Contact
subsea umbilical, ROV tether & oceanographic tow cableSubsea Caisson Pump / 0.6/1 kV0.6/1 kV (-30 to +90 °C)Flame-Retardant Heavy PUR Outer Jack

0.6/1 kV Subsea Caisson Pump Power & Screened Sensor Data Steel-Braid Armoured Composite Cable (1,500 m)Subsea Caisson Pump / 0.6/1 kV — 0.6/1 kV — -30 to +90 °C Subsea & Offshore Cable

0.6/1 kV Subsea Caisson Pump Power & Screened Sensor Data Steel-Braid Armoured Composite Cable (1,500 m) (Subsea Caisson Pump / 0.6/1 kV) engineered for 0.6/1 kV service across -30 to +90 °C (min. bend radius 8 × OD).

Water-resistant
EMC screen
Oil-resistant
Approved
Order designation
Subsea Caisson Cable 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
18.5 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per Subsea Caisson Pump / 0.6/1 k
Operating temp.
−30…+90 °C
Continuous subsea & offshore service
Min. bend radius
8 × OD
Winch sheave, chute & seabed routing
Core / conductor
Caisson Pump Pow
Stranded tinned copper conductors with w
Outer protection
Flame-Retardant
High-strength flame-retardant polyuretha
Standard
Subsea Caisson P
0.6/1 kV Subsea Caisson Pump Power + Scr

Typical values for this cable type, based on 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is Subsea Caisson Cable right for your machine?

0.6/1 kV Subsea Caisson Pump Power & Screened Sensor Data Steel-Braid Armoured Composite Cable (1,500 m) (Subsea Caisson Pump / 0.6/1 kV) engineered for 0.6/1 kV service across -30 to +90 °C (min. bend radius 8 × OD).

Immersion & wet locations

Suitable

Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.

Vertical / spreader reel

Suitable

Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling

Trailing & towing

Suitable

Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.

Offshore platform & shipboard deck trays

Suitable

UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.

Energy chain / drag chain

Not suitable

Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.

Use M23 Servo Assembly
Typical machinesMarine & Offshore CableOceanographic CTD, ADCP & Deep-Tow SurveysWork-Class & Observation ROV / AUV SystemsSide-Scan Sonar, SAS & Towed Hydrophone ArraysMarine 2D/3D/UHR Seismic Streamers & OBC

Construction

Layer by layer

Shown: Subsea Caisson Cable (0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification) featuring caisson pump power conductors (4 cores), shielded sensor data twisted pairs (4×2) and flame-retardant heavy pur outer jacket (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Caisson Pump Power Conductors (4 Cores)Stranded tinned copper conductors with water-resistant XLPO insulation
2Shielded Sensor Data Twisted Pairs (4×2)Individually foil-screened pairs for caisson level, vibration & temp monitoring
3PUR Inner Sheath & Galvanized Steel BraiWaterproof PUR inner jacket + galvanized steel wire braid armour
4Flame-Retardant Heavy PUR Outer JacketHigh-strength flame-retardant polyurethane outer sheath

Subsea Caisson Cable — Standard Subsea & Offshore Execution

Built to 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification with caisson pump power conductors (4 cores) and flame-retardant heavy pur outer jacket

Subsea Caisson Cable — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

Subsea Caisson Cable — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification)
Core / conductor construction
Caisson Pump Power Conductors (4 Cores) — Stranded tinned copper conductors with water-resistant XLPO insulation
Primary dielectric / buffering
Shielded Sensor Data Twisted Pairs (4×2) — Individually foil-screened pairs for caisson level, vibration & temp monitoring

Thermal

Continuous operating temperature
−30…+90 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
Flame-Retardant Heavy PUR Outer Jacket — High-strength flame-retardant polyurethane outer sheath
Minimum bending radius
8 × OD
Armour, strength member & mechanical duty
PUR Inner Sheath & Galvanized Steel Braid — Waterproof PUR inner jacket + galvanized steel wire braid armour

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
Subsea Caisson Cable
Sheath colour & metre marking
Continuous metre-marked black outer finish (Flame-Retardant )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard Subsea Caisson Cable subsea & offshore configurations

Manufactured to 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
Subsea Caisson Cable Construction Schedule (−30…+90 °C)
Subsea Caisson Cable 3×16+1G16 mm²3 × 16 + 1G16 mm² (or 1C×50 mm²)IEC 60228 Class 2/5 Cu/SnCu22.492018.5135
Subsea Caisson Cable 3×35+1G16 mm²3 × 35 + 1G16 mm² (or 1C×150 mm²)IEC 60228 Class 2/5 Cu/SnCu28.81,69032.0175
Subsea Caisson Cable 3×95+1G50 mm²3 × 95 + 1G50 mm² (or 1C×300 mm²)IEC 60228 Class 2/5 Cu/SnCu41.23,68058.0250
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification)DC resistance at 20 °C / optical attenuation and outer diameter within 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −30…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

Subsea Caisson Pump / 0.6/1 kV CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX Subsea Caisson Cable Subsea Caisson Pump / 0.6/1 kV 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define Subsea Caisson Cable (0.6/1 kV Subsea Caisson Pump Power & Screened Sensor Data Steel-Braid Armoured Composite Cable (1,500 m))?
Subsea Caisson Cable (0.6/1 kV Subsea Caisson Pump Power & Screened Sensor Data Steel-Braid Armoured Composite Cable (1,500 m)) is manufactured in accordance with 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification for 0.6/1 kV service over -30 to +90 °C. Its 4-layer construction comprises caisson pump power conductors (4 cores), shielded sensor data twisted pairs (4×2) and flame-retardant heavy pur outer jacket.
What is the minimum bending radius and operating temperature range for Subsea Caisson Cable?
The minimum bending radius for Subsea Caisson Cable is 8 × OD across its continuous operating temperature range of -30 to +90 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of Subsea Caisson Cable arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Caisson Pump Power Conductors (4 Cores) — Stranded tinned copper conductors with water-resistant XLPO insulation; (02) Shielded Sensor Data Twisted Pairs (4×2) — Individually foil-screened pairs for caisson level, vibration & temp monitoring; (03) PUR Inner Sheath & Galvanized Steel Braid — Waterproof PUR inner jacket + galvanized steel wire braid armour; (04) Flame-Retardant Heavy PUR Outer Jacket — High-strength flame-retardant polyurethane outer sheath.
What factory test certificates are supplied with Subsea Caisson Cable?
Every production drum of Subsea Caisson Cable undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per 0.6/1 kV Subsea Caisson Pump Power + Screened Data Pairs Steel-Braid Armoured PUR Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for Subsea Caisson Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

0.6/1 kV Subsea Caisson Pump Power & Screened Sensor Data Steel-Braid Armoured Composite Cable (1,500 m)

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote