instrumentation cable seriesBS 6883 / UKOOA150/250 V & 0.6/1 kVGSWB / PBWB Armoured

BS 6883 AIS / ACS Armoured Offshore Instrumentation CableUKOOA Type 4 EPR-insulated wire-braid armoured offshore instrumentation cable

BS 6883 AIS (Armoured Individually Screened) and ACS (Armoured Collectively Screened) 150/250 V & 600/1000 V offshore instrumentation cable with Class 2/5 tinned copper cores, GP4 EPR insulation, galvanized steel or phosphor-bronze.

IEC 60332-3-22 Cat A
SW4 Oil & Mud Resistant
AIS / ACS Foil Screen
BS 6883 UKOOA
Order designation
BS 6883 AIS 5P×1.0
Outer Ø ≈
19.4 mm
Weight ≈
590 kg/km
Conductor DC R
18.2 Ω/km
Min. bend radius
116 mm
All sizes (8)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Standard
BS 6883:1999
UKOOA Type 4 offshore spec
Voltage rating
150/250 V
600/1000 V option available
Conductor
0.75 to 2.5 mm²
Tinned copper IEC 60228 Cl. 2/5
Insulation
EPR GP4 /GP5
BS 7655-1.2 elastomeric
Armour & sheath
GSWB + SW4 LSZH
Galvanized steel braid + SW4
Temperature
-40 to +90 °C
+250 °C short-circuit rating

Typical values for this cable type, based on BS 6883 / UKOOA / IEC 60092-376 — confirmed in the datasheet and quotation for your order.

Application fit

Is BS 6883 AIS / ACS right for your machine?

Engineered for fixed topside modules, FPSO process decks, drilling derricks and accommodation modules in the North Sea and global offshore oil & gas sectors.

Offshore platform & shipboard deck trays

Suitable

SW4 low-smoke zero-halogen elastomer sheath withstands salt spray, fuel oil, and ester drilling mud.

Fixed installation

Suitable

Clipped to topside stainless cable ladders, hazardous-area Ex d/Ex i junction boxes and DCS cabinets.

Switchgear & control cabinet wiring

Suitable

AIS individual + overall tape screens eliminate 4–20 mA, HART and Foundation Fieldbus crosstalk.

Energy chain / drag chain

Not suitable

Fixed offshore installation cable; for drag-chain skid loops specify dynamic offshore drag-chain cable.

Use PUR-HF Drag-Chain Cable
Typical machinesOffshore Fixed Platforms & TopsidesFPSO, FSO & FLNG VesselsJack-Up & Semi-Submersible RigsSubsea Umbilical Termination SkidsPetrochemical & LNG Marine Terminals

Construction

Layer by layer

BS 6883 AIS / ACS offshore cable showing tinned copper conductors, GP4 EPR insulation, twisted pairs/triads with Al/PET tape + tinned drain wire, SW4 inner bedding, galvanized steel wire braid (GSWB) armour, and SW4 LSZH outer sheath.

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Tinned annealed copper conductorsClass 2 (7-wire stranded) or Class 5 (flexible) tinned copper per BS EN 60228 (0.75, 1.0, 1.5, 2.5 mm²)Corrosion-resistant marine stranding
2GP4 / GP5 EPR thermoset insulationEthylene Propylene Rubber (EPR Type GP4 or hard-grade GP5 per BS 7655-1.2), pairs/triads numbered Black/White/(Red)90 °C continuous service
3Collective (ACS) or Individual + Collective (AIS) screenAluminium/polyester laminate tape in contact with a 0.50 mm² tinned copper drain wire100 % electrostatic coverage for Ex i & 4–20 mA loops
4SW4 bedding + Galvanized Steel Wire Braid (GSWB)Extruded SW4 halogen-free bedding + galvanized steel wire braid (or phosphor-bronze braid on single-core)≥ 90 % coverage mechanical & rodent/impact armour
5SW4 Heavy-Duty LSZH Offshore Outer SheathCross-linked halogen-free flame-retardant elastomer Type SW4 per BS 7655-2.6 (Grey non-Ex i or Blue Ex i)Low smoke, HCl < 0.5 %, oil & mud resistant

BS 6883 ACS (Collectively Screened)

Multipair/multitriad with overall Al/PET foil + GSWB armour + Grey/Blue SW4 sheath (UKOOA codes)

BS 6883 AIS (Individually & Collectively Screened)

Individual Al/PET screen on each pair/triad + overall screen + GSWB armour + SW4 sheath

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on BS 6883 / UKOOA / IEC 60092-376. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage (Uo/U)
150/250 V (instrumentation) · 600/1000 V (control/power)
Max. DC resistance @ 20 °C
24.8 Ω/km (0.75) · 18.2 Ω/km (1.0) · 12.2 Ω/km (1.5) · 7.56 Ω/km (2.5)
Mutual capacitance
≤ 115 pF/m (ACS) · ≤ 145 pF/m (AIS)
L/R ratio (inductance/resistance)
≤ 25 µH/Ω (0.75–1.0 mm²) · ≤ 40 µH/Ω (1.5 mm²)

Thermal

Operating temperature
-40 °C to +90 °C (fixed installation)
Short-circuit temperature
+250 °C (max. 5 s)
Minimum installation temp.
-20 °C

Mechanical

Min. bend radius
6 × OD (up to 25 mm OD) · 8 × OD (> 25 mm OD)
Braid wire tensile strength
1,250–1,400 N/mm² galvanized steel wire
Crush & impact resistance
Heavy-duty UKOOA Type 4 wire braid armour

Resistance

Bunched flame propagation
BS EN 60332-3-22 Category A
Halogen acid gas & smoke
BS EN 60754-1 (< 0.5 % HCl) & BS EN 61034-2 (≥ 60 %)
Oil & fluid immersion
BS 7655-2.6 Type SW4 IRM 902/903 oil & fuel resistant

Reference standards

Primary design standard
BS 6883 & UKOOA Cable Code
Material specifications
BS 7655-1.2 (GP4 EPR) & BS 7655-2.6 (SW4)
RoHS & REACH
2011/65/EU & EC 1907/2006 compliant

Identification

Core identification
Pairs: Black & White numbered · Triads: Black, White & Red
Outer sheath colour
Grey (standard) or Light Blue (Ex i intrinsically safe)
Customs tariff (HS)
8544.4993

Sizes

8 standard BS 6883 ACS & AIS 150/250 V offshore configurations

Nominal dimensions, UKOOA reference codes and weights for BS 6883 wire-braid armoured offshore cables.

Dimensions & UKOOA weights
Order designationUKOOA code & pairsOuter Ø ≈
mm
Weight ≈
kg/km
Max. DC R
Ω/km
Min. bend R
mm
Enquiry
BS 6883 ACS — Collectively Screened + GSWB
BS 6883 ACS 1P×0.75YJJ01 · 1 Pair 0.75 mm²10.417524.862
BS 6883 ACS 2P×0.75YJJ02 · 2 Pair 0.75 mm²13.527024.881
BS 6883 ACS 5P×1.0YJK05 · 5 Pair 1.0 mm²18.252018.2109
BS 6883 ACS 10P×1.5YJL10 · 10 Pair 1.5 mm²24.898012.2149
BS 6883 AIS — Individually & Collectively Screened + GSWB
BS 6883 AIS 2P×0.75YJP02 · 2 Pair 0.75 mm²14.230524.885
BS 6883 AIS 5P×1.0YJQ05 · 5 Pair 1.0 mm²19.459018.2116
BS 6883 AIS 10P×1.0YJQ10 · 10 Pair 1.0 mm²24.694018.2148
BS 6883 AIS 20P×1.5YJR20 · 20 Pair 1.5 mm²33.81,84012.2270
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Also available in 1, 3, 7 and 12 triad formations and 600/1000 V rated thickness.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
1.5 kV / 3.5 kV AC spark & dielectric voltage test5 min AC withstand without breakdown (1.5 kV on 150/250 V; 3.5 kV on 0.6/1 kV)Every drum length
Sample tests
IEC 60332-3-22 Cat A bunched vertical flame testChar height ≤ 2.5 m under 40 min 7 L/m non-metallic volume burnType approval
BS 7655-2.6 SW4 oil immersion & HCl emission test< 0.5 % HCl gas emission and mechanical retention after hot oil bathType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

BS 6883 & UKOOA CompliantIEC 60332-3-22 Cat A & IEC 60754RoHS 2 & REACH Compliant

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX BS 6883 UKOOA 150/250V AIS/ACS GSWB SW4 LSZH
Delivery form
Fumigated wooden drums, steel reels or precision spools
Standard lengths
500 m · 1000 m (or custom cut/spooled lengths)
MOQ
100 m (standard) · 500 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-20
Updated
2026-10-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

When should an offshore engineer specify BS 6883 versus BS 7917?
Specify BS 6883 for general flame-retardant (IEC 60332-3-22 Cat A) instrumentation, process telemetry and PLC circuits. Specify BS 7917 (with phlogopite mica-glass fire barrier tape over each conductor) for emergency shutdown (ESD), fire & gas detection, blow-out preventer (BOP) controls, and deluge systems that must continue operating during an active +750/+950 °C hydrocarbon fire.
What is the difference between ACS and AIS screening in BS 6883?
ACS (Armoured Collectively Screened) places a single overall aluminium/PET foil tape + tinned drain wire around the assembled bundle of pairs/triads. AIS (Armoured Individually Screened) adds an isolated foil screen and drain wire around each individual pair or triad in addition to the collective screen, preventing inter-pair crosstalk between analogue 4–20 mA loops and high-frequency pulse/HART signals.
Why does BS 6883 use Type SW4 outer sheathing?
BS 7655-2.6 Type SW4 is a heavy-duty thermoset elastomeric compound combining zero-halogen low-smoke fire performance (< 0.5 % HCl) with high tear resistance and immersion resistance to mineral oils, diesel fuel and synthetic drilling fluids.
Which cable glands fit BS 6883 GSWB armoured cables?
BS 6883 cables terminate with standard Ex d / Ex e marine & offshore barrier or compression glands designed for wire-braid armour (such as CMP Type E1FW/PX2K or Hawke 501/453/UNIV).

Request a quote

Get an engineering quote for BS 6883 AIS / ACS

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

BS 6883 AIS / ACS Armoured Offshore Instrumentation Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote