Switchgear & control cabinet wiring
UL AWM Style 1813 recognized for 3000 VAC internal wiring of electronic appliances, HV ballasts and switchgear.
Product
UL 1813 3000 VAC +200 °C high-voltage appliance and equipment hook-up wire combining concentric stranded tinned copper conductors with a 0.64 mm (25 mil) single-wall extruded FEP fluoropolymer insulation.
Typical values for this cable type, based on UL AWM Style 1813 / UL 758 — confirmed in the datasheet and quotation for your order.
Application fit
UL 1813 3000 VAC +200 °C high-voltage appliance and equipment hook-up wire combining concentric stranded tinned copper conductors with a 0.64 mm (25 mil) single-wall extruded FEP fluoropolymer insulation.
UL AWM Style 1813 recognized for 3000 VAC internal wiring of electronic appliances, HV ballasts and switchgear.
Continuous −80…+200 °C fluoropolymer thermal rating with UL VW-1 flame resistance and solder-iron immunity.
Resists transformer oils, varnishes, baking cycles and chemical solvents in motor and coil terminations.
Single-core internal appliance hook-up wire per UL 758; not for external mechanical reeling.
(N)7YRDGOEU-JConstruction
Shown: UL 1813 (UL AWM Style 1813 / UL 758) featuring stranded conductor (22 awg), tin surface plating and 3 kv fep primary insulation (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Conductor (22 AWG) | 22 AWG (7 x 0.254 mm / 0.355 mm², OD 0.76 mm) concentric stranded annealed copper conductor for compact HV equipment wiringUL AWM Style 1813 / UL 758 |
| 2 | Tin Surface Plating | Uniform electrolytic tin coating over each copper strand ensuring solderability and oxidation resistance up to 200 °CUL AWM Style 1813 / UL 758 |
| 3 | 3 kV FEP Primary Insulation | Single-wall extruded fluorinated ethylene propylene (FEP) fluoropolymer insulation (min. wall 0.64 mm / 25 mil, OD 2.13 mm) rated 3000 VAC, 200 °C, VW-1UL AWM Style 1813 / UL 758 |
Built to UL AWM Style 1813 / UL 758 with stranded conductor (22 awg) and 3 kv fep primary insulation
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to UL AWM Style 1813 / UL 758 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| UL 1813 Construction Schedule (−80…+200 °C) | |||||||
| UL 1813 24 AWG (7/32) 3000 VAC FEP | 1 × 24 AWG (0.23 mm²) | 7/0.203 mm tinned Cu + FEP | 1.9 | 6 | 0.1 | 10 | |
| UL 1813 22 AWG (7/30) 3000 VAC FEP | 1 × 22 AWG (0.35 mm²) | 7/0.254 mm tinned Cu + FEP | 2.1 | 8 | 0.1 | 11 | |
| UL 1813 20 AWG (19/32) 3000 VAC FEP | 1 × 20 AWG (0.61 mm²) | 19/0.203 mm tinned Cu + FEP | 2.3 | 11 | 0.2 | 12 | |
| UL 1813 18 AWG (19/30) 3000 VAC FEP | 1 × 18 AWG (0.96 mm²) | 19/0.254 mm tinned Cu + FEP | 2.5 | 15 | 0.3 | 13 | |
| UL 1813 16 AWG (19/29) 3000 VAC FEP | 1 × 16 AWG (1.23 mm²) | 19/0.287 mm tinned Cu + FEP | 2.8 | 19 | 0.4 | 14 | |
| UL 1813 14 AWG (19/27) 3000 VAC FEP | 1 × 14 AWG (1.94 mm²) | 19/0.361 mm tinned Cu + FEP | 3.2 | 27 | 0.6 | 16 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 24 AWG (0.23 mm²) | 84.20 | 3000 VAC / 6.5 A | −80…+200 °C |
| 22 AWG (0.35 mm²) | 54.30 | 3000 VAC / 9.0 A | −80…+200 °C |
| 20 AWG (0.61 mm²) | 32.10 | 3000 VAC / 13.0 A | −80…+200 °C |
| 18 AWG (0.96 mm²) | 20.60 | 3000 VAC / 18.0 A | −80…+200 °C |
| 16 AWG (1.23 mm²) | 15.80 | 3000 VAC / 22.0 A | −80…+200 °C |
| 14 AWG (1.94 mm²) | 9.90 | 3000 VAC / 30.0 A | −80…+200 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (UL AWM Style 1813 / UL 758) | Electrical parameters and outer diameter within UL AWM Style 1813 / UL 758 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (UL AWM Style 1813 / UL 758) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (UL AWM Style 1813 / UL 758) | Verified structural and dielectric integrity across −80…+200 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.