Immersion & wet locations
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Product
600–3,300 V Subsea Electro-Optical ROV, Diving Bell & Seabed Node Umbilical Tether featuring sm/mm optical fiber unit and polyurethane (pur / tpe-e) outer jacket (ISO 13628-5 / Subsea EO Umbilical, 600 V – 3,300 V, -30 to +80 °C).
Typical values for this cable type, based on Subsea Electro-Optical ROV, Diving Bell & Node Interconnect Umbilical Specification — confirmed in the datasheet and quotation for your order.
Application fit
600–3,300 V Subsea Electro-Optical ROV, Diving Bell & Seabed Node Umbilical Tether featuring sm/mm optical fiber unit and polyurethane (pur / tpe-e) outer jacket (ISO 13628-5 / Subsea EO Umbilical, 600 V – 3,300 V, -30 to +80 °C).
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling
Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.
UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.
Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.
Use M23 Servo AssemblyConstruction
Shown: Subsea EO Umbilical (Subsea Electro-Optical ROV, Diving Bell & Node Interconnect Umbilical Specification) featuring sm/mm optical fiber unit, power cores & shielded signal pairs and polyurethane (pur / tpe-e) outer jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | SM/MM Optical Fiber Unit | Central pressure-resistant tube with single-mode and multi-mode fibers |
| 2 | Power Cores & Shielded Signal Pairs | Tinned/silver-plated copper cores with XLPE/PE/FEP insulation |
| 3 | Aramid / Steel Braid Reinforcement | High-tensile braided strength member over TPE inner sheath |
| 4 | Polyurethane (PUR / TPE-E) Outer Jacket | High-visibility orange hydrolysis- and abrasion-resistant sheath |
Built to Subsea Electro-Optical ROV, Diving Bell & Node Interconnect Umbilical Specification with sm/mm optical fiber unit and polyurethane (pur / tpe-e) outer jacket
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to Subsea Electro-Optical ROV, Diving Bell & Node Interconnect Umbilical Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Subsea EO Umbilical Construction Schedule (−30…+80 °C) | |||||||
| Subsea EO Umbilical Config A | 3×25–50 mm² (or 3P+FO Composite) | Compacted / Class 5 Cu/SnCu + FO | 32.0 | 1,850 | 85.0 | 380 | |
| Subsea EO Umbilical Config B | 3×95–150 mm² (or Heavy EOM) | Compacted / Class 5 Cu/SnCu + FO | 48.5 | 4,280 | 130.0 | 580 | |
| Subsea EO Umbilical Config C | 3×240–400 mm² (or Trunk HV/MV) | Compacted Cu + Lead/Armour + FO | 78.0 | 9,650 | 210.0 | 950 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3×25–50 mm² (or 3P+FO Composite) | 0.50 | 600 V – 3,300 V (Subsea/MV) | −30…+80 °C |
| 3×95–150 mm² (or Heavy EOM) | 0.19 | 600 V – 3,300 V (Subsea/MV) | −30…+80 °C |
| 3×240–400 mm² (or Trunk HV/MV) | 0.08 | 600 V – 3,300 V (Trunk/HV) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (Subsea Electro-Optical ROV, Diving Bell & Node Interconnect Umbilical Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within Subsea Electro-Optical ROV, Diving Bell & Node Interconnect Umbilical Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (Subsea Electro-Optical ROV, Diving Bell & Node Interconnect Umbilical Specification) | Zero dielectric breakdown and verified insulation resistance for 600 V – 3,300 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (Subsea Electro-Optical ROV, Diving Bell & Node Interconnect Umbilical Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.