Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
4R3501 & 4XM554 (4×2.50 mm² HDPE-Insulated Tinned-Copper-Braid Shielded Water-Blocked PUR Subsea Power Cable) & 8A2041 (Cat.6 F/UTP PUR Underwater LAN Cable) (IEC 60228 / TIA-568, 0.6/1 kV, -30 °C to +80 °C, min. bend radius 10 × OD).
Typical values for this cable type, based on IEC 60228 / ANSI/TIA-568-C.2 Subsea Power & LAN — confirmed in the datasheet and quotation for your order.
Application fit
4R3501 & 4XM554 (4×2.50 mm² HDPE-Insulated Tinned-Copper-Braid Shielded Water-Blocked PUR Subsea Power Cable) & 8A2041 (Cat.6 F/UTP PUR Underwater LAN Cable) (IEC 60228 / TIA-568, 0.6/1 kV, -30 °C to +80 °C, min. bend radius 10 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: 4R3501 / 4XM554 & 8A2041 (IEC 60228 / ANSI/TIA-568-C.2 Subsea Power & LAN) featuring power conductors (4×2.50 mm² / cat.6 pairs), longitudinal water-swellable tape (swwb) and aramid strength braid & pur jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Power Conductors (4×2.50 mm² / Cat.6 Pairs) | Four 2.50 mm² stranded tinned copper conductors with 600/1,000 V HDPE insulation |
| 2 | Longitudinal Water-Swellable Tape (SWWB) | Water-blocking swellable tape preventing longitudinal seawater ingress |
| 3 | Tinned Copper Braid / Foil Shield (TCWB / OS) | High-coverage tinned copper wire braid (4XM554) or overall foil screen (4R3501 & 8A2041) |
| 4 | Aramid Strength Braid & PUR Jacket | 960 kg aramid strength braid (4XM554) + black subsea polyurethane jacket (Ø 10.0–13.0 mm) |
Built to IEC 60228 / ANSI/TIA-568-C.2 Subsea Power & LAN with power conductors (4×2.50 mm² / cat.6 pairs) and aramid strength braid & pur jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to IEC 60228 / ANSI/TIA-568-C.2 Subsea Power & LAN for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 4R3501 / 4XM554 & 8A2041 Construction Schedule (−30…+80 °C) | |||||||
| 4R3501 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| 4R3501 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| 4R3501 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −30…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −30…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60228 / ANSI/TIA-568-C.2 Subsea Power & LAN) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60228 / ANSI/TIA-568-C.2 Subsea Power & LAN tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60228 / ANSI/TIA-568-C.2 Subsea Power & LAN) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEC 60228 / ANSI/TIA-568-C.2 Subsea Power & LAN) | Verified submersion integrity, tensile load and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.