Instalación fija
Engineered y verified para fixed service in accordance con IEC 60584-3 / DIN VDE 0285.
Producto
Type JX Thermocouple Extension + 5G1.5 Control Composite cable (TC-JX Hybrid (2×2×0.5 JX + 5G1.5)) diseñado según IEC 60584-3 / DIN VDE 0285 para 300/500 V servicio en -30 °C a +90 °C, con cableado iron / cobre nickel / cobre conductor y pvc outer
Valores típicos para este tipo de cable, basados en IEC 60584-3 / DIN VDE 0285 — confirmados en la ficha técnica y oferta de su pedido.
Aplicaciones
Type JX Thermocouple Extension + 5G1.5 Control Composite cable (TC-JX Hybrid (2×2×0.5 JX + 5G1.5)) diseñado según IEC 60584-3 / DIN VDE 0285 para 300/500 V servicio en -30 °C a +90 °C, con cableado iron / cobre nickel / cobre conductor y pvc outer
Engineered y verified para fixed service in accordance con IEC 60584-3 / DIN VDE 0285.
Engineered y verified para furnace kiln service in accordance con IEC 60584-3 / DIN VDE 0285.
Suitable para switchgear, control panels y equipment terminations within 7.5 × OD bend radius.
Use mechanical conduit o armado protection where exposed a rock fall o crushing loads.
Construcción
Shown: TC-JX Hybrid (2×2×0.5 JX + 5G1.5) (IEC 60584-3 / DIN VDE 0285) con cableado iron / cobre nickel / cobre conductor, thermocouple element cobre estañado trenza y pvc cubierta exterior (5-layer construcción).
| # | Capa | Material y referencia |
|---|---|---|
| 1 | cableado iron / cobre nickel / cobre conductor | High-conductivity iron / cobre nickel / cobre conductor per IEC 60584-3 / DIN VDE 0285IEC 60584-3 / DIN VDE 0285 |
| 2 | Thermocouple element cobre estañado trenza | Thermocouple element cobre estañado trenza high-coverage braided layer (individual core / group layer)IEC 60584-3 / DIN VDE 0285 |
| 3 | PVC Aislamiento de conductor | Extruded PVC dielectric (individual core / group layer)IEC 60584-3 / DIN VDE 0285 |
| 4 | Wrapping y banding | Helically applied wrapping y bandingIEC 60584-3 / DIN VDE 0285 |
| 5 | PVC cubierta exterior | Extruded PVC cubierta exterior protective layer (continuous layer)IEC 60584-3 / DIN VDE 0285 |
Built a IEC 60584-3 / DIN VDE 0285 con cableado iron / cobre nickel / cobre conductor y pvc cubierta exterior
Full range of metric mm² y AWG/kcmil conductor sizes per IEC 60584-3 / DIN VDE 0285
Supplied con EN 10204 3.1 routine dielectric & conductor resistance test certificate
Datos técnicos
Dimensiones
Manufactured a IEC 60584-3 / DIN VDE 0285 in single-pair, multi-pair y multi-unit constructions.
| Designación de pedido | Configuración | Ø exterior ≈ mm | Peso ≈ kg/km | Min. curvatura R fijo mm | Consulta |
|---|---|---|---|---|---|
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) Standard construcción Schedule (300/500 V · −30…+90 °C) | |||||
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 1×2×0.5 | 1×2×0.5 mm² | 6.4 | 58 | 52 | |
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 2×2×0.5 | 2×2×0.5 mm² | 9.2 | 112 | 74 | |
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 4×2×0.5 | 4×2×0.5 mm² | 11.4 | 176 | 92 | |
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 8×2×0.5 | 8×2×0.5 mm² | 14.8 | 295 | 118 | |
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 12×2×0.5 | 12×2×0.5 mm² | 17.6 | 420 | 141 | |
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 1×2×1.0 | 1×2×1.0 mm² | 7.6 | 86 | 61 | |
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 2×2×1.0 | 2×2×1.0 mm² | 11.0 | 168 | 88 | |
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 4×2×1.0 | 4×2×1.0 mm² | 13.5 | 264 | 108 | |
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 8×2×1.0 | 8×2×1.0 mm² | 17.9 | 465 | 143 | |
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 1×2×1.5 | 1×2×1.5 mm² | 8.5 | 114 | 68 | |
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 4×2×1.5 | 4×2×1.5 mm² | 15.2 | 348 | 122 | |
| TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 12×2×1.5 | 12×2×1.5 mm² | 23.4 | 860 | 187 | |
| Sección del conductor | R₂₀ CC máx. Ω/km | Cap. mutua ≈ nF/km | Inductancia ≈ mH/km |
|---|---|---|---|
| 0.50 mm² (7/0.30 mm · AWG 20) | 39.00 | 115 | 0.65 |
| 0.75 mm² (7/0.37 mm · AWG 18) | 26.00 | 120 | 0.62 |
| 1.00 mm² (7/0.43 mm · AWG 17) | 19.50 | 125 | 0.60 |
| 1.50 mm² (7/0.53 mm · AWG 16) | 13.30 | 135 | 0.58 |
| 2.50 mm² (7/0.67 mm · AWG 14) | 7.98 | 145 | 0.55 |
Calidad y homologaciones
Ensayos de rutina en cada longitud de fabricación, ensayos de muestreo y tipo por lote — documentados en un certificado EN 10204 3.1.
| Ensayos e inspección | Valor de ensayo / referencia | Frecuencia |
|---|---|---|
| Ensayos de rutina | ||
| conductor DC resistance & dimensional verification (IEC 60584-3 / DIN VDE 0285) | DC resistance at 20 °C y geometry within IEC 60584-3 / DIN VDE 0285 class limits | Every manufactured drum / spool |
| Routine dielectric / spark / structural integrity test (IEC 60584-3 / DIN VDE 0285) | Zero breakdown o structural defect over full production length | Every manufactured drum / spool |
| Ensayos por muestreo | ||
| Thermal aging, mechanical & material qualification (IEC 60584-3 / DIN VDE 0285) | Full compliance con IEC 60584-3 / DIN VDE 0285 across −30…+90 °C | Type qualification & periodic sample audit |
Marcado y suministro
Marcado de la cubierta
Documentación técnica
Preguntas frecuentes
¿No está aquí? Envíenos su plano — un ingeniero responde en 2 horas laborables.
Solicitar presupuesto
La selección y los datos de aplicación se copian al formulario de consulta inferior.
Use + Añadir junto a una medida o configuración.