变频器(VFD)至交流电机屏蔽馈线
Engineered 适用于 中压 PWM inverter drives, azimuth thrusters 与 main marine propulsion motors.
产品主图
3GSEGCH 6/10 kV (3.6/6 kV VFD) marine 与 offshore 中压 VFD motor power cable featuring Class 2 铜 导体s, EPR dielectric stack, per-phase 铜 tape screen, overall concentric 铜 wire screen 与 LSZH ST8 sheath.
本电缆型号的典型值(依据 IEC 60092-354 / IEC 60092-350(技术规格))——具体订单参数将在技术规格书与报价单中确认。
应用工况
3GSEGCH 6/10 kV (3.6/6 kV VFD) marine 与 offshore 中压 VFD motor power cable featuring Class 2 铜 导体s, EPR dielectric stack, per-phase 铜 tape screen, overall concentric 铜 wire screen 与 LSZH ST8 sheath.
Engineered 适用于 中压 PWM inverter drives, azimuth thrusters 与 main marine propulsion motors.
无卤 flame-retardant ST8 polyolefin sheath qualified 适用于 shipboard 与 offshore platform routing.
按 IEC 60092-354 适用于船用舱壁、电缆梯架及机舱固定敷设。
Class 2 stranded 导体s 适用于 fixed installation; select a Class 5 卷筒电缆 适用于 dynamic drums.
(N)7YRDGOEU-J(技术规格)电缆结构
Shown: 3GSEGCH (IEC 60092-354 / IEC 60092-350) featuring phase 导体s (3x70 mm²), mv epr dielectric stack 与 外护套 (st8) (6-layer construction).
| # | 结构层 | 材料与参考标准 |
|---|---|---|
| 1 | Phase Conductors (3x70 mm²)(技术规格) | Class 2 circular stranded plain annealed 铜 phase 导体s 适用于 marine 中压 propulsion & VFD drivesIEC 60092-354 / IEC 60092-350(技术规格) |
| 2 | MV EPR Dielectric Stack(技术规格) | Triple-extruded inner semiconductive elastomer screen, 6/10 kV EPR primary dielectric, 与 outer semiconductive elastomer layerIEC 60092-354 / IEC 60092-350(技术规格) |
| 3 | 分相屏蔽(技术规格) | Two overlapped helically lapped plain annealed 铜 tapes over each phase core 适用于 symmetrical radial field controlIEC 60092-354 / IEC 60092-350(技术规格) |
| 4 | Inner Covering(技术规格) | Extruded black 无卤 flame-retardant elastomeric inner bedding filling core intersticesIEC 60092-354 / IEC 60092-350(技术规格) |
| 5 | Overall Concentric EMC Screen(技术规格) | Helically served plain 铜 wires 配有 a transverse 铜 counter-helix providing 100% EMC containment 适用于 PWM invertersIEC 60092-354 / IEC 60092-350(技术规格) |
| 6 | 外护套 (ST8) | Red flame-retardant, low-smoke zero-halogen (LSZH / SHF1) polyolefin 外护套 适用于 shipboard & offshore installationsIEC 60092-354 / IEC 60092-350(技术规格) |
Built 至 IEC 60092-354 / IEC 60092-350 配有 phase 导体s (3x70 mm²) 与 外护套 (st8)
Available in custom drum lengths, core counts or factory-terminated assemblies(技术规格)
Supplied 配有 EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
技术数据
规格尺寸
按 IEC 60092-354 / IEC 60092-350 制造,适用于重型工业与特种工程系统。
| 订货型号 | 规格配置 | 导体 / 绞合结构 | 近似外径 ≈ mm | 近似重量 ≈ kg/km | Tensile load kN ≈(技术规格) | 最小弯曲半径 mm | 询价 |
|---|---|---|---|---|---|---|---|
| 3GSEGCH Construction Schedule (−30…+90 °C)(技术规格) | |||||||
| 3GSEGCH 3×35 mm² 6/10 kV | 3 × 35 mm² | Class 2 Cu + dual Cu screen(技术规格) | 41.5 | 2,450 | 15.5 | 500 | |
| 3GSEGCH 3×50 mm² 6/10 kV | 3 × 50 mm² | Class 2 Cu + dual Cu screen(技术规格) | 44.8 | 3,020 | 22.0 | 540 | |
| 3GSEGCH 3×70 mm² 6/10 kV | 3 × 70 mm² | Class 2 Cu + dual Cu screen(技术规格) | 48.6 | 3,890 | 31.0 | 585 | |
| 3GSEGCH 3×95 mm² 6/10 kV | 3 × 95 mm² | Class 2 Cu + dual Cu screen(技术规格) | 52.8 | 4,860 | 42.0 | 635 | |
| 3GSEGCH 3×120 mm² 6/10 kV | 3 × 120 mm² | Class 2 Cu + dual Cu screen(技术规格) | 56.4 | 5,780 | 53.0 | 680 | |
| 规格配置 | 20 °C 最大直流电阻 / 衰减 Ω/km 或 dB/km (DC) | Rating / Capacity(技术规格) | 工作温度 |
|---|---|---|---|
| 3 × 35 mm² | 0.52 | 6/10 kV / 155 A(技术规格) | −30…+90 °C |
| 3 × 50 mm² | 0.39 | 6/10 kV / 190 A(技术规格) | −30…+90 °C |
| 3 × 70 mm² | 0.27 | 6/10 kV / 235 A(技术规格) | −30…+90 °C |
| 3 × 95 mm² | 0.19 | 6/10 kV / 285 A(技术规格) | −30…+90 °C |
| 3 × 120 mm² | 0.15 | 6/10 kV / 330 A(技术规格) | −30…+90 °C |
质量与认证
每根出厂长度均经例行试验,按批次进行抽样与型式试验,并随附 EN 10204 3.1 检验证书。
| 测试与检验 | 试验值/参考标准 | 频次 |
|---|---|---|
| 例行试验 | ||
| Conductor resistance & dimensional verification (IEC 60092-354 / IEC 60092-350)(技术规格) | Electrical parameters 与 outer diameter within IEC 60092-354 / IEC 60092-350 tolerances | 每一出厂盘长 / 交货长度 |
| High-voltage dielectric & 绝缘 resistance test (IEC 60092-354 / IEC 60092-350) | Zero dielectric breakdown 与 verified 绝缘 resistance over full length | 每一出厂盘长 / 交货长度 |
| 抽样试验 | ||
| Thermal ageing, mechanical flexing & environmental qualification (IEC 60092-354 / IEC 60092-350)(技术规格) | Verified structural 与 dielectric integrity across −30…+90 °C | 型式试验与定期批次抽检 |
标识与供货
护套印字
常见问题
未涵盖您的问题?欢迎发送图纸或工况,工程师将在 2 个工作小时内回复。
获取报价
所选规格与工况将一起带入下方询价表单。