Mine roadway & tunnel wall hangers
Engineered for underground mining shafts, galleries and tunnel infrastructure per AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079 across -15 to +105 °C.
Typical values for this cable type, based on AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079 across -15 to +105 °C.
Engineered for underground mining shafts, galleries and tunnel infrastructure per AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079.
Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 8 × OD.
Supports inclined roadway and vertical mine shaft suspension within rated kN load across -15 to +105 °C.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: 90592RGYBEM (AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079) featuring stranded conductors (2×1.5 mm²), v90ht pvc core insulation and yellow/blue-striped outer sheath (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Conductors (2×1.5 mm²) | 7/0.50 mm plain annealed copper conductors per AS/NZS 1125 (≤13.6 Ω/km) |
| 2 | V90HT PVC Core Insulation | 0.7 mm wall Red & Green V90HT PVC primary insulation per AS/NZS 3808 |
| 3 | Yellow/Blue-Striped Outer Sheath | 1.3 mm heavy-duty yellow V90HT PVC sheath with co-extruded blue stripes |
Built to AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079 with stranded conductors (2×1.5 mm²) and yellow/blue-striped outer sheath
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 90592RGYBEM Construction Schedule (-15 to +105 °C) | |||||||
| 90592RGYBEM 2×1.5 mm² Standard | 2 × 1.5 mm² (7/0.50) | 7/0.50 mm plain Cu | 8.4 | 92 | 0.5 | 68 | |
| 90592RGYBEM 2×2.5 mm² Heavy Trunk | 2 × 2.5 mm² (7/0.67) | 7/0.67 mm plain Cu | 9.8 | 135 | 0.8 | 78 | |
| 90592RGYBEM 2×4.0 mm² Main Firing Bus | 2 × 4.0 mm² (7/0.85) | 7/0.85 mm plain Cu | 11.4 | 195 | 1.2 | 92 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 1.5 mm² (7/0.50) | 13.60 | 27.2 Ω/km loop resistance | -15 to +105 °C |
| 2 × 2.5 mm² (7/0.67) | 7.41 | 14.8 Ω/km loop resistance | -15 to +105 °C |
| 2 × 4.0 mm² (7/0.85) | 4.61 | 9.22 Ω/km loop resistance | -15 to +105 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079) | DC resistance at 20 °C / optical attenuation and outer diameter within AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (AS/NZS 3808 / AS/NZS 1125 / AS/NZS 60079) | Verified flame retardancy, mechanical integrity and thermal endurance across -15 to +105 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.