90592RGYBEM 2×1.5 mm² Standard
Outer Ø ≈
8.4 mm
Net weight ≈
92 kg/km
Tensile rating ≈
0.5 kN
Core / stranding
7/0.50 mm plain Cu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
300/500 V detonator firing circuit
Operating temp.
-15 to +105 °C
Continuous mining & industrial duty
Min. bend radius
8 × OD
Fixed installation / dynamic routing
Core / conductor
2 × 1.5 mm² Cu
7/0.50 mm plain annealed copper
Outer protection
V90HT Striped
Yellow V90HT PVC with blue stripes
Standard
AS/NZS 3808
AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079

Typical values for this cable type, based on AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079 — confirmed in the datasheet and quotation for your order.

Application fit

Is 90592RGYBEM right for your machine?

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079 across -15 to +105 °C.

Mine roadway & tunnel wall hangers

Suitable

Engineered for underground mining shafts, galleries and tunnel infrastructure per AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079.

Fixed installation

Suitable

Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 8 × OD.

Free-hanging vertical run

Suitable

Supports inclined roadway and vertical mine shaft suspension within rated kN load across -15 to +105 °C.

Typical machinesMining & TunnellingUnderground Coal & Hard-Rock MiningOpen-Cast Excavators, Draglines & ShovelsVertical Mine Shafts, Hoists & BoreholesTunneling, Mineral Processing & Slurry Plants

Construction

Layer by layer

Shown: 90592RGYBEM (AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079) featuring stranded conductors (2×1.5 mm²), v90ht pvc core insulation and yellow/blue-striped outer sheath (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded Conductors (2×1.5 mm²)7/0.50 mm plain annealed copper conductors per AS/NZS 1125 (≤13.6 Ω/km)
2V90HT PVC Core Insulation0.7 mm wall Red & Green V90HT PVC primary insulation per AS/NZS 3808
3Yellow/Blue-Striped Outer Sheath1.3 mm heavy-duty yellow V90HT PVC sheath with co-extruded blue stripes

90592RGYBEM — Standard Mining Execution

Built to AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079 with stranded conductors (2×1.5 mm²) and yellow/blue-striped outer sheath

90592RGYBEM — Custom Drum Length & Gland Kit

Available in custom shaft/roadway drum lengths or pre-terminated assemblies

90592RGYBEM — Routine & Flame Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
300/500 V (AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079)
Core / conductor construction
Stranded Conductors (2×1.5 mm²) — 7/0.50 mm plain annealed copper conductors per AS/NZS 1125 (≤13.6 Ω/km)
Primary dielectric / buffering
V90HT PVC Core Insulation — 0.7 mm wall Red & Green V90HT PVC primary insulation per AS/NZS 3808

Thermal

Continuous operating temperature
-15 to +105 °C (mining & industrial service)
Short-circuit / peak thermal rating
Verified thermal stability per AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Yellow/Blue-Striped Outer Sheath — 1.3 mm heavy-duty yellow V90HT PVC sheath with co-extruded blue stripes
Minimum bending radius
8 × OD
Crush, impact & abrasion duty
Heavy-duty mining rock-cut, impact and tensile protection per AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079

Resistance

Flame retardancy & mine fire safety
Self-extinguishing / flame-retardant mining jacket per AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079
Mine water, oil & chemical resistance
Resistant to acidic mine water, hydraulic oils and abrasion per AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079
Flame & environmental test standards
IEC 60332 / MSHA / EN 60794 / IEC 60228
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
90592RGYBEM
Sheath colour & metre marking
Continuous metre-marked yellow mining outer sheath
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard 90592RGYBEM mining & industrial configurations

Manufactured to AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079 for underground mining, open-cast excavation, shaft and heavy industrial systems.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
90592RGYBEM Construction Schedule (-15 to +105 °C)
90592RGYBEM 2×1.5 mm² Standard2 × 1.5 mm² (7/0.50)7/0.50 mm plain Cu8.4920.568
90592RGYBEM 2×2.5 mm² Heavy Trunk2 × 2.5 mm² (7/0.67)7/0.67 mm plain Cu9.81350.878
90592RGYBEM 2×4.0 mm² Main Firing Bus2 × 4.0 mm² (7/0.85)7/0.85 mm plain Cu11.41951.292
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079)DC resistance at 20 °C / optical attenuation and outer diameter within AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079)Zero dielectric breakdown and verified insulation resistance over full production lengthEvery manufactured drum length
Sample tests
Flame propagation, mechanical crush & thermal ageing qualification (AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079)Verified flame retardancy, mechanical integrity and thermal endurance across -15 to +105 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

AS/NZS 3808 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 90592RGYBEM AS/NZS 3808 300/500 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel mine reels
Standard lengths
500 m, 1,000 m or custom continuous shaft/reeling lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-24
Updated
2026-10-24

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define 90592RGYBEM (90592RGYBEM AS/NZS 3808 Mining Shotfiring Cable)?
90592RGYBEM (90592RGYBEM AS/NZS 3808 Mining Shotfiring Cable) is manufactured in accordance with AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079 for 300/500 V duty over -15 to +105 °C. Its 3-layer construction comprises Stranded Conductors (2×1.5 mm²), V90HT PVC Core Insulation and Yellow/Blue-Striped Outer Sheath.
What is the minimum bending radius and operating temperature range for 90592RGYBEM?
The minimum bending radius for 90592RGYBEM is 8 × OD across its continuous operating temperature range of -15 to +105 °C, ensuring mechanical and dielectric reliability in mining and heavy industrial service.
How are the concentric layers of 90592RGYBEM arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded Conductors (2×1.5 mm²) (7/0.50 mm plain annealed copper conductors per AS/NZS 1125 (≤13.6 Ω/km)); (02) V90HT PVC Core Insulation (0.7 mm wall Red & Green V90HT PVC primary insulation per AS/NZS 3808); (03) Yellow/Blue-Striped Outer Sheath (1.3 mm heavy-duty yellow V90HT PVC sheath with co-extruded blue stripes).
What factory test certificates are supplied with 90592RGYBEM?
Every production drum of 90592RGYBEM undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for 90592RGYBEM

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

90592RGYBEM AS/NZS 3808 Mining Shotfiring Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote