Product
Multitube Subsea BOP & Electro-Hydraulic Thermoplastic Hose Umbilical System (Series 53DM / 538DM , 55LT & 2245N API Spec 17E Compliant) (API Spec 17E / SAE 100R18, 0.6/1 kV, -30 °C to +70 °C, min. bend radius 12 × OD).
Typical values for this cable type, based on API Spec 17E / ISO 13628-5 / SAE J517 100R18 BOP Umbilical — confirmed in the datasheet and quotation for your order.
Application fit
Multitube Subsea BOP & Electro-Hydraulic Thermoplastic Hose Umbilical System (Series 53DM / 538DM , 55LT & 2245N API Spec 17E Compliant) (API Spec 17E / SAE 100R18, 0.6/1 kV, -30 °C to +70 °C, min. bend radius 12 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: 53DM / 55LT / 2245N (API Spec 17E / ISO 13628-5 / SAE J517 100R18 BOP Umbilical) featuring center velocity / hotline hose (1/2"), 53dm / 55lt / 2245n pilot hoses (6×1/4") and marine tpu / hdpe umbilical jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Center Velocity / Hotline Hose (1/2") | Low-expansion copolyester/PA11 core + aramid/wire braid + orange 538DM cover |
| 2 | 53DM / 55LT / 2245N Pilot Hoses (6×1/4") | 3,045–6,525 psi thermoplastic hoses (12,180–26,100 psi burst, ≤±2% length change) |
| 3 | Integrated Power & Signal Sub-Cables | 600–1,000 V shielded power and instrumentation cores cabled in outer valleys |
| 4 | Aramid / Steel Armour & Bedding | Polyester tape + aramid/steel tensile layer (≥1.5 collapse factor at 10,000 ft) |
| 5 | Marine TPU / HDPE Umbilical Jacket | Extruded black abrasion-resistant thermoplastic polyurethane overall jacket |
Built to API Spec 17E / ISO 13628-5 / SAE J517 100R18 BOP Umbilical with center velocity / hotline hose (1/2") and marine tpu / hdpe umbilical jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to API Spec 17E / ISO 13628-5 / SAE J517 100R18 BOP Umbilical for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 53DM / 55LT / 2245N Construction Schedule (−30…+70 °C) | |||||||
| 53DM 3-Part / Compact Assembly | Gas/Hydraulic Hose + Power + Comms/Coax | Helical cabled composite umbilical | 28.5 | 920 | 25.0 | 285 | |
| 53DM 4-Part / Standard Assembly | Dual Hose + 75 Ω Video Coax + Comms Pairs | Helical cabled composite umbilical | 36.0 | 1,540 | 48.0 | 360 | |
| 53DM Heavy Bell / Intervention | Multi-Hose + 3×Coax + Power/Signal Quads | Aramid-reinforced subsea umbilical | 54.0 | 3,420 | 90.0 | 540 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| Gas/Hydraulic Hose + Power + Comms/Coax | 4.95 | 0.6/1 kV + 35–240 bar Fluid | −30…+70 °C |
| Dual Hose + 75 Ω Video Coax + Comms Pairs | 3.30 | 0.6/1 kV + 35–240 bar Fluid | −30…+70 °C |
| Multi-Hose + 3×Coax + Power/Signal Quads | 1.91 | 0.6/1 kV + 100–240 bar Fluid | −30…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (API Spec 17E / ISO 13628-5 / SAE J517 100R18 BOP Umbilical) | DC resistance at 20 °C / optical attenuation and outer diameter within API Spec 17E / ISO 13628-5 / SAE J517 100R18 BOP Umbilical tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (API Spec 17E / ISO 13628-5 / SAE J517 100R18 BOP Umbilical) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (API Spec 17E / ISO 13628-5 / SAE J517 100R18 BOP Umbilical) | Verified submersion integrity, tensile load and thermal stability across −30…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.