A-2YF2Y StIIIBd Jelly-Filled Laminated-Sheath Outdoor Telecom CableDIN VDE 0816-1 · 225 V peak · -40 °C to +70 °C industrial A-2YF(L)2Y StIIIBd construction

A-2YF2Y StIIIBd Jelly-Filled Laminated-Sheath Outdoor Telecom Cable2Y StIIIBd) engineered to DIN VDE 0816-1 for 225 V peak service across -40 °C to +70 °C, featuring stranded copper conductor and black pe outer sheath with minimum bending radius 10 × OD.

Approved
Low-EMC design
EMC screen
Outdoor & humid
Order designation
A-2YF(L)2Y StIIIBd 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
225 V peak
Per DIN VDE 0816-1
Operating temp.
−40…+70 °C
Continuous thermal rating
Min. bend radius
10 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
Black PE outer
Extruded Black PE outer sheath
Standard
DIN VDE 0816-1
DIN VDE 0816-1

Typical values for this cable type, based on DIN VDE 0816-1 — confirmed in the datasheet and quotation for your order.

Application fit

Is A-2YF(L)2Y StIIIBd right for your machine?

A-2YF2Y StIIIBd Jelly-Filled Laminated-Sheath Outdoor Telecom Cable2Y StIIIBd) engineered to DIN VDE 0816-1 for 225 V peak service across -40 °C to +70 °C, featuring stranded copper conductor and black pe outer sheath with minimum bending radius 10 × OD.

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with DIN VDE 0816-1.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 10 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesRailway & Transit25 kV AC & 1.5/3 kV DC Railway Overhead CatenaryMainline High-Speed & Urban Metro TransitTrackside Signalling & Traction SubstationsRailway Rolling Stock & InfrastructureHigh-Voltage Grid & Substation Interconnects

Construction

Layer by layer

Shown: A-2YF(L)2Y StIIIBd (DIN VDE 0816-1) with stranded copper conductor, pe core insulation and black pe outer sheath (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per DIN VDE 0816-1DIN VDE 0816-1
2PE core insulationExtruded PE dielectric (individual core / group layer)DIN VDE 0816-1
3Paper tape and petrolatum fillingPaper tape and petrolatum filling (lapped tape)DIN VDE 0816-1
4Plastic-coated aluminium tapePlastic-coated aluminium tape metallic electromagnetic screen (lapped tape)DIN VDE 0816-1
5Black PE outer sheathExtruded Black PE outer sheath protective layer (continuous layer)DIN VDE 0816-1

A-2YF(L)2Y StIIIBd — Standard Execution

Built to DIN VDE 0816-1 with stranded copper conductor and black pe outer sheath

A-2YF(L)2Y StIIIBd — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per DIN VDE 0816-1

A-2YF(L)2Y StIIIBd — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0816-1. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
225 V peak (DIN VDE 0816-1)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per DIN VDE 0816-1
Primary insulation / dielectric
PE core insulation — Extruded PE dielectric (individual core / group layer)

Thermal

Continuous operating temperature
−40…+70 °C per DIN VDE 0816-1
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
Black PE outer sheath — Extruded Black PE outer sheath protective layer (continuous layer)
Minimum bending radius
10 × OD (installed / static routing)
Layer count & geometry
5 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with DIN VDE 0816-1
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
DIN VDE 0816-1
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
A-2YF(L)2Y StIIIBd
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard A-2YF(L)2Y StIIIBd cable configurations

Manufactured to DIN VDE 0816-1 in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
A-2YF(L)2Y StIIIBd Standard Construction Schedule (225 V peak · −40…+70 °C)
A-2YF(L)2Y StIIIBd 1×2×0.51×2×0.5 mm²6.45852
A-2YF(L)2Y StIIIBd 2×2×0.52×2×0.5 mm²9.211274
A-2YF(L)2Y StIIIBd 4×2×0.54×2×0.5 mm²11.417692
A-2YF(L)2Y StIIIBd 8×2×0.58×2×0.5 mm²14.8295118
A-2YF(L)2Y StIIIBd 12×2×0.512×2×0.5 mm²17.6420141
A-2YF(L)2Y StIIIBd 1×2×1.01×2×1.0 mm²7.68661
A-2YF(L)2Y StIIIBd 2×2×1.02×2×1.0 mm²11.016888
A-2YF(L)2Y StIIIBd 4×2×1.04×2×1.0 mm²13.5264108
A-2YF(L)2Y StIIIBd 8×2×1.08×2×1.0 mm²17.9465143
A-2YF(L)2Y StIIIBd 1×2×1.51×2×1.5 mm²8.511468
A-2YF(L)2Y StIIIBd 4×2×1.54×2×1.5 mm²15.2348122
A-2YF(L)2Y StIIIBd 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per DIN VDE 0816-1.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (DIN VDE 0816-1)DC resistance at 20 °C and geometry within DIN VDE 0816-1 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (DIN VDE 0816-1)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (DIN VDE 0816-1)Full compliance with DIN VDE 0816-1 across −40…+70 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0816-1 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX A-2YF(L)2Y StIIIBd <size> DIN VDE 0816-1 225 V peak CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define A-2YF(L)2Y StIIIBd (A-2YF(L)2Y StIIIBd Jelly-Filled Laminated-Sheath Outdoor Telecom Cable)?
A-2YF(L)2Y StIIIBd (A-2YF(L)2Y StIIIBd Jelly-Filled Laminated-Sheath Outdoor Telecom Cable) is manufactured in accordance with DIN VDE 0816-1 for 225 V peak service over -40 °C to +70 °C. Its 5-layer construction comprises stranded copper conductor, pe core insulation, paper tape and petrolatum filling, plastic-coated aluminium tape, black pe outer sheath.
What is the minimum bending radius and installation temperature for A-2YF(L)2Y StIIIBd?
The minimum installed bending radius for A-2YF(L)2Y StIIIBd is 10 × OD across its continuous operating temperature range of -40 °C to +70 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of A-2YF(L)2Y StIIIBd arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per DIN VDE 0816-1); (02) PE core insulation (Extruded PE dielectric (individual core / group layer)); (03) Paper tape and petrolatum filling (Paper tape and petrolatum filling (lapped tape)); (04) Plastic-coated aluminium tape (Plastic-coated aluminium tape metallic electromagnetic screen (lapped tape)); (05) Black PE outer sheath (Extruded Black PE outer sheath protective layer (continuous layer)).
What factory test certificates are supplied with A-2YF(L)2Y StIIIBd?
Every production drum or spool of A-2YF(L)2Y StIIIBd undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per DIN VDE 0816-1, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for A-2YF(L)2Y StIIIBd

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

A-2YF(L)2Y StIIIBd A-2YF2Y StIIIBd Jelly-Filled Laminated-Sheath Outdoor Telecom Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote