500 & 500 S 0.6/1 kV 500m Submersible Sewage & Dewatering Pump CableVDE 0282 / AD8 500m · 0.6/1 kV · 500 m submersible sewage & mine dewatering pump

500 & 500 S (with KON Concentric Tinned Copper Braid Screen & Split Earth) 0.6/1 kV Heavy-Duty 500m Submersible Sewage & Dewatering Pump Cable (VDE 0282 / AD8 500m, 0.6/1 kV, -25 °C to +85 °C, min. bend radius 6 × OD).

Water-resistant
EMC screen
Oil-resistant
Flame-retardant
Order designation
500 4G16 mm²
Outer Ø ≈
21.8 mm
Net weight ≈
840 kg/km
Tensile rating ≈
2.4 kN
Core / stranding
IEC 60228 Class 5 flexible Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per VDE 0282 / AD8 500m
Operating temp.
−25…+85 °C
Continuous subsea & marine service
Min. bend radius
6 × OD
Dynamic sheave & fixed routing
Core / conductor
3×1.5–150 + 3×E
Class 5 SnCu + 3GI3 EPR
Outer protection
50 bar EPDM
Waterproof 500 m EPDM inner sheath
Standard
VDE 0282
DIN VDE 0282 / IEC 60332-1-2

Typical values for this cable type, based on DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump — confirmed in the datasheet and quotation for your order.

Application fit

Is 500 & 500 S right for your machine?

500 & 500 S (with KON Concentric Tinned Copper Braid Screen & Split Earth) 0.6/1 kV Heavy-Duty 500m Submersible Sewage & Dewatering Pump Cable (VDE 0282 / AD8 500m, 0.6/1 kV, -25 °C to +85 °C, min. bend radius 6 × OD).

Immersion & wet locations

Suitable

Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.

Free-hanging vertical run

Suitable

High-modulus conductor and elastomer construction supports vertical suspension in deep boreholes and pump risers.

Trailing & towing

Suitable

Tear- and abrasion-resistant rubber outer sheath handles mobile dewatering, dredger and portable pump deployment.

Fixed installation

Suitable

Suitable for permanent wet-well, treatment tank, geothermal borehole and submergedmanifold installations.

Energy chain / drag chain

Not suitable

Submersible rubber pump cable is not intended for high-acceleration automation drag chains.

Use Drag-Chain Control Cable
Typical machinesDeep-Well Potable Water PumpingMunicipal Sewage & Wastewater PlantsMine Dewatering & Slurry DredgingGeothermal, Spa & Pool Installations

Construction

Layer by layer

Shown: 500 & 500 S (DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump) featuring phase conductors (3×35 mm² tinned cu), symmetrical split earths (3×16/3 mm²) and sewage- & oil-resistant black cpe sheath (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Phase Conductors (3×35 mm² Tinned Cu)IEC 60228 Class 5 flexible tinned copper with EI7 / 3GI3 EPR (Brown, Black, Grey)
2Symmetrical Split Earths (3×16/3 mm²)Three Green/Yellow EPR-insulated tinned copper earth cores in outer valleys
3Waterproof EPDM Inner Sheath (500 m)Extruded waterproof EPDM inner bedding resisting 50 bar sewage/water pressure
4Concentric Tinned Copper Braid (KON)Overall tinned copper wire braid screen & earth-fault monitoring layer
5Sewage- & Oil-Resistant Black CPE SheathCross-linked CPE rubber outer jacket passing IEC 60811-404 oil & IEC 60332-1-2 flame

500 & 500 S — Standard Subsea & Marine Execution

Built to DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump with phase conductors (3×35 mm² tinned cu) and sewage- & oil-resistant black cpe sheath

500 & 500 S — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

500 & 500 S — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump)
Core / conductor construction
Phase Conductors (3×35 mm² Tinned Cu) — IEC 60228 Class 5 flexible tinned copper with EI7 / 3GI3 EPR (Brown, Black, Grey)
Primary dielectric / buffering
Symmetrical Split Earths (3×16/3 mm²) — Three Green/Yellow EPR-insulated tinned copper earth cores in outer valleys

Thermal

Continuous operating temperature
−25…+85 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Sewage- & Oil-Resistant Black CPE Sheath — Cross-linked CPE rubber outer jacket passing IEC 60811-404 oil & IEC 60332-1-2 flame
Minimum bending radius
6 × OD
Hydrostatic, tensile & crush duty
Concentric Tinned Copper Braid (KON) — Overall tinned copper wire braid screen & earth-fault monitoring layer

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
500 & 500 S
Sheath colour & metre marking
Continuous metre-marked black outer finish (50 bar EPDM + Black CPE)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard 500 & 500 S subsea & marine configurations

Manufactured to DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
500 & 500 S Construction Schedule (−25…+85 °C)
500 4G16 mm²4G16 mm² (3×16 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu21.88402.4130
500 4G35 mm²4G35 mm² (3×35 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu28.61,6205.2172
500 3×70 + 3G16 mm²3 × 70 mm² + 3G16 mm²IEC 60228 Class 5 flexible Cu/SnCu38.43,18010.5230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump)DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump)Verified submersion integrity, tensile load and thermal stability across −25…+85 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

VDE 0282 / AD8 500m CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 500 & 500 S VDE 0282 / AD8 500m 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define 500 & 500 S (500 & 500 S 0.6/1 kV 500m Submersible Sewage & Dewatering Pump Cable)?
500 & 500 S (500 & 500 S 0.6/1 kV 500m Submersible Sewage & Dewatering Pump Cable) is manufactured in accordance with DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump for 0.6/1 kV service over -25 °C to +85 °C. Its 5-layer construction comprises phase conductors (3×35 mm² tinned cu), symmetrical split earths (3×16/3 mm²) and sewage- & oil-resistant black cpe sheath.
What is the minimum bending radius and operating temperature range for 500 & 500 S?
The minimum bending radius for 500 & 500 S is 6 × OD across its continuous operating temperature range of -25 °C to +85 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of 500 & 500 S arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Phase Conductors (3×35 mm² Tinned Cu) — IEC 60228 Class 5 flexible tinned copper with EI7 / 3GI3 EPR (Brown, Black, Grey); (02) Symmetrical Split Earths (3×16/3 mm²) — Three Green/Yellow EPR-insulated tinned copper earth cores in outer valleys; (03) Waterproof EPDM Inner Sheath (500 m) — Extruded waterproof EPDM inner bedding resisting 50 bar sewage/water pressure; (04) Concentric Tinned Copper Braid (KON) — Overall tinned copper wire braid screen & earth-fault monitoring layer; (05) Sewage- & Oil-Resistant Black CPE Sheath — Cross-linked CPE rubber outer jacket passing IEC 60811-404 oil & IEC 60332-1-2 flame.
What factory test certificates are supplied with 500 & 500 S?
Every production drum of 500 & 500 S undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per DIN VDE 0282 / IEC 60332-1-2 / EN 60811-404 Sewage Pump, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for 500 & 500 S

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

500 & 500 S 0.6/1 kV 500m Submersible Sewage & Dewatering Pump Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote