Immersion & wet locations
Special hydrophobic TPE outer jacket (< 0.05 % water absorption) withstands daily +80 °C high-pressure washdown and ECOLAB CIP foams.
Product
ROBUST 210 (unscreened) and 215C (Cu-braid screened) halogen-free food and beverage control cable (300/500 V, 4,000 V test, -50 to +80 °C) with PP/TPE core insulation and an ECOLAB-certified TPE jacket resistant to hot washdown and bio-oils.
Typical values for this cable type, based on VDE 0250 / EN 50525 / ECOLAB Food & Beverage Washdown Control Specification — confirmed in the datasheet and quotation for your order.
Application fit
Select ROBUST 210 (unscreened) or 215C (screened) for dairy, meat-packing, brewery, and bottling lines exposed to daily high-pressure hot-water and ECOLAB chemical washdowns.
Special hydrophobic TPE outer jacket (< 0.05 % water absorption) withstands daily +80 °C high-pressure washdown and ECOLAB CIP foams.
Special non-polar TPE outer jacket resists dairy butterfat, blood/tallow, rapeseed/soybean bio-oils, and cutting emulsions.
Choose 215C (≥ 80 % Sn-Cu braid screen) for VFD conveyor drives, load cells, and flowmeters in washdown zones.
TPE thermoplastic elastomer is rated to +80 °C; for +180 °C baking ovens or autoclaves, use Besilen ESD or silicone control cable.
Use Besilen ESD for +180 °C siliconeConstruction
210 / 215C food-grade washdown construction: IEC 60228 Class 5 bare copper conductors, low-capacitance modified PP/TPE core insulation (black numbered + GNYE), optional tinned copper braid screen (215C), and jet-black chemical-resistant TPE jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Fine-stranded Class 5 copper | Flexible annealed bare copper wire (IEC 60228 / DIN VDE 0295 Class 5)Supple routing along stainless-steel hygienic cable trays and filling carousels |
| 2 | Modified PP/TPE core insulation | Halogen-free, low-capacitance polypropylene/TPE compound (black cores with white numbers + GNYE)10× higher insulation resistance than PVC and tested at 4,000 V AC |
| 3 | Tinned copper braid screen (215C) | 215C version only: braided tinned copper wires (≥ 80 % optical coverage) over PTFE/fleece wrapShields weighing cells, dosing pumps, and VFD signals against electromagnetic interference |
| 4 | Bio-oil & washdown TPE outer jacket | Special cross-linked/thermoplastic elastomer compound (black, RAL 9005, halogen-free & UV-resistant)Certified resistant to ECOLAB detergents, lactic/citric acids, caustic soda, and vegetable oils |
Unscreened TPE bio-oil and ECOLAB washdown-resistant food & beverage control cable
Tinned-copper-braid screened ('C') TPE food & beverage washdown control cable for EMC-sensitive zones
Technical data
Sizes
Engineering dimensions, conductor stranding, mass and electrical ratings for ROBUST 210 / 215C per VDE 0250 / EN 50525 / ECOLAB Food & Beverage Washdown Control Specification.
| Order designation | Cross-section / size | Conductor build | Wall ≈ mm | Outer Ø ≈ mm | Metal kg/km | Weight ≈ kg/km | Min. bend R fixed mm | Enquiry |
|---|---|---|---|---|---|---|---|---|
| Standard ROBUST 210 / 215C configurations | ||||||||
| ROBUST 210 / 215C 3G0.5 | 3G0.5 mm² | Class 5 Cu (0.5 mm²) | 0.90 | 5.80 | 14.4 | 50.7 | 87 | |
| ROBUST 210 / 215C 4G0.5 | 4G0.5 mm² | Class 5 Cu (0.5 mm²) | 0.90 | 6.30 | 19.2 | 62.1 | 94 | |
| ROBUST 210 / 215C 5G0.5 | 5G0.5 mm² | Class 5 Cu (0.5 mm²) | 0.90 | 6.80 | 24.0 | 73.9 | 102 | |
| ROBUST 210 / 215C 7G0.5 | 7G0.5 mm² | Class 5 Cu (0.5 mm²) | 0.90 | 7.30 | 33.6 | 91.2 | 110 | |
| ROBUST 210 / 215C 12G0.5 | 12G0.5 mm² | Class 5 Cu (0.5 mm²) | 1.10 | 9.90 | 57.6 | 163.5 | 148 | |
| ROBUST 210 / 215C 3G0.75 | 3G0.75 mm² | Class 5 Cu (0.75 mm²) | 0.90 | 6.20 | 21.6 | 63.1 | 93 | |
| ROBUST 210 / 215C 4G0.75 | 4G0.75 mm² | Class 5 Cu (0.75 mm²) | 0.90 | 6.80 | 28.8 | 78.7 | 102 | |
| ROBUST 210 / 215C 5G0.75 | 5G0.75 mm² | Class 5 Cu (0.75 mm²) | 0.90 | 7.30 | 36.0 | 93.6 | 110 | |
| ROBUST 210 / 215C 7G0.75 | 7G0.75 mm² | Class 5 Cu (0.75 mm²) | 0.90 | 8.00 | 50.4 | 119.5 | 120 | |
| ROBUST 210 / 215C 12G0.75 | 12G0.75 mm² | Class 5 Cu (0.75 mm²) | 1.10 | 10.70 | 86.4 | 210.0 | 160 | |
| ROBUST 210 / 215C 18G0.75 | 18G0.75 mm² | Class 5 Cu (0.75 mm²) | 1.10 | 12.50 | 129.6 | 298.4 | 188 | |
| ROBUST 210 / 215C 3G1 | 3G1 mm² | Class 5 Cu (1 mm²) | 0.90 | 6.60 | 28.8 | 75.8 | 99 | |
| ROBUST 210 / 215C 4G1 | 4G1 mm² | Class 5 Cu (1 mm²) | 0.90 | 7.20 | 38.4 | 94.4 | 108 | |
| ROBUST 210 / 215C 5G1 | 5G1 mm² | Class 5 Cu (1 mm²) | 0.90 | 7.80 | 48.0 | 113.7 | 117 | |
| ROBUST 210 / 215C 7G1 | 7G1 mm² | Class 5 Cu (1 mm²) | 0.90 | 8.50 | 67.2 | 145.2 | 128 | |
| ROBUST 210 / 215C 12G1 | 12G1 mm² | Class 5 Cu (1 mm²) | 1.10 | 11.50 | 115.2 | 258.0 | 172 | |
| ROBUST 210 / 215C 18G1 | 18G1 mm² | Class 5 Cu (1 mm²) | 1.10 | 13.40 | 172.8 | 366.7 | 201 | |
| ROBUST 210 / 215C 3G1.5 | 3G1.5 mm² | Class 5 Cu (1.5 mm²) | 0.90 | 7.70 | 43.2 | 107.2 | 116 | |
| ROBUST 210 / 215C 4G1.5 | 4G1.5 mm² | Class 5 Cu (1.5 mm²) | 0.90 | 8.40 | 57.6 | 133.8 | 126 | |
| ROBUST 210 / 215C 5G1.5 | 5G1.5 mm² | Class 5 Cu (1.5 mm²) | 0.90 | 9.20 | 72.0 | 163.4 | 138 | |
| ROBUST 210 / 215C 7G1.5 | 7G1.5 mm² | Class 5 Cu (1.5 mm²) | 0.90 | 10.00 | 100.8 | 208.8 | 150 | |
| ROBUST 210 / 215C 12G1.5 | 12G1.5 mm² | Class 5 Cu (1.5 mm²) | 1.10 | 13.60 | 172.8 | 372.6 | 204 | |
| ROBUST 210 / 215C 18G1.5 | 18G1.5 mm² | Class 5 Cu (1.5 mm²) | 1.10 | 15.90 | 259.2 | 532.2 | 238 | |
| ROBUST 210 / 215C 25G1.5 | 25G1.5 mm² | Class 5 Cu (1.5 mm²) | 1.10 | 18.60 | 360.0 | 733.6 | 279 | |
| ROBUST 210 / 215C 3G2.5 | 3G2.5 mm² | Class 5 Cu (2.5 mm²) | 0.90 | 8.70 | 72.0 | 153.7 | 130 | |
| ROBUST 210 / 215C 4G2.5 | 4G2.5 mm² | Class 5 Cu (2.5 mm²) | 0.90 | 9.60 | 96.0 | 195.5 | 144 | |
| ROBUST 210 / 215C 5G2.5 | 5G2.5 mm² | Class 5 Cu (2.5 mm²) | 0.90 | 10.50 | 120.0 | 239.1 | 158 | |
| ROBUST 210 / 215C 7G2.5 | 7G2.5 mm² | Class 5 Cu (2.5 mm²) | 0.90 | 11.40 | 168.0 | 308.4 | 171 | |
| ROBUST 210 / 215C 4G4 | 4G4 mm² | Class 5 Cu (4 mm²) | 0.90 | 11.90 | 153.6 | 306.5 | 178 | |
| Configuration | Max. DC R @ 20 °C Ω/km | Primary rating (A or nF/km) | Secondary rating | Dielectric test V AC rms |
|---|---|---|---|---|
| 3G0.5 mm² | 39.00 | 9.0 | 7.0 | 4,000 |
| 4G0.5 mm² | 39.00 | 9.0 | 7.0 | 4,000 |
| 5G0.5 mm² | 39.00 | 9.0 | 7.0 | 4,000 |
| 7G0.5 mm² | 39.00 | 9.0 | 7.0 | 4,000 |
| 12G0.5 mm² | 39.00 | 9.0 | 7.0 | 4,000 |
| 3G0.75 mm² | 26.00 | 12.0 | 9.0 | 4,000 |
| 4G0.75 mm² | 26.00 | 12.0 | 9.0 | 4,000 |
| 5G0.75 mm² | 26.00 | 12.0 | 9.0 | 4,000 |
| 7G0.75 mm² | 26.00 | 12.0 | 9.0 | 4,000 |
| 12G0.75 mm² | 26.00 | 12.0 | 9.0 | 4,000 |
| 18G0.75 mm² | 26.00 | 12.0 | 9.0 | 4,000 |
| 3G1 mm² | 19.50 | 15.0 | 11.0 | 4,000 |
| 4G1 mm² | 19.50 | 15.0 | 11.0 | 4,000 |
| 5G1 mm² | 19.50 | 15.0 | 11.0 | 4,000 |
| 7G1 mm² | 19.50 | 15.0 | 11.0 | 4,000 |
| 12G1 mm² | 19.50 | 15.0 | 11.0 | 4,000 |
| 18G1 mm² | 19.50 | 15.0 | 11.0 | 4,000 |
| 3G1.5 mm² | 13.30 | 18.0 | 14.0 | 4,000 |
| 4G1.5 mm² | 13.30 | 18.0 | 14.0 | 4,000 |
| 5G1.5 mm² | 13.30 | 18.0 | 14.0 | 4,000 |
| 7G1.5 mm² | 13.30 | 18.0 | 14.0 | 4,000 |
| 12G1.5 mm² | 13.30 | 18.0 | 14.0 | 4,000 |
| 18G1.5 mm² | 13.30 | 18.0 | 14.0 | 4,000 |
| 25G1.5 mm² | 13.30 | 18.0 | 14.0 | 4,000 |
| 3G2.5 mm² | 7.98 | 26.0 | 20.0 | 4,000 |
| 4G2.5 mm² | 7.98 | 26.0 | 20.0 | 4,000 |
| 5G2.5 mm² | 7.98 | 26.0 | 20.0 | 4,000 |
| 7G2.5 mm² | 7.98 | 26.0 | 20.0 | 4,000 |
| 4G4 mm² | 4.95 | 34.0 | 26.0 | 4,000 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Dielectric spark / high-voltage withstand test | 100 % in-line spark and AC/DC dielectric withstand per VDE 0250 / EN 50525 / ECOLAB Food & Beverage Washdown Control Specification | Every manufactured length |
| Conductor DC resistance & continuity check | Within maximum 20 °C resistance limit specified for ROBUST 210 / 215C | Every spool or drum length |
| Sample tests | ||
| Insulation resistance & dimensional verification | Wall thickness, concentricity and insulation resistance per VDE 0250 / EN 50525 / ECOLAB Food & Beverage Washdown Control Specification | Per production batch |
| Environmental, mechanical & EMC qualification | Qualified to VDE 0250 / EN 50525 / ECOLAB Food & Beverage Washdown Control Specification thermal, mechanical and environmental performance criteria | Type qualification |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.