Contact

YKGSLYkonyn 0.6/1 kV Screened Underground Mining Control CableYKGSLYkonyn 300/500 V and 0.6/1 kV flexible double-sheathed, tinned-copper-braid screened (kon) underground mining control and telemetry cable per ZN-CB-14:2002, with Class 5 copper cores, Green/Yellow PE core and high-LOI Cat. C FR-PVC sheath.

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24 across -30 to +70 °C.

EMC screen
Low-EMC design
Flame-retardant
Oil-resistant
Order designation
YKGSLYkonyn 6×1.5 + 1.5 mm² (0.6/1 kV)
Outer Ø ≈
15.2 mm
Net weight ≈
345 kg/km
Tensile rating ≈
1.1 kN
Core / stranding
Class 5 bare Cu (1+6 lay)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
300/500 V & 0.6/1 kV mining control
Operating temp.
-30 to +70 °C
Continuous mining & industrial duty
Min. bend radius
10 × OD
Fixed installation / dynamic routing
Core / conductor
4–37×1.0–4.0+żo
PN-EN 60228 Class 5 flexible copper
Outer protection
kon + Grey yn
SnCu braid + LOI ≥ 29% Cat. C FR-PVC
Standard
ZN-CB-14 / EMAG
ZN-CB-14:2002 / PN-EN 60228 / 60332-3-24

Typical values for this cable type, based on ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24 — confirmed in the datasheet and quotation for your order.

Application fit

Is YKGSLYkonyn right for your machine?

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24 across -30 to +70 °C.

Mine roadway & tunnel wall hangers

Suitable

Engineered for underground mining shafts, galleries and tunnel infrastructure per ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24.

Fixed installation

Suitable

Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 10 × OD.

Free-hanging vertical run

Suitable

Supports inclined roadway and vertical mine shaft suspension within rated kN load across -30 to +70 °C.

Typical machinesMining & TunnellingUnderground Coal & Hard-Rock MiningOpen-Cast Excavators, Draglines & ShovelsVertical Mine Shafts, Hoists & BoreholesTunneling, Mineral Processing & Slurry Plants

Construction

Layer by layer

Shown: YKGSLYkonyn (ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24) featuring control conductors (6×1.5+1.5 mm²), pvc core insulation (y) and mining outer sheath (yn) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Control Conductors (6×1.5+1.5 mm²)PN-EN 60228 Class 5 flexible bare annealed copper (1+6 concentric lay)
2PVC Core Insulation (Y)Numbered black PVC control cores + outer green/yellow protective core
3Inner Bedding Sheath (Y)Extruded black inner PVC sheath for radial crush and moisture protection
4Overall Braid Screen (kon)Tinned copper wire braid shield (≥70% optical coverage)
5Mining Outer Sheath (yn)Grey (or Ex-i Blue) high-LOI (LOI ≥ 29%) Cat. C flame-retardant PVC jacket

YKGSLYkonyn — Standard Mining Execution

Built to ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24 with control conductors (6×1.5+1.5 mm²) and mining outer sheath (yn)

YKGSLYkonyn — Custom Drum Length & Gland Kit

Available in custom shaft/roadway drum lengths or pre-terminated assemblies

YKGSLYkonyn — Routine & Flame Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24)
Core / conductor construction
Control Conductors (6×1.5+1.5 mm²) — PN-EN 60228 Class 5 flexible bare annealed copper (1+6 concentric lay)
Primary dielectric / buffering
PVC Core Insulation (Y) — Numbered black PVC control cores + outer green/yellow protective core

Thermal

Continuous operating temperature
-30 to +70 °C (mining & industrial service)
Short-circuit / peak thermal rating
Verified thermal stability per ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Mining Outer Sheath (yn) — Grey (or Ex-i Blue) high-LOI (LOI ≥ 29%) Cat. C flame-retardant PVC jacket
Minimum bending radius
10 × OD
Crush, impact & abrasion duty
Heavy-duty mining rock-cut, impact and tensile protection per ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24

Resistance

Flame retardancy & mine fire safety
Self-extinguishing / flame-retardant mining jacket per ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24
Mine water, oil & chemical resistance
Resistant to acidic mine water, hydraulic oils and abrasion per ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24
Flame & environmental test standards
IEC 60332 / MSHA / EN 60794 / IEC 60228
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
YKGSLYkonyn
Sheath colour & metre marking
Continuous metre-marked grey mining outer sheath
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard YKGSLYkonyn mining & industrial configurations

Manufactured to ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24 for underground mining, open-cast excavation, shaft and heavy industrial systems.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
YKGSLYkonyn Construction Schedule (-30 to +70 °C)
YKGSLYkonyn 6×1.5 + 1.5 mm² (0.6/1 kV)6 × 1.5 mm² + 1 × 1.5 żoClass 5 bare Cu (1+6 lay)15.23451.1155
YKGSLYkonyn 12×1.5 + 1.5 mm² (0.6/1 kV)12 × 1.5 mm² + 1 × 1.5 żoClass 5 bare Cu19.45402.0195
YKGSLYkonyn 18×2.5 + 2.5 mm² (0.6/1 kV)18 × 2.5 mm² + 1 × 2.5 żoClass 5 bare Cu25.69854.8255
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24)DC resistance at 20 °C / optical attenuation and outer diameter within ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24)Zero dielectric breakdown and verified insulation resistance over full production lengthEvery manufactured drum length
Sample tests
Flame propagation, mechanical crush & thermal ageing qualification (ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24)Verified flame retardancy, mechanical integrity and thermal endurance across -30 to +70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ZN-CB-14 / EMAG CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX YKGSLYkonyn ZN-CB-14 / EMAG 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel mine reels
Standard lengths
500 m, 1,000 m or custom continuous shaft/reeling lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-24
Updated
2026-10-24

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define YKGSLYkonyn (YKGSLYkonyn 0.6/1 kV Screened Underground Mining Control Cable)?
YKGSLYkonyn (YKGSLYkonyn 0.6/1 kV Screened Underground Mining Control Cable) is manufactured in accordance with ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24 for 0.6/1 kV duty over -30 to +70 °C. Its 5-layer construction comprises Control Conductors (6×1.5+1.5 mm²), PVC Core Insulation (Y) and Mining Outer Sheath (yn).
What is the minimum bending radius and operating temperature range for YKGSLYkonyn?
The minimum bending radius for YKGSLYkonyn is 10 × OD across its continuous operating temperature range of -30 to +70 °C, ensuring mechanical and dielectric reliability in mining and heavy industrial service.
How are the concentric layers of YKGSLYkonyn arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Control Conductors (6×1.5+1.5 mm²) (PN-EN 60228 Class 5 flexible bare annealed copper (1+6 concentric lay)); (02) PVC Core Insulation (Y) (Numbered black PVC control cores + outer green/yellow protective core); (03) Inner Bedding Sheath (Y) (Extruded black inner PVC sheath for radial crush and moisture protection); (04) Overall Braid Screen (kon) (Tinned copper wire braid shield (≥70% optical coverage)); (05) Mining Outer Sheath (yn) (Grey (or Ex-i Blue) high-LOI (LOI ≥ 29%) Cat. C flame-retardant PVC jacket).
What factory test certificates are supplied with YKGSLYkonyn?
Every production drum of YKGSLYkonyn undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per ZN-CB-14:2002 / PN-EN 60228 / IEC 60332-3-24, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for YKGSLYkonyn

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

YKGSLYkonyn 0.6/1 kV Screened Underground Mining Control Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote