VFD inverter to AC motor screened feeder
Engineered for medium-voltage PWM inverter drives, azimuth thrusters and main marine propulsion motors.
Product
3GSEGCH 6/10 kV (3.6/6 kV VFD) marine and offshore medium-voltage VFD motor power cable featuring Class 2 copper conductors, EPR dielectric stack, per-phase copper tape screen, overall concentric copper wire screen and LSZH ST8 sheath.
Typical values for this cable type, based on IEC 60092-354 / IEC 60092-350 — confirmed in the datasheet and quotation for your order.
Application fit
3GSEGCH 6/10 kV (3.6/6 kV VFD) marine and offshore medium-voltage VFD motor power cable featuring Class 2 copper conductors, EPR dielectric stack, per-phase copper tape screen, overall concentric copper wire screen and LSZH ST8 sheath.
Engineered for medium-voltage PWM inverter drives, azimuth thrusters and main marine propulsion motors.
Halogen-free flame-retardant ST8 polyolefin sheath qualified for shipboard and offshore platform routing.
Suitable for fixed marine bulkhead, cable ladder and engine room installation per IEC 60092-354.
Class 2 stranded conductors for fixed installation; select a Class 5 reeling cable for dynamic drums.
(N)7YRDGOEU-JConstruction
Shown: 3GSEGCH (IEC 60092-354 / IEC 60092-350) featuring phase conductors (3x70 mm²), mv epr dielectric stack and outer sheath (st8) (6-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Phase Conductors (3x70 mm²) | Class 2 circular stranded plain annealed copper phase conductors for marine medium-voltage propulsion & VFD drivesIEC 60092-354 / IEC 60092-350 |
| 2 | MV EPR Dielectric Stack | Triple-extruded inner semiconductive elastomer screen, 6/10 kV EPR primary dielectric, and outer semiconductive elastomer layerIEC 60092-354 / IEC 60092-350 |
| 3 | Individual Phase Screen | Two overlapped helically lapped plain annealed copper tapes over each phase core for symmetrical radial field controlIEC 60092-354 / IEC 60092-350 |
| 4 | Inner Covering | Extruded black halogen-free flame-retardant elastomeric inner bedding filling core intersticesIEC 60092-354 / IEC 60092-350 |
| 5 | Overall Concentric EMC Screen | Helically served plain copper wires with a transverse copper counter-helix providing 100% EMC containment for PWM invertersIEC 60092-354 / IEC 60092-350 |
| 6 | Outer Sheath (ST8) | Red flame-retardant, low-smoke zero-halogen (LSZH / SHF1) polyolefin outer sheath for shipboard & offshore installationsIEC 60092-354 / IEC 60092-350 |
Built to IEC 60092-354 / IEC 60092-350 with phase conductors (3x70 mm²) and outer sheath (st8)
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to IEC 60092-354 / IEC 60092-350 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 3GSEGCH Construction Schedule (−30…+90 °C) | |||||||
| 3GSEGCH 3×35 mm² 6/10 kV | 3 × 35 mm² | Class 2 Cu + dual Cu screen | 41.5 | 2,450 | 15.5 | 500 | |
| 3GSEGCH 3×50 mm² 6/10 kV | 3 × 50 mm² | Class 2 Cu + dual Cu screen | 44.8 | 3,020 | 22.0 | 540 | |
| 3GSEGCH 3×70 mm² 6/10 kV | 3 × 70 mm² | Class 2 Cu + dual Cu screen | 48.6 | 3,890 | 31.0 | 585 | |
| 3GSEGCH 3×95 mm² 6/10 kV | 3 × 95 mm² | Class 2 Cu + dual Cu screen | 52.8 | 4,860 | 42.0 | 635 | |
| 3GSEGCH 3×120 mm² 6/10 kV | 3 × 120 mm² | Class 2 Cu + dual Cu screen | 56.4 | 5,780 | 53.0 | 680 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 3 × 35 mm² | 0.52 | 6/10 kV / 155 A | −30…+90 °C |
| 3 × 50 mm² | 0.39 | 6/10 kV / 190 A | −30…+90 °C |
| 3 × 70 mm² | 0.27 | 6/10 kV / 235 A | −30…+90 °C |
| 3 × 95 mm² | 0.19 | 6/10 kV / 285 A | −30…+90 °C |
| 3 × 120 mm² | 0.15 | 6/10 kV / 330 A | −30…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (IEC 60092-354 / IEC 60092-350) | Electrical parameters and outer diameter within IEC 60092-354 / IEC 60092-350 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (IEC 60092-354 / IEC 60092-350) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (IEC 60092-354 / IEC 60092-350) | Verified structural and dielectric integrity across −30…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.