Product
TP-TDL & TDS 600 V – 2,000 V IEEE 1580 Type P Offshore Rig Top Drive Service Loop Composite Cable (IEEE 1580 Type P / ABS-DNV) engineered for 600 V – 2,000 V service across -40 to +125 °C (min. bend radius 8 × OD).
Typical values for this cable type, based on IEEE 1580 Type P & ABS/DNV Drilling Derrick Top Drive Service Loop — confirmed in the datasheet and quotation for your order.
Application fit
TP-TDL & TDS 600 V – 2,000 V IEEE 1580 Type P Offshore Rig Top Drive Service Loop Composite Cable (IEEE 1580 Type P / ABS-DNV) engineered for 600 V – 2,000 V service across -40 to +125 °C (min. bend radius 8 × OD).
IEC/IEEE 80005-1 compliant HVSC electro-optical design supplies clean berth power with integrated pilot and fibre cores.
Integrated anti-torsion braid and flexible Class 5 conductors withstand continuous motorized reeling and tensioning.
Top-drive service loop execution handles continuous vertical flexing, torsion and ester drilling mud splash in the derrick.
Heavy-duty polychloroprene / CSP / Type P outer sheath resists seawater immersion, quayside abrasion, oil and UV.
Heavy shore-power and derrick reeling cable is not intended for small-radius indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: TP-TDL & TDS (TOP DRIVE LOOP) (IEEE 1580 Type P & ABS/DNV Drilling Derrick Top Drive Service Loop) featuring extra-flex top drive power cores (2000 v), screened encoder & control sub-units and heavy-duty mud-resistant service loop jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Extra-Flex Top Drive Power Cores (2000 V | Ultra-flexible stranded tinned copper with 125 °C XLPO insulation |
| 2 | Screened Encoder & Control Sub-Units | Tinned-copper-braid shielded pairs in outer interstices |
| 3 | Anti-Torsion Dynamic Core Bedding | Low-friction elastomeric filler engineered for vertical derrick flexing |
| 4 | Tinned Copper / Aramid Reinforcement Bra | High-coverage braid absorbing dynamic suspension and torsional loads |
| 5 | Heavy-Duty Mud-Resistant Service Loop Ja | High-visibility yellow ester-mud and abrasion-resistant elastomer sheath |
Built to IEEE 1580 Type P & ABS/DNV Drilling Derrick Top Drive Service Loop with extra-flex top drive power cores (2000 v) and heavy-duty mud-resistant service loop jacket
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEEE 1580 Type P & ABS/DNV Drilling Derrick Top Drive Service Loop for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| TP-TDL & TDS (TOP DRIVE LOOP) Construction Schedule (−40…+125 °C) | |||||||
| TP-TDL & TDS 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| TP-TDL & TDS 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| TP-TDL & TDS 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 600 V – 2,000 V (98 A) | −40…+125 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 600 V – 2,000 V (158 A) | −40…+125 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 600 V – 2,000 V (245 A) | −40…+125 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEEE 1580 Type P & ABS/DNV Drilling Derrick Top Drive Service Loop) | DC resistance at 20 °C / optical attenuation and outer diameter within IEEE 1580 Type P & ABS/DNV Drilling Derrick Top Drive Service Loop tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEEE 1580 Type P & ABS/DNV Drilling Derrick Top Drive Service Loop) | Zero dielectric breakdown and verified insulation resistance for 600 V – 2,000 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEEE 1580 Type P & ABS/DNV Drilling Derrick Top Drive Service Loop) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+125 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.