UL 1813 3000 VAC 200 °C FEP hook-up wireUL AWM 18133000 VAC / +200 °CFEP Fluoropolymer

UL 1813 3000 VAC 200 °C FEP High-Voltage Hook-Up WireUL AWM Style 1813 / CSA · 3000 VAC · -80 °C to +200 °C single-wall FEP fluoropolymer lead wire

UL 1813 3000 VAC +200 °C high-voltage appliance and equipment hook-up wire combining concentric stranded tinned copper conductors with a 0.64 mm (25 mil) single-wall extruded FEP fluoropolymer insulation.

Flame-retardant
Oil-resistant
Approved
Ozone, UV & moisture
Order designation
UL 1813 22 AWG (7/30) 3000 VAC FEP
Outer Ø ≈
2.1 mm
Weight ≈
8 kg/km
Tensile load ≈
0.1 kN
Core / stranding
7/0.254 mm tinned Cu + FEP
All sizes (6)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
3000 VAC
6000 VAC spark test · UL 1813
Operating temp.
−80…+200 °C
Continuous thermal operating range
Min. bend radius
5 × OD
Installed / dynamic routing limit
Core / conductor
24–10 AWG Cu
Concentric stranded tinned copper
Outer protection
0.64 mm FEP
UL VW-1 fluoropolymer wall
Standard
UL AWM 1813
UL AWM Style 1813 / UL 758

Typical values for this cable type, based on UL AWM Style 1813 / UL 758 — confirmed in the datasheet and quotation for your order.

Application fit

Is UL 1813 right for your machine?

UL 1813 3000 VAC +200 °C high-voltage appliance and equipment hook-up wire combining concentric stranded tinned copper conductors with a 0.64 mm (25 mil) single-wall extruded FEP fluoropolymer insulation.

Switchgear & control cabinet wiring

Suitable

UL AWM Style 1813 recognized for 3000 VAC internal wiring of electronic appliances, HV ballasts and switchgear.

Furnace, kiln & high-temp zone

Suitable

Continuous −80…+200 °C fluoropolymer thermal rating with UL VW-1 flame resistance and solder-iron immunity.

Motor stator, traction & converter leads

Suitable

Resists transformer oils, varnishes, baking cycles and chemical solvents in motor and coil terminations.

Motorised monospiral reel

Not suitable

Single-core internal appliance hook-up wire per UL 758; not for external mechanical reeling.

(N)7YRDGOEU-J
Typical machinesAerospace & AvionicsHigh-Voltage Transformers, Igniters & Lamp BallastsMedical Diagnostic, Sterilization & Laboratory CabinetsIndustrial Ovens, Commercial Kitchen & Heating EquipmentPower Electronics, Inverters & Switchgear Harnessing

Construction

Layer by layer

Shown: UL 1813 (UL AWM Style 1813 / UL 758) featuring stranded conductor (22 awg), tin surface plating and 3 kv fep primary insulation (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded Conductor (22 AWG)22 AWG (7 x 0.254 mm / 0.355 mm², OD 0.76 mm) concentric stranded annealed copper conductor for compact HV equipment wiringUL AWM Style 1813 / UL 758
2Tin Surface PlatingUniform electrolytic tin coating over each copper strand ensuring solderability and oxidation resistance up to 200 °CUL AWM Style 1813 / UL 758
33 kV FEP Primary InsulationSingle-wall extruded fluorinated ethylene propylene (FEP) fluoropolymer insulation (min. wall 0.64 mm / 25 mil, OD 2.13 mm) rated 3000 VAC, 200 °C, VW-1UL AWM Style 1813 / UL 758

UL 1813 — Standard Execution

Built to UL AWM Style 1813 / UL 758 with stranded conductor (22 awg) and 3 kv fep primary insulation

UL 1813 — Custom Length & Configuration

Available in custom drum lengths, core counts or factory-terminated assemblies

UL 1813 — Factory Routine Certified

Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL AWM Style 1813 / UL 758. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
3000 VAC (UL AWM Style 1813 / UL 758)
Core / conductor construction
Stranded Conductor (22 AWG) — 22 AWG (7 x 0.254 mm / 0.355 mm², OD 0.76 mm) concentric stranded annealed copper conductor for compact HV equipment wiring
Primary dielectric / insulation
Tin Surface Plating — Uniform electrolytic tin coating over each copper strand ensuring solderability and oxidation resistance up to 200 °C

Thermal

Continuous operating temperature
−80…+200 °C (rated operating envelope)
Storage & transport temperature
−40…+80 °C on export drum or reel

Mechanical

Outer protection / sheath
3 kV FEP Primary Insulation — Single-wall extruded fluorinated ethylene propylene (FEP) fluoropolymer insulation (min. wall 0.64 mm / 25 mil, OD 2.13 mm) rated 3000 VAC, 200 °C, VW-1
Minimum bending radius
5 × OD
Structural layer count
3 concentric functional layers

Resistance

Environmental & chemical resistance
Industrial moisture, oils and mechanical wear per UL AWM Style 1813 / UL 758
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
UL AWM Style 1813 / UL 758
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
UL 1813
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

6 standard UL 1813 configurations

Manufactured to UL AWM Style 1813 / UL 758 for heavy-duty industrial and specialty engineering systems.

Dimensions, tensile ratings & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Weight ≈
kg/km
Tensile load
kN ≈
Min. bend R
mm
Enquiry
UL 1813 Construction Schedule (−80…+200 °C)
UL 1813 24 AWG (7/32) 3000 VAC FEP1 × 24 AWG (0.23 mm²)7/0.203 mm tinned Cu + FEP1.960.110
UL 1813 22 AWG (7/30) 3000 VAC FEP1 × 22 AWG (0.35 mm²)7/0.254 mm tinned Cu + FEP2.180.111
UL 1813 20 AWG (19/32) 3000 VAC FEP1 × 20 AWG (0.61 mm²)19/0.203 mm tinned Cu + FEP2.3110.212
UL 1813 18 AWG (19/30) 3000 VAC FEP1 × 18 AWG (0.96 mm²)19/0.254 mm tinned Cu + FEP2.5150.313
UL 1813 16 AWG (19/29) 3000 VAC FEP1 × 16 AWG (1.23 mm²)19/0.287 mm tinned Cu + FEP2.8190.414
UL 1813 14 AWG (19/27) 3000 VAC FEP1 × 14 AWG (1.94 mm²)19/0.361 mm tinned Cu + FEP3.2270.616
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, cross-sections, sheath colours and factory-tested cut lengths available per UL AWM Style 1813 / UL 758.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & dimensional verification (UL AWM Style 1813 / UL 758)Electrical parameters and outer diameter within UL AWM Style 1813 / UL 758 tolerancesEvery manufactured drum / length
High-voltage dielectric & insulation resistance test (UL AWM Style 1813 / UL 758)Zero dielectric breakdown and verified insulation resistance over full lengthEvery manufactured drum / length
Sample tests
Thermal ageing, mechanical flexing & environmental qualification (UL AWM Style 1813 / UL 758)Verified structural and dielectric integrity across −80…+200 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL AWM 1813 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX UL 1813 UL AWM 1813 3000 VAC CE
Delivery form
Heavy-duty export wooden/steel drums or factory-tested coils
Standard lengths
100 m, 250 m, 500 m, 1,000 m or custom cut-to-length reels
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-23
Updated
2026-10-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is UL 1813 engineered for?
UL 1813 3000 VAC +200 °C high-voltage appliance and equipment hook-up wire combining concentric stranded tinned copper conductors with a 0.64 mm (25 mil) single-wall extruded FEP fluoropolymer insulation. It is built to UL AWM Style 1813 / UL 758 for high-voltage transformers, igniters & lamp ballasts and medical diagnostic, sterilization & laboratory cabinets.
What are the minimum bending radius and operating temperature range for UL 1813?
The minimum bending radius for UL 1813 is 5 × OD across its continuous operating temperature range of -80 °C to +200 °C, ensuring mechanical and dielectric stability in industrial service.
How are the concentric layers of UL 1813 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded Conductor (22 AWG) (22 AWG (7 x 0.254 mm / 0.355 mm², OD 0.76 mm) concentric stranded annealed copper conductor for compact HV equipment wiring); (02) Tin Surface Plating (Uniform electrolytic tin coating over each copper strand ensuring solderability and oxidation resistance up to 200 °C); (03) 3 kV FEP Primary Insulation (Single-wall extruded fluorinated ethylene propylene (FEP) fluoropolymer insulation (min. wall 0.64 mm / 25 mil, OD 2.13 mm) rated 3000 VAC, 200 °C, VW-1).
What factory test certificates are supplied with UL 1813?
Every production drum of UL 1813 undergoes routine electrical continuity, high-voltage dielectric and dimensional testing per UL AWM Style 1813 / UL 758, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for UL 1813

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

UL 1813 3000 VAC 200 °C FEP High-Voltage Hook-Up Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote