. bend radius
6 × OD
Drip-loop, hub & tower routing
Core / conductor
Stranded Copper
Finely stranded plain copper pairs coded
Outer protection
Halogen-Free Oil
Flame-retardant polyurethane outer sheat
Standard
ISO 11898-2 / Ci
ISO 11898-2 & CiA 303-1 120-Ohm CANopen

Typical values for this cable type, based on ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is CAN BUS 2×2×0.25 mm² PUR 300 V right for your machine?

120-Ohm CAN BUS 2×2×0.25 mm² (300 V) Foam-Skin PE + 85% TCWB Shielded Halogen-Free PUR Wind Turbine Data Cable (ISO 11898-2 / CiA 303-1) engineered for 300 V wind turbine service across -40 to +80 °C (min. bend radius 6 × OD).

Free-hanging vertical run

Suitable

19-strand / finely stranded copper pairs and stabilizing inner bedding maintain constant 150 Ω / 120 Ω impedance during ±150°/m yaw torsion.

Energy chain / drag chain

Suitable

Halogen-free oil- and hydrolysis-resistant PUR outer sheath withstands dynamic flexing inside rotor hubs, slip-rings and nacelle loops.

Fixed installation

Suitable

100% Al/PET foil plus high-density tinned copper wire braid (85%) shields fieldbus telegrams against high-power IGBT converter noise.

Switchgear & control cabinet wiring

Suitable

Standard colour-coded PROFIBUS (Red/Green) and CANopen (White/Brown, Green/Yellow) pairs fit industrial M12 and D-Sub bus connectors.

Immersion & wet locations

Not suitable

Nacelle and tower PUR fieldbus cable is not designed for deep-ocean hydrostatic immersion.

Use Subsea Ethernet Cable
Typical machinesRenewable Energy & EV ChargingWind Turbine Main PLC, Yaw & Pitch Fieldbus NetworksPROFIBUS DP & CANopen Hub-to-Nacelle Slip-Ring LinksAnemometer, Vibration, Ice & Condition Monitoring SensorsCold-Climate (−40 °C) Wind Farm SCADA & Telemetry

Construction

Layer by layer

Shown: CAN BUS 2×2×0.25 mm² PUR 300 V (ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification) featuring stranded copper twisted pairs (2×2x0.25 mm²), 120-ohm foam-skin pe dielectric and halogen-free oil-resistant pur jacket (-40 °c) (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded Copper Twisted Pairs (2×2x0.25 Finely stranded plain copper pairs coded White/Brown & Green/Yellow
2120-Ohm Foam-Skin PE DielectricLow-loss cellular foam-skin polyethylene for CANopen signal integrity
385% Tinned Copper Wire Braid ShieldHigh-coverage tinned copper braid shielding against converter EMI
4Halogen-Free Oil-Resistant PUR Jacket (-Flame-retardant polyurethane outer sheath (-40 °C to +80 °C)

CAN BUS 2×2×0.25 mm² PUR 300 V — Standard Wind Turbine Execution

Built to ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification with stranded copper twisted pairs (2×2x0.25 mm²) and halogen-free oil-resistant pur jacket (-40 °c)

CAN BUS 2×2×0.25 mm² PUR 300 V — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

CAN BUS 2×2×0.25 mm² PUR 300 V — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
300 V (ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification)
Core / conductor construction
Stranded Copper Twisted Pairs (2×2x0.25 mm²) — Finely stranded plain copper pairs coded White/Brown & Green/Yellow
Primary dielectric / insulation
120-Ohm Foam-Skin PE Dielectric — Low-loss cellular foam-skin polyethylene for CANopen signal integrity

Thermal

Continuous operating temperature
−40…+80 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −40…+80 °C per ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Halogen-Free Oil-Resistant PUR Jacket (-40 °C) — Flame-retardant polyurethane outer sheath (-40 °C to +80 °C)
Minimum bending radius
6 × OD
Intermediate screen / separator / core layer
85% Tinned Copper Wire Braid Shield — High-coverage tinned copper braid shielding against converter EMI

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
CAN BUS 2×2×0.25 mm² PUR 300 V
Sheath colour & metre marking
Continuous metre-marked black outer finish (Halogen-Free Oil)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard CAN BUS 2×2×0.25 mm² PUR 300 V wind turbine configurations

Manufactured to ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
CAN BUS 2×2×0.25 mm² PUR 300 V Construction Schedule (−40…+80 °C)
CAN BUS 2×2×0.25 mm² PUR 300 V 1×2×0.34 mm²1 × 2 × 0.34 mm² (22 AWG) Bus Pair19-strand Cu + Foam PE + Foil/TCWB8.0880.950
CAN BUS 2×2×0.25 mm² PUR 300 V 2×2×0.25 mm²2 × 2 × 0.25 mm² (24 AWG) CANopenFinely stranded Cu + Foam-Skin PE + TCWB8.61041.155
CAN BUS 2×2×0.25 mm² PUR 300 V 2×2×0.34 mm²2 × 2 × 0.34 mm² Redundant Bus19-strand Cu + Foam PE + Dual Shield10.41481.565
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification)DC resistance at 20 °C and insulation/sheath wall thickness within ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification)Zero dielectric breakdown and verified insulation resistance for 300 V ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ISO 11898-2 / CiA 303-1 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX CAN BUS 2×2×0.25 mm² PUR 300 V ISO 11898-2 / CiA 303-1 300 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define CAN BUS 2×2×0.25 mm² PUR 300 V (120-Ohm CAN BUS 2×2×0.25 mm² (300 V) Foam-Skin PE + 85% TCWB Shielded Halogen-Free PUR Wind Turbine Data Cable)?
CAN BUS 2×2×0.25 mm² PUR 300 V (120-Ohm CAN BUS 2×2×0.25 mm² (300 V) Foam-Skin PE + 85% TCWB Shielded Halogen-Free PUR Wind Turbine Data Cable) is manufactured in accordance with ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification for 300 V wind turbine service over -40 to +80 °C. Its 4-layer construction comprises stranded copper twisted pairs (2×2x0.25 mm²), 120-ohm foam-skin pe dielectric and halogen-free oil-resistant pur jacket (-40 °c).
What is the minimum bending radius and operating temperature range for CAN BUS 2×2×0.25 mm² PUR 300 V?
The minimum bending radius for CAN BUS 2×2×0.25 mm² PUR 300 V is 6 × OD across its continuous operating temperature range of -40 to +80 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of CAN BUS 2×2×0.25 mm² PUR 300 V arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded Copper Twisted Pairs (2×2x0.25 mm²) — Finely stranded plain copper pairs coded White/Brown & Green/Yellow; (02) 120-Ohm Foam-Skin PE Dielectric — Low-loss cellular foam-skin polyethylene for CANopen signal integrity; (03) 85% Tinned Copper Wire Braid Shield — High-coverage tinned copper braid shielding against converter EMI; (04) Halogen-Free Oil-Resistant PUR Jacket (-40 °C) — Flame-retardant polyurethane outer sheath (-40 °C to +80 °C).
What factory test certificates are supplied with CAN BUS 2×2×0.25 mm² PUR 300 V?
Every production drum of CAN BUS 2×2×0.25 mm² PUR 300 V undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per ISO 11898-2 & CiA 303-1 120-Ohm CANopen 2×2×0.25 mm² PUR Wind Turbine Data Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for CAN BUS 2×2×0.25 mm² PUR 300 V

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

CAN BUS 2×2×0.25 mm² PUR 300 V 120-Ohm CAN BUS 2×2×0.25 mm² (300 V) Foam-Skin PE + 85% TCWB Shielded Halogen-Free PUR Wind Turbine Data Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote