YKGSYFoyn 0.6/1 kV SWA Mine Shaft Control & Signalling CableYKGSYFoyn 0.6/1 kV round galvanized steel wire armoured (Fo) underground mining control and shaft signalling cable per ZN-CB-13:2002 for vertical shafts and >45° roadways, with numbered black PVC cores, Green/Yellow PE core and Cat. C FR-PVC sheath.

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24 across -30 to +70 °C.

Flame-retardant
Approved
Outdoor & humid
Ozone, UV & moisture
Order designation
YKGSYFoyn 6×2.5 + 2.5 mm² (0.6/1 kV)
Outer Ø ≈
19.8 mm
Net weight ≈
790 kg/km
Tensile rating ≈
11.5 kN
Core / stranding
Class 1 Cu + Round SWA
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
0.6/1 kV mine shaft & incline control
Operating temp.
-30 to +70 °C
Continuous mining & industrial duty
Min. bend radius
12 × OD
Fixed installation / dynamic routing
Core / conductor
4–61×1.5–10+żo
PN-EN 60228 Class 1/5 bare copper
Outer protection
Fo SWA + Grey yn
Round SWA + LOI ≥ 29% Cat. C FR-PVC
Standard
ZN-CB-13 / EMAG
ZN-CB-13:2002 / PN-EN 60228 / 60332-3-24

Typical values for this cable type, based on ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24 — confirmed in the datasheet and quotation for your order.

Application fit

Is YKGSYFoyn right for your machine?

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24 across -30 to +70 °C.

Mine roadway & tunnel wall hangers

Suitable

Engineered for underground mining shafts, galleries and tunnel infrastructure per ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24.

Fixed installation

Suitable

Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 12 × OD.

Free-hanging vertical run

Suitable

Supports inclined roadway and vertical mine shaft suspension within rated kN load across -30 to +70 °C.

Typical machinesMining & TunnellingUnderground Coal & Hard-Rock MiningOpen-Cast Excavators, Draglines & ShovelsVertical Mine Shafts, Hoists & BoreholesTunneling, Mineral Processing & Slurry Plants

Construction

Layer by layer

Shown: YKGSYFoyn (ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24) featuring conductors (6×2.5+2.5 mm²), pvc core insulation (y) and flame-retardant outer sheath (yn) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Conductors (6×2.5+2.5 mm²)PN-EN 60228 Class 1 solid bare copper (or Class 5 in YKGSLYFoyn)
2PVC Core Insulation (Y)Numbered black PVC control cores (1–6) + outer green/yellow PE core
3Inner Bedding Sheath (Y)Polyester tape wrap + extruded grey PVC inner cushioning sheath
4Round Steel Wire Armour (Fo)Helically applied galvanized round steel wires for shafts & >45° inclines
5Flame-Retardant Outer Sheath (yn)High-oxygen-index (LOI ≥ 29%) Cat. C flame-retardant mining PVC jacket

YKGSYFoyn — Standard Mining Execution

Built to ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24 with conductors (6×2.5+2.5 mm²) and flame-retardant outer sheath (yn)

YKGSYFoyn — Custom Drum Length & Gland Kit

Available in custom shaft/roadway drum lengths or pre-terminated assemblies

YKGSYFoyn — Routine & Flame Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24)
Core / conductor construction
Conductors (6×2.5+2.5 mm²) — PN-EN 60228 Class 1 solid bare copper (or Class 5 in YKGSLYFoyn)
Primary dielectric / buffering
PVC Core Insulation (Y) — Numbered black PVC control cores (1–6) + outer green/yellow PE core

Thermal

Continuous operating temperature
-30 to +70 °C (mining & industrial service)
Short-circuit / peak thermal rating
Verified thermal stability per ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Flame-Retardant Outer Sheath (yn) — High-oxygen-index (LOI ≥ 29%) Cat. C flame-retardant mining PVC jacket
Minimum bending radius
12 × OD
Crush, impact & abrasion duty
Heavy-duty mining rock-cut, impact and tensile protection per ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24

Resistance

Flame retardancy & mine fire safety
Self-extinguishing / flame-retardant mining jacket per ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24
Mine water, oil & chemical resistance
Resistant to acidic mine water, hydraulic oils and abrasion per ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24
Flame & environmental test standards
IEC 60332 / MSHA / EN 60794 / IEC 60228
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
YKGSYFoyn
Sheath colour & metre marking
Continuous metre-marked grey mining outer sheath
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard YKGSYFoyn mining & industrial configurations

Manufactured to ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24 for underground mining, open-cast excavation, shaft and heavy industrial systems.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
YKGSYFoyn Construction Schedule (-30 to +70 °C)
YKGSYFoyn 6×2.5 + 2.5 mm² (0.6/1 kV)6 × 2.5 mm² + 1 × 2.5 żoClass 1 Cu + Round SWA19.879011.5240
YKGSYFoyn 12×2.5 + 2.5 mm² (0.6/1 kV)12 × 2.5 mm² + 1 × 2.5 żoClass 1 Cu + Round SWA24.61,24016.5295
YKGSYFoyn 24×1.5 + 1.5 mm² (0.6/1 kV)24 × 1.5 mm² + 1 × 1.5 żoClass 1 Cu + Round SWA27.41,49019.0330
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24)DC resistance at 20 °C / optical attenuation and outer diameter within ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24)Zero dielectric breakdown and verified insulation resistance over full production lengthEvery manufactured drum length
Sample tests
Flame propagation, mechanical crush & thermal ageing qualification (ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24)Verified flame retardancy, mechanical integrity and thermal endurance across -30 to +70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ZN-CB-13 / EMAG CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX YKGSYFoyn ZN-CB-13 / EMAG 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel mine reels
Standard lengths
500 m, 1,000 m or custom continuous shaft/reeling lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-24
Updated
2026-10-24

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define YKGSYFoyn (YKGSYFoyn 0.6/1 kV SWA Mine Shaft Control & Signalling Cable)?
YKGSYFoyn (YKGSYFoyn 0.6/1 kV SWA Mine Shaft Control & Signalling Cable) is manufactured in accordance with ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24 for 0.6/1 kV duty over -30 to +70 °C. Its 5-layer construction comprises Conductors (6×2.5+2.5 mm²), PVC Core Insulation (Y) and Flame-Retardant Outer Sheath (yn).
What is the minimum bending radius and operating temperature range for YKGSYFoyn?
The minimum bending radius for YKGSYFoyn is 12 × OD across its continuous operating temperature range of -30 to +70 °C, ensuring mechanical and dielectric reliability in mining and heavy industrial service.
How are the concentric layers of YKGSYFoyn arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Conductors (6×2.5+2.5 mm²) (PN-EN 60228 Class 1 solid bare copper (or Class 5 in YKGSLYFoyn)); (02) PVC Core Insulation (Y) (Numbered black PVC control cores (1–6) + outer green/yellow PE core); (03) Inner Bedding Sheath (Y) (Polyester tape wrap + extruded grey PVC inner cushioning sheath); (04) Round Steel Wire Armour (Fo) (Helically applied galvanized round steel wires for shafts & >45° inclines); (05) Flame-Retardant Outer Sheath (yn) (High-oxygen-index (LOI ≥ 29%) Cat. C flame-retardant mining PVC jacket).
What factory test certificates are supplied with YKGSYFoyn?
Every production drum of YKGSYFoyn undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per ZN-CB-13:2002 / PN-EN 60228 / IEC 60332-3-24, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for YKGSYFoyn

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

YKGSYFoyn 0.6/1 kV SWA Mine Shaft Control & Signalling Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote