YUTKGXFoyn Water-Blocked SWA Mine Shaft Telecom CableYUTKGXFoyn EMAG-approved longitudinally water-blocked (U) and round steel wire armoured (Fo) mining telecom cable per PN-G-90032 for wet vertical shafts (≤90°), with Ø 0.8 mm solid copper pairs, PE insulation (X), round SWA and grey FR-PVC sheath.

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per PN-G-90032 / ZN-TF-39 / IEC 60332-3-24 across -30 to +70 °C.

Water-resistant
Flame-retardant
Approved
Outdoor & humid
Order designation
YUTKGXFoyn 10×2×0.8 mm Shaft SWA
Outer Ø ≈
19.2 mm
Net weight ≈
710 kg/km
Tensile rating ≈
11.5 kN
Core / stranding
Class 1 solid Cu + Round SWA
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V
300 V wet vertical mine shaft telecom
Operating temp.
-30 to +70 °C
Continuous mining & industrial duty
Min. bend radius
12 × OD
Fixed installation / dynamic routing
Core / conductor
3–50×2×0.8 mm Cu
PN-EN 60228 Class 1 solid copper pairs
Outer protection
U + Fo SWA + yn
Swelling tape + round SWA + grey FR-PVC
Standard
PN-G-90032
PN-G-90032 / ZN-TF-39 / IEC 60332-3-24

Typical values for this cable type, based on PN-G-90032 / ZN-TF-39 / IEC 60332-3-24 — confirmed in the datasheet and quotation for your order.

Application fit

Is YUTKGXFoyn right for your machine?

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per PN-G-90032 / ZN-TF-39 / IEC 60332-3-24 across -30 to +70 °C.

Mine roadway & tunnel wall hangers

Suitable

Engineered for underground mining shafts, galleries and tunnel infrastructure per PN-G-90032 / ZN-TF-39 / IEC 60332-3-24.

Fixed installation

Suitable

Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 12 × OD.

Free-hanging vertical run

Suitable

Supports inclined roadway and vertical mine shaft suspension within rated kN load across -30 to +70 °C.

Typical machinesMining & TunnellingUnderground Coal & Hard-Rock MiningOpen-Cast Excavators, Draglines & ShovelsVertical Mine Shafts, Hoists & BoreholesTunneling, Mineral Processing & Slurry Plants

Construction

Layer by layer

Shown: YUTKGXFoyn (PN-G-90032 / ZN-TF-39 / IEC 60332-3-24) featuring solid copper conductors (10×2×0.8 mm), pe telecom insulation (x) and mining flame-retardant sheath (yn) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Solid Copper Conductors (10×2×0.8 mm)PN-EN 60228 Class 1 solid annealed bare copper (Ø 0.8 mm)
2PE Telecom Insulation (X)Solid communication-grade polyethylene (<55 nF/km) color-coded pairs
3Polyester Wrap & PVC Inner Sheath (Y)Polyester foil wrap + extruded black PVC inner bedding sheath
4Swelling Tape (U) & Round SWA (Fo)Water-blocking swellable tape + round galvanized steel wire armour (≤90°)
5Mining Flame-Retardant Sheath (yn)Grey high-oxygen-index (LOI ≥ 29%) Cat. C flame-retardant PVC jacket

YUTKGXFoyn — Standard Mining Execution

Built to PN-G-90032 / ZN-TF-39 / IEC 60332-3-24 with solid copper conductors (10×2×0.8 mm) and mining flame-retardant sheath (yn)

YUTKGXFoyn — Custom Drum Length & Gland Kit

Available in custom shaft/roadway drum lengths or pre-terminated assemblies

YUTKGXFoyn — Routine & Flame Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on PN-G-90032 / ZN-TF-39 / IEC 60332-3-24. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
300 V (PN-G-90032 / ZN-TF-39 / IEC 60332-3-24)
Core / conductor construction
Solid Copper Conductors (10×2×0.8 mm) — PN-EN 60228 Class 1 solid annealed bare copper (Ø 0.8 mm)
Primary dielectric / buffering
PE Telecom Insulation (X) — Solid communication-grade polyethylene (<55 nF/km) color-coded pairs

Thermal

Continuous operating temperature
-30 to +70 °C (mining & industrial service)
Short-circuit / peak thermal rating
Verified thermal stability per PN-G-90032 / ZN-TF-39 / IEC 60332-3-24
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Mining Flame-Retardant Sheath (yn) — Grey high-oxygen-index (LOI ≥ 29%) Cat. C flame-retardant PVC jacket
Minimum bending radius
12 × OD
Crush, impact & abrasion duty
Heavy-duty mining rock-cut, impact and tensile protection per PN-G-90032 / ZN-TF-39 / IEC 60332-3-24

Resistance

Flame retardancy & mine fire safety
Self-extinguishing / flame-retardant mining jacket per PN-G-90032 / ZN-TF-39 / IEC 60332-3-24
Mine water, oil & chemical resistance
Resistant to acidic mine water, hydraulic oils and abrasion per PN-G-90032 / ZN-TF-39 / IEC 60332-3-24
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
PN-G-90032 / ZN-TF-39 / IEC 60332-3-24
Flame & environmental test standards
IEC 60332 / MSHA / EN 60794 / IEC 60228
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
YUTKGXFoyn
Sheath colour & metre marking
Continuous metre-marked grey mining outer sheath
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard YUTKGXFoyn mining & industrial configurations

Manufactured to PN-G-90032 / ZN-TF-39 / IEC 60332-3-24 for underground mining, open-cast excavation, shaft and heavy industrial systems.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
YUTKGXFoyn Construction Schedule (-30 to +70 °C)
YUTKGXFoyn 5×2×0.8 mm Shaft SWA5 × 2 × 0.8 mm PE Pairs + UClass 1 solid Cu + Round SWA15.84958.5190
YUTKGXFoyn 10×2×0.8 mm Shaft SWA10 × 2 × 0.8 mm PE Pairs + UClass 1 solid Cu + Round SWA19.271011.5230
YUTKGXFoyn 20×2×0.8 mm Shaft SWA20 × 2 × 0.8 mm PE Pairs + UClass 1 solid Cu + Round SWA24.01,09016.0290
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per PN-G-90032 / ZN-TF-39 / IEC 60332-3-24.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (PN-G-90032 / ZN-TF-39 / IEC 60332-3-24)DC resistance at 20 °C / optical attenuation and outer diameter within PN-G-90032 / ZN-TF-39 / IEC 60332-3-24 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (PN-G-90032 / ZN-TF-39 / IEC 60332-3-24)Zero dielectric breakdown and verified insulation resistance over full production lengthEvery manufactured drum length
Sample tests
Flame propagation, mechanical crush & thermal ageing qualification (PN-G-90032 / ZN-TF-39 / IEC 60332-3-24)Verified flame retardancy, mechanical integrity and thermal endurance across -30 to +70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

PN-G-90032 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX YUTKGXFoyn PN-G-90032 300 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel mine reels
Standard lengths
500 m, 1,000 m or custom continuous shaft/reeling lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-24
Updated
2026-10-24

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define YUTKGXFoyn (YUTKGXFoyn Water-Blocked SWA Mine Shaft Telecom Cable)?
YUTKGXFoyn (YUTKGXFoyn Water-Blocked SWA Mine Shaft Telecom Cable) is manufactured in accordance with PN-G-90032 / ZN-TF-39 / IEC 60332-3-24 for 300 V duty over -30 to +70 °C. Its 5-layer construction comprises Solid Copper Conductors (10×2×0.8 mm), PE Telecom Insulation (X) and Mining Flame-Retardant Sheath (yn).
What is the minimum bending radius and operating temperature range for YUTKGXFoyn?
The minimum bending radius for YUTKGXFoyn is 12 × OD across its continuous operating temperature range of -30 to +70 °C, ensuring mechanical and dielectric reliability in mining and heavy industrial service.
How are the concentric layers of YUTKGXFoyn arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Solid Copper Conductors (10×2×0.8 mm) (PN-EN 60228 Class 1 solid annealed bare copper (Ø 0.8 mm)); (02) PE Telecom Insulation (X) (Solid communication-grade polyethylene (<55 nF/km) color-coded pairs); (03) Polyester Wrap & PVC Inner Sheath (Y) (Polyester foil wrap + extruded black PVC inner bedding sheath); (04) Swelling Tape (U) & Round SWA (Fo) (Water-blocking swellable tape + round galvanized steel wire armour (≤90°)); (05) Mining Flame-Retardant Sheath (yn) (Grey high-oxygen-index (LOI ≥ 29%) Cat. C flame-retardant PVC jacket).
What factory test certificates are supplied with YUTKGXFoyn?
Every production drum of YUTKGXFoyn undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per PN-G-90032 / ZN-TF-39 / IEC 60332-3-24, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for YUTKGXFoyn

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

YUTKGXFoyn Water-Blocked SWA Mine Shaft Telecom Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote