Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
SL17 (SL17-LW / SL17-LWA / SL17-DA) 15 kV DC Undersea Telecom Cable (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17) engineered for 12/20 kV service across -10 °C to +60 °C (min. bend radius 20 × OD).
Typical values for this cable type, based on ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17 — confirmed in the datasheet and quotation for your order.
Application fit
SL17 (SL17-LW / SL17-LWA / SL17-DA) 15 kV DC Undersea Telecom Cable (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17) engineered for 12/20 kV service across -10 °C to +60 °C (min. bend radius 20 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: SL17 (SL17-LW / SL17-LWA / SL17-DA) (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17) featuring unit fiber structure (ufs), 24-wire dual-layer steel pressure vault and galvanized steel armour & tar nylon yarn (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Unit Fiber Structure (UFS) | Extruded PBT loose tube filled with thixotropic gel housing 8–24 SM fiber pairs |
| 2 | 24-Wire Dual-Layer Steel Pressure Vault | Inner 8ר1.59 mm + outer 16 alternating (Ø1.50/1.13 mm) wires + hydrophobic fill |
| 3 | Seam-Welded Copper Sheath (15 kV DC) | Continuously welded copper tube (1.00 Ω/km @ 3 °C) providing radial H₂ barrier |
| 4 | EAA Co-Extrusion & MDPE/HDPE Jacket | Bonded high-voltage polyethylene insulation forming the Ø 17.0 mm SL17-LW core |
| 5 | Galvanized Steel Armour & Tar Nylon Yarn | 18ר3.35 mm armour wires (SL17-LWA, +24 on DA) + 2 layers tar-impregnated nylon |
Built to ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17 with unit fiber structure (ufs) and galvanized steel armour & tar nylon yarn
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17 for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| SL17 (SL17-LW / SL17-LWA / SL17-DA) Construction Schedule (−10…+60 °C) | |||||||
| SL17 4F Single-Mode OS2 | 4 × G.652.D / G.657.A2 SM (200 kpsi) | Hermetic / gel-filled optical core | 3.5 | 18 | 3.4 | 35 | |
| SL17 12F Single-Mode OS2 | 12 × G.652.D / G.657.A2 SM (200 kpsi) | Hermetic / gel-filled optical core | 9.8 | 145 | 18.0 | 98 | |
| SL17 24F Armoured Subsea | 24 × G.652.D SM + Strength Armour | Subsea pressure-resistant optical unit | 17.0 | 580 | 95.0 | 255 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × G.652.D / G.657.A2 SM (200 kpsi) | 0.35 | ≤0.35 dB/km @ 1310 nm | −10…+60 °C |
| 12 × G.652.D / G.657.A2 SM (200 kpsi) | 0.22 | ≤0.22 dB/km @ 1550 nm | −10…+60 °C |
| 24 × G.652.D SM + Strength Armour | 0.20 | ≤0.20 dB/km @ 1550 nm | −10…+60 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17) | DC resistance at 20 °C / optical attenuation and outer diameter within ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17) | Zero dielectric breakdown and verified insulation resistance for 12/20 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (ITU-T G.978 / UJC Qualified 15 kV DC Transoceanic SL17) | Verified submersion integrity, tensile load and thermal stability across −10…+60 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.