Fixed installation
High-density multi-core construction routes compactly through marine cable trays, bulkheads and equipment racks.
Product
TPD, TPD-CW/SB & C14PNBS 600 V (0.6/1 kV) IEEE 1580 Type P Braided Offshore Rig Control & Power Cable (IEEE 1580 Type P / UL 1309) engineered for 0.6/1 kV service across -40 to +125 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 (125 °C XLPO) — confirmed in the datasheet and quotation for your order.
Application fit
TPD, TPD-CW/SB & C14PNBS 600 V (0.6/1 kV) IEEE 1580 Type P Braided Offshore Rig Control & Power Cable (IEEE 1580 Type P / UL 1309) engineered for 0.6/1 kV service across -40 to +125 °C (min. bend radius 6 × OD).
High-density multi-core construction routes compactly through marine cable trays, bulkheads and equipment racks.
Number-coded or colour-coded cores simplify termination inside marine switchgear, bridge consoles and control panels.
Cross-linked LFH/SHF1/Type P jacket resists marine oils, lubricants, moisture and mechanical abrasion.
High-coverage copper or bronze braid provides both mechanical protection and 360° EMC screening.
Fixed shipboard and naval control cable is not intended for vertical deepwater lift winches.
Use A304739 BOP MUX UmbilicalConstruction
Shown: TPD & TPD-CW/SB / C14PNBS (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 (125 °C XLPO)) featuring flexible tinned copper (12c × 14 awg), 125 °c xlpo type p core insulation and arctic type n mud-resistant jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Tinned Copper (12C × 14 AWG) | Finely stranded tinned copper conductors (IEEE 1580 / ASTM B33) |
| 2 | 125 °C XLPO Type P Core Insulation | Irradiated cross-linked polyolefin with ICEA Method 1/4 identification |
| 3 | Thermoset Inner Jacket (PN) | Extruded flame- and oil-resistant elastomeric inner bedding |
| 4 | Bronze Wire Braid Armour (SB / BS) | High-coverage bronze wire braid mechanical armour |
| 5 | Arctic Type N Mud-Resistant Jacket | Heavy-duty thermoset outer sheath rated -40 °C to +110 °C |
Built to IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 (125 °C XLPO) with flexible tinned copper (12c × 14 awg) and arctic type n mud-resistant jacket
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 (125 °C XLPO) for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| TPD & TPD-CW/SB / C14PNBS Construction Schedule (−40…+125 °C) | |||||||
| TPD 4G2.5 mm² | 4 × 2.5 mm² (or 4C × 14 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 13.2 | 275 | 1.5 | 80 | |
| TPD 7G2.5 mm² | 7 × 2.5 mm² (or 7C × 14 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 15.8 | 415 | 2.6 | 95 | |
| TPD 12G1.5 mm² | 12 × 1.5 mm² (or 12C × 16 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 17.4 | 495 | 2.7 | 105 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × 2.5 mm² (or 4C × 14 AWG) | 7.98 | 0.6/1 kV (26 A) | −40…+125 °C |
| 7 × 2.5 mm² (or 7C × 14 AWG) | 7.98 | 0.6/1 kV (21 A) | −40…+125 °C |
| 12 × 1.5 mm² (or 12C × 16 AWG) | 13.30 | 0.6/1 kV (14 A) | −40…+125 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 (125 °C XLPO)) | DC resistance at 20 °C / optical attenuation and outer diameter within IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 (125 °C XLPO) tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 (125 °C XLPO)) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 (125 °C XLPO)) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+125 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.