Contact
15 kV DC repeatered transoceanic submarine optical telecom cableITU-T G.978 / UJC SL1715,000 V DC (1.00 Ω/km)24-Wire Pressure Vault

SL17 (SL17-LW / SL17-LWA / SL17-DA) 15 kV DC Undersea Telecom CableITU-T G.978 / UJC SL17 · 12/20 kV · 15 kv dc repeatered transoceanic submarine optical

SL17 (SL17-LW / SL17-LWA / SL17-DA) 15 kV DC Undersea Telecom Cable (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17) engineered for 12/20 kV service across -10 °C to +60 °C (min. bend radius 20 × OD).

Water-resistant
EMC screen
Outdoor & humid
Approved
Order designation
SL17 4F Single-Mode OS2
Outer Ø ≈
3.5 mm
Net weight ≈
18 kg/km
Tensile rating ≈
3.4 kN
Core / stranding
Hermetic / gel-filled optical core
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
12/20 kV
Tested per ITU-T G.978 / UJC SL17
Operating temp.
−10…+60 °C
Continuous subsea & marine service
Min. bend radius
20 × OD
Dynamic sheave & fixed routing
Core / conductor
8–24 SM Pairs
Unit Fiber Structure in 24-wire steel
Outer protection
LW HDPE
18ר3.35 mm galvanized SWA
Standard
ITU-T G.978
ITU-T G.978

Typical values for this cable type, based on ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17 — confirmed in the datasheet and quotation for your order.

Application fit

Is SL17 (SL17-LW / SL17-LWA / SL17-DA) right for your machine?

SL17 (SL17-LW / SL17-LWA / SL17-DA) 15 kV DC Undersea Telecom Cable (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17) engineered for 12/20 kV service across -10 °C to +60 °C (min. bend radius 20 × OD).

Immersion & wet locations

Suitable

Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.

Vertical / spreader reel

Suitable

Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.

Offshore platform & shipboard deck trays

Suitable

Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.

Trailing & towing

Suitable

High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.

Energy chain / drag chain

Not suitable

Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableWork-Class & Observation ROV SystemsOffshore Wind & Subsea Power GridsOceanographic, Sonar & Seismic SurveyCommercial Diving & Subsea Intervention

Construction

Layer by layer

Shown: SL17 (SL17-LW / SL17-LWA / SL17-DA) (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17) featuring unit fiber structure (ufs), 24-wire dual-layer steel pressure vault and galvanized steel armour & tar nylon yarn (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Unit Fiber Structure (UFS)Extruded PBT loose tube filled with thixotropic gel housing 8–24 SM fiber pairs
224-Wire Dual-Layer Steel Pressure VaultInner 8ר1.59 mm + outer 16 alternating (Ø1.50/1.13 mm) wires + hydrophobic fill
3Seam-Welded Copper Sheath (15 kV DC)Continuously welded copper tube (1.00 Ω/km @ 3 °C) providing radial H₂ barrier
4EAA Co-Extrusion & MDPE/HDPE JacketBonded high-voltage polyethylene insulation forming the Ø 17.0 mm SL17-LW core
5Galvanized Steel Armour & Tar Nylon Yarn18ר3.35 mm armour wires (SL17-LWA, +24 on DA) + 2 layers tar-impregnated nylon

SL17 (SL17-LW / SL17-LWA / SL17-DA) — Standard Subsea & Marine Execution

Built to ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17 with unit fiber structure (ufs) and galvanized steel armour & tar nylon yarn

SL17 (SL17-LW / SL17-LWA / SL17-DA) — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

SL17 (SL17-LW / SL17-LWA / SL17-DA) — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
12/20 kV (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17)
Core / conductor construction
Unit Fiber Structure (UFS) — Extruded PBT loose tube filled with thixotropic gel housing 8–24 SM fiber pairs
Primary dielectric / buffering
24-Wire Dual-Layer Steel Pressure Vault — Inner 8ר1.59 mm + outer 16 alternating (Ø1.50/1.13 mm) wires + hydrophobic fill

Thermal

Continuous operating temperature
−10…+60 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Galvanized Steel Armour & Tar Nylon Yarn — 18ר3.35 mm armour wires (SL17-LWA, +24 on DA) + 2 layers tar-impregnated nylon
Minimum bending radius
20 × OD
Hydrostatic, tensile & crush duty
EAA Co-Extrusion & MDPE/HDPE Jacket — Bonded high-voltage polyethylene insulation forming the Ø 17.0 mm SL17-LW core

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
SL17 (SL17-LW / SL17-LWA / SL17-DA)
Sheath colour & metre marking
Continuous metre-marked black outer finish (LW HDPE / LWA & DA SWA)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard SL17 (SL17-LW / SL17-LWA / SL17-DA) subsea & marine configurations

Manufactured to ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17 for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
SL17 (SL17-LW / SL17-LWA / SL17-DA) Construction Schedule (−10…+60 °C)
SL17 4F Single-Mode OS24 × G.652.D / G.657.A2 SM (200 kpsi)Hermetic / gel-filled optical core3.5183.435
SL17 12F Single-Mode OS212 × G.652.D / G.657.A2 SM (200 kpsi)Hermetic / gel-filled optical core9.814518.098
SL17 24F Armoured Subsea24 × G.652.D SM + Strength ArmourSubsea pressure-resistant optical unit17.058095.0255
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17)DC resistance at 20 °C / optical attenuation and outer diameter within ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17)Zero dielectric breakdown and verified insulation resistance for 12/20 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17)Verified submersion integrity, tensile load and thermal stability across −10…+60 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ITU-T G.978 / UJC SL17 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX SL17 (SL17-LW / SL17-LWA / SL17-DA) ITU-T G.978 / UJC SL17 12/20 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define SL17 (SL17-LW / SL17-LWA / SL17-DA) (SL17 (SL17-LW / SL17-LWA / SL17-DA) 15 kV DC Undersea Telecom Cable)?
SL17 (SL17-LW / SL17-LWA / SL17-DA) (SL17 (SL17-LW / SL17-LWA / SL17-DA) 15 kV DC Undersea Telecom Cable) is manufactured in accordance with ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17 for 12/20 kV service over -10 °C to +60 °C. Its 5-layer construction comprises unit fiber structure (ufs), 24-wire dual-layer steel pressure vault and galvanized steel armour & tar nylon yarn.
What is the minimum bending radius and operating temperature range for SL17 (SL17-LW / SL17-LWA / SL17-DA)?
The minimum bending radius for SL17 (SL17-LW / SL17-LWA / SL17-DA) is 20 × OD across its continuous operating temperature range of -10 °C to +60 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of SL17 (SL17-LW / SL17-LWA / SL17-DA) arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Unit Fiber Structure (UFS) — Extruded PBT loose tube filled with thixotropic gel housing 8–24 SM fiber pairs; (02) 24-Wire Dual-Layer Steel Pressure Vault — Inner 8ר1.59 mm + outer 16 alternating (Ø1.50/1.13 mm) wires + hydrophobic fill; (03) Seam-Welded Copper Sheath (15 kV DC) — Continuously welded copper tube (1.00 Ω/km @ 3 °C) providing radial H₂ barrier; (04) EAA Co-Extrusion & MDPE/HDPE Jacket — Bonded high-voltage polyethylene insulation forming the Ø 17.0 mm SL17-LW core; (05) Galvanized Steel Armour & Tar Nylon Yarn — 18ר3.35 mm armour wires (SL17-LWA, +24 on DA) + 2 layers tar-impregnated nylon.
What factory test certificates are supplied with SL17 (SL17-LW / SL17-LWA / SL17-DA)?
Every production drum of SL17 (SL17-LW / SL17-LWA / SL17-DA) undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for SL17 (SL17-LW / SL17-LWA / SL17-DA)

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

SL17 (SL17-LW / SL17-LWA / SL17-DA) 15 kV DC Undersea Telecom Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote