3GSEGCH 6/10 kV Marine & Offshore EMC VFD Motor CableIEC 60092-354 · 6/10 kV (3.6/6 kV VFD) · -30 °C to +90 °C dual-screened offshore VFD cable

3GSEGCH 6/10 kV (3.6/6 kV VFD) marine and offshore medium-voltage VFD motor power cable featuring Class 2 copper conductors, EPR dielectric stack, per-phase copper tape screen, overall concentric copper wire screen and LSZH ST8 sheath.

Low-EMC design
EMC screen
Flame-retardant
Water-resistant
Order designation
3GSEGCH 3×70 mm² 6/10 kV
Outer Ø ≈
48.6 mm
Weight ≈
3,890 kg/km
Tensile load ≈
31.0 kN
Core / stranding
Class 2 Cu + dual Cu screen
All sizes (5)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
6/10 kV
3.6/6 kV PWM VFD motor duty
Operating temp.
−30…+90 °C
Continuous thermal operating range
Min. bend radius
12–15 × OD
Installed / dynamic routing limit
Core / conductor
Class 2 Cu
3-phase stranded plain copper
Outer protection
SHF1 / ST8 LSZH
Red halogen-free marine sheath
Standard
IEC 60092-354
IEC 60092-354 / IEC 60092-350

Typical values for this cable type, based on IEC 60092-354 / IEC 60092-350 — confirmed in the datasheet and quotation for your order.

Application fit

Is 3GSEGCH right for your machine?

3GSEGCH 6/10 kV (3.6/6 kV VFD) marine and offshore medium-voltage VFD motor power cable featuring Class 2 copper conductors, EPR dielectric stack, per-phase copper tape screen, overall concentric copper wire screen and LSZH ST8 sheath.

VFD inverter to AC motor screened feeder

Suitable

Engineered for medium-voltage PWM inverter drives, azimuth thrusters and main marine propulsion motors.

Offshore platform & shipboard deck trays

Suitable

Halogen-free flame-retardant ST8 polyolefin sheath qualified for shipboard and offshore platform routing.

Fixed installation

Suitable

Suitable for fixed marine bulkhead, cable ladder and engine room installation per IEC 60092-354.

Motorised monospiral reel

Not suitable

Class 2 stranded conductors for fixed installation; select a Class 5 reeling cable for dynamic drums.

(N)7YRDGOEU-J
Typical machinesMarine & Offshore CableMarine Propulsion & Azimuth Thruster DrivesOffshore Drilling Rigs & FPSO Topside ModulesDredgers, Pipe-Laying & Heavy Marine VesselsHigh-Power Industrial MV Inverter Systems

Construction

Layer by layer

Shown: 3GSEGCH (IEC 60092-354 / IEC 60092-350) featuring phase conductors (3x70 mm²), mv epr dielectric stack and outer sheath (st8) (6-layer construction).

123456
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Phase Conductors (3x70 mm²)Class 2 circular stranded plain annealed copper phase conductors for marine medium-voltage propulsion & VFD drivesIEC 60092-354 / IEC 60092-350
2MV EPR Dielectric StackTriple-extruded inner semiconductive elastomer screen, 6/10 kV EPR primary dielectric, and outer semiconductive elastomer layerIEC 60092-354 / IEC 60092-350
3Individual Phase ScreenTwo overlapped helically lapped plain annealed copper tapes over each phase core for symmetrical radial field controlIEC 60092-354 / IEC 60092-350
4Inner CoveringExtruded black halogen-free flame-retardant elastomeric inner bedding filling core intersticesIEC 60092-354 / IEC 60092-350
5Overall Concentric EMC ScreenHelically served plain copper wires with a transverse copper counter-helix providing 100% EMC containment for PWM invertersIEC 60092-354 / IEC 60092-350
6Outer Sheath (ST8)Red flame-retardant, low-smoke zero-halogen (LSZH / SHF1) polyolefin outer sheath for shipboard & offshore installationsIEC 60092-354 / IEC 60092-350

3GSEGCH — Standard Execution

Built to IEC 60092-354 / IEC 60092-350 with phase conductors (3x70 mm²) and outer sheath (st8)

3GSEGCH — Custom Length & Configuration

Available in custom drum lengths, core counts or factory-terminated assemblies

3GSEGCH — Factory Routine Certified

Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60092-354 / IEC 60092-350. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
6/10 kV (IEC 60092-354 / IEC 60092-350)
Core / conductor construction
Phase Conductors (3x70 mm²) — Class 2 circular stranded plain annealed copper phase conductors for marine medium-voltage propulsion & VFD drives
Primary dielectric / insulation
MV EPR Dielectric Stack — Triple-extruded inner semiconductive elastomer screen, 6/10 kV EPR primary dielectric, and outer semiconductive elastomer layer

Thermal

Continuous operating temperature
−30…+90 °C (rated operating envelope)
Storage & transport temperature
−40…+80 °C on export drum or reel

Mechanical

Outer protection / sheath
Outer Sheath (ST8) — Red flame-retardant, low-smoke zero-halogen (LSZH / SHF1) polyolefin outer sheath for shipboard & offshore installations
Minimum bending radius
12–15 × OD
Structural layer count
6 concentric functional layers

Resistance

Environmental & chemical resistance
Industrial moisture, oils and mechanical wear per IEC 60092-354 / IEC 60092-350
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60092-354 / IEC 60092-350
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
3GSEGCH
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

5 standard 3GSEGCH configurations

Manufactured to IEC 60092-354 / IEC 60092-350 for heavy-duty industrial and specialty engineering systems.

Dimensions, tensile ratings & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Weight ≈
kg/km
Tensile load
kN ≈
Min. bend R
mm
Enquiry
3GSEGCH Construction Schedule (−30…+90 °C)
3GSEGCH 3×35 mm² 6/10 kV3 × 35 mm²Class 2 Cu + dual Cu screen41.52,45015.5500
3GSEGCH 3×50 mm² 6/10 kV3 × 50 mm²Class 2 Cu + dual Cu screen44.83,02022.0540
3GSEGCH 3×70 mm² 6/10 kV3 × 70 mm²Class 2 Cu + dual Cu screen48.63,89031.0585
3GSEGCH 3×95 mm² 6/10 kV3 × 95 mm²Class 2 Cu + dual Cu screen52.84,86042.0635
3GSEGCH 3×120 mm² 6/10 kV3 × 120 mm²Class 2 Cu + dual Cu screen56.45,78053.0680
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, cross-sections, sheath colours and factory-tested cut lengths available per IEC 60092-354 / IEC 60092-350.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & dimensional verification (IEC 60092-354 / IEC 60092-350)Electrical parameters and outer diameter within IEC 60092-354 / IEC 60092-350 tolerancesEvery manufactured drum / length
High-voltage dielectric & insulation resistance test (IEC 60092-354 / IEC 60092-350)Zero dielectric breakdown and verified insulation resistance over full lengthEvery manufactured drum / length
Sample tests
Thermal ageing, mechanical flexing & environmental qualification (IEC 60092-354 / IEC 60092-350)Verified structural and dielectric integrity across −30…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60092-354 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 3GSEGCH IEC 60092-354 6/10 kV CE
Delivery form
Heavy-duty export wooden/steel drums or factory-tested coils
Standard lengths
100 m, 250 m, 500 m, 1,000 m or custom cut-to-length reels
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-23
Updated
2026-10-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is 3GSEGCH engineered for?
3GSEGCH 6/10 kV (3.6/6 kV VFD) marine and offshore medium-voltage VFD motor power cable featuring Class 2 copper conductors, EPR dielectric stack, per-phase copper tape screen, overall concentric copper wire screen and LSZH ST8 sheath. It is built to IEC 60092-354 / IEC 60092-350 for marine propulsion & azimuth thruster drives and offshore drilling rigs & fpso topside modules.
What are the minimum bending radius and operating temperature range for 3GSEGCH?
The minimum bending radius for 3GSEGCH is 12–15 × OD across its continuous operating temperature range of -30 °C to +90 °C, ensuring mechanical and dielectric stability in industrial service.
How are the concentric layers of 3GSEGCH arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Phase Conductors (3x70 mm²) (Class 2 circular stranded plain annealed copper phase conductors for marine medium-voltage propulsion & VFD drives); (02) MV EPR Dielectric Stack (Triple-extruded inner semiconductive elastomer screen, 6/10 kV EPR primary dielectric, and outer semiconductive elastomer layer); (03) Individual Phase Screen (Two overlapped helically lapped plain annealed copper tapes over each phase core for symmetrical radial field control); (04) Inner Covering (Extruded black halogen-free flame-retardant elastomeric inner bedding filling core interstices); (05) Overall Concentric EMC Screen (Helically served plain copper wires with a transverse copper counter-helix providing 100% EMC containment for PWM inverters); (06) Outer Sheath (ST8) (Red flame-retardant, low-smoke zero-halogen (LSZH / SHF1) polyolefin outer sheath for shipboard & offshore installations).
What factory test certificates are supplied with 3GSEGCH?
Every production drum of 3GSEGCH undergoes routine electrical continuity, high-voltage dielectric and dimensional testing per IEC 60092-354 / IEC 60092-350, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for 3GSEGCH

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

3GSEGCH 6/10 kV Marine & Offshore EMC VFD Motor Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote