Immersion & wet locations
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Product
0.6/1 kV Subsea Caisson Pump Power & Screened Sensor Data Steel-Braid Armoured Composite Cable (1,500 m) (Subsea Caisson Pump / 0.6/1 kV) engineered for 0.6/1 kV service across -30 to +90 °C (min. bend radius 8 × OD).
Typical values for this cable type, based on 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification — confirmed in the datasheet and quotation for your order.
Application fit
0.6/1 kV Subsea Caisson Pump Power & Screened Sensor Data Steel-Braid Armoured Composite Cable (1,500 m) (Subsea Caisson Pump / 0.6/1 kV) engineered for 0.6/1 kV service across -30 to +90 °C (min. bend radius 8 × OD).
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling
Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.
UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.
Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.
Use M23 Servo AssemblyConstruction
Shown: Subsea Caisson Cable (0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification) featuring caisson pump power conductors (4 cores), shielded sensor data twisted pairs (4×2) and flame-retardant heavy pur outer jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Caisson Pump Power Conductors (4 Cores) | Stranded tinned copper conductors with water-resistant XLPO insulation |
| 2 | Shielded Sensor Data Twisted Pairs (4×2) | Individually foil-screened pairs for caisson level, vibration & temp monitoring |
| 3 | PUR Inner Sheath & Galvanized Steel Brai | Waterproof PUR inner jacket + galvanized steel wire braid armour |
| 4 | Flame-Retardant Heavy PUR Outer Jacket | High-strength flame-retardant polyurethane outer sheath |
Built to 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification with caisson pump power conductors (4 cores) and flame-retardant heavy pur outer jacket
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Subsea Caisson Cable Construction Schedule (−30…+90 °C) | |||||||
| Subsea Caisson Cable 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (or 1C×50 mm²) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 18.5 | 135 | |
| Subsea Caisson Cable 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (or 1C×150 mm²) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 32.0 | 175 | |
| Subsea Caisson Cable 3×95+1G50 mm² | 3 × 95 + 1G50 mm² (or 1C×300 mm²) | IEC 60228 Class 2/5 Cu/SnCu | 41.2 | 3,680 | 58.0 | 250 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (or 1C×50 mm²) | 1.15 | 0.6/1 kV (98 A) | −30…+90 °C |
| 3 × 35 + 1G16 mm² (or 1C×150 mm²) | 0.52 | 0.6/1 kV (158 A) | −30…+90 °C |
| 3 × 95 + 1G50 mm² (or 1C×300 mm²) | 0.19 | 0.6/1 kV (285 A) | −30…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −30…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.