wind turbine drip-loop, tray & pitch control cableIEC 60502-1 / UL 1000V/2000V600 V / 1,000 V / 2,000 V (-50 to +9TSE / Polyurethane (PUR) Outer Jacke

600 V / 1,000 V / 2,000 V (-50 °C to +90 °C) Foil + TCWB Shielded TSE/PUR Wind Hub Slip-Ring & Pitch Encoder CableIEC 60502-1 / UL 1000V/2000V — 600 V / 1,000 V / 2,000 V — -50 to +90 °C Wind Turbine Cable

600 V / 1,000 V / 2,000 V (-50 °C to +90 °C) Foil + TCWB Shielded TSE/PUR Wind Hub Slip-Ring & Pitch Encoder Cable (IEC 60502-1 / UL 1000V/2000V, 600 V / 1,000 V / 2,000 V, -50 to +90 °C, min. bend radius 5 × OD).

Anti-torsion braid
EMC screen
Oil-resistant
Approved
Order designation
Slip-Ring 4×2×0.75 mm²
Outer Ø ≈
11.8 mm
Net weight ≈
210 kg/km
Max. pulling ≈
1.8 kN
Core / stranding
Ultra-fine Class 6 SnCu + Foil/TCWB
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V / 1,000 V
Tested per IEC 60502-1 / UL 1000V/2000V
Operating temp.
−50…+90 °C
Cold-climate & nacelle wind service
Min. bend radius
5 × OD
Drip-loop, hub & tower routing
Core / conductor
Ultra-Fine Tinne
Bunch-stranded tinned copper cores for s
Outer protection
TSE / Polyuretha
High-flexibility cold- and oil-resistant
Standard
IEC 60502-1 / UL
IEC 60502-1 & UL AWM 600 V/1,000 V/2,000

Typical values for this cable type, based on IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is Slip-Ring & Pitch Control 600V–2kV right for your machine?

600 V / 1,000 V / 2,000 V (-50 °C to +90 °C) Foil + TCWB Shielded TSE/PUR Wind Hub Slip-Ring & Pitch Encoder Cable (IEC 60502-1 / UL 1000V/2000V, 600 V / 1,000 V / 2,000 V, -50 to +90 °C, min. bend radius 5 × OD).

Free-hanging vertical run

Suitable

Class 5, Class 6 and Class K extra-flexible copper cores withstand continuous ±150°/m drip-loop and ±450°/0.5m pitch torsion down to −40/−

Fixed installation

Suitable

UL 2277 WTTC 1,000 V / UL 1277 TC-ER 600 V and IEC 0.6/1 kV ratings allow open tray and Exposed Run routing across the nacelle and tower.

Switchgear & control cabinet wiring

Suitable

Number-coded cores and 85% tinned copper braid / foil+braid shields terminate neatly into pitch servo boxes, slip-rings and PLC cabinets.

Energy chain / drag chain

Suitable

PUR-sheathed Class 6 pitch & slip-ring cables (RT 113/123, RT 114/116) handle combined rotary hub motion and bending.

Vertical / spreader reel

Not suitable

Wind turbine control and tray cable is not engineered for deepwater vertical oceanographic lift winches.

Use A304739 BOP MUX Umbilical
Typical machinesRenewable Energy & EV ChargingWind Turbine Rotor Hub Pitch Control & Slip-RingsNacelle-to-Tower Multi-Core Drip-Loop Control BundlesUL 2277 WTTC / TC-ER Nacelle & Tower Cable TraysBlade De-Icing, Trace Heating & Aviation Obstruction Lights

Construction

Layer by layer

Shown: Slip-Ring & Pitch Control 600V–2kV (IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification) featuring ultra-fine tinned copper conductors / pairs, epr / tpe low-temperature dielectric and tse / polyurethane (pur) outer jacket (-50 °c) (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Ultra-Fine Tinned Copper Conductors / PaBunch-stranded tinned copper cores for slip-ring & pitch encoders
2EPR / TPE Low-Temperature DielectricFlexible elastomeric insulation rated 600 V, 1,000 V and 2,000 V
3Individual Foil & Tinned Copper Braid ShHigh-noise-immunity EMC shielding for pitch servo drives
4TSE / Polyurethane (PUR) Outer Jacket (-High-flexibility cold- and oil-resistant outer sheath

Slip-Ring & Pitch Control 600V–2kV — Standard Wind Turbine Execution

Built to IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification with ultra-fine tinned copper conductors / pairs and tse / polyurethane (pur) outer jacket (-50 °c)

Slip-Ring & Pitch Control 600V–2kV — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

Slip-Ring & Pitch Control 600V–2kV — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
600 V / 1,000 V / 2,000 V (IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification)
Core / conductor construction
Ultra-Fine Tinned Copper Conductors / Pairs — Bunch-stranded tinned copper cores for slip-ring & pitch encoders
Primary dielectric / insulation
EPR / TPE Low-Temperature Dielectric — Flexible elastomeric insulation rated 600 V, 1,000 V and 2,000 V

Thermal

Continuous operating temperature
−50…+90 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −50…+90 °C per IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
TSE / Polyurethane (PUR) Outer Jacket (-50 °C) — High-flexibility cold- and oil-resistant outer sheath
Minimum bending radius
5 × OD
Intermediate screen / separator / core layer
Individual Foil & Tinned Copper Braid Shield — High-noise-immunity EMC shielding for pitch servo drives

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
Slip-Ring & Pitch Control 600V–2kV
Sheath colour & metre marking
Continuous metre-marked black outer finish (TSE / Polyuretha)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard Slip-Ring & Pitch Control 600V–2kV wind turbine configurations

Manufactured to IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
Slip-Ring & Pitch Control 600V–2kV Construction Schedule (−50…+90 °C)
Slip-Ring 4×2×0.75 mm²4 × 2 × 0.75 mm² Screened PairsUltra-fine Class 6 SnCu + Foil/TCWB11.82101.860
Slip-Ring 4×2×1.0 mm²4 × 2 × 1.0 mm² Screened PairsUltra-fine Class 6 SnCu + Foil/TCWB13.22652.470
Slip-Ring 8×2×1.0 + 4G2.58 × 2 × 1.0 + 4G2.5 mm² HybridUltra-fine Class 6 SnCu + Foil/TCWB18.45204.895
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification)DC resistance at 20 °C and insulation/sheath wall thickness within IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification)Zero dielectric breakdown and verified insulation resistance for 600 V / 1,000 V / 2,000 V ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −50…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60502-1 / UL 1000V/2000V CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX Slip-Ring & Pitch Control 600V–2kV IEC 60502-1 / UL 1000V/2000V 600 V / 1,000 V / 2,000 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define Slip-Ring & Pitch Control 600V–2kV (600 V / 1,000 V / 2,000 V (-50 °C to +90 °C) Foil + TCWB Shielded TSE/PUR Wind Hub Slip-Ring & Pitch Encoder Cable)?
Slip-Ring & Pitch Control 600V–2kV (600 V / 1,000 V / 2,000 V (-50 °C to +90 °C) Foil + TCWB Shielded TSE/PUR Wind Hub Slip-Ring & Pitch Encoder Cable) is manufactured in accordance with IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification for 600 V / 1,000 V / 2,000 V wind turbine service over -50 to +90 °C. Its 4-layer construction comprises ultra-fine tinned copper conductors / pairs, epr / tpe low-temperature dielectric and tse / polyurethane (pur) outer jacket (-50 °c).
What is the minimum bending radius and operating temperature range for Slip-Ring & Pitch Control 600V–2kV?
The minimum bending radius for Slip-Ring & Pitch Control 600V–2kV is 5 × OD across its continuous operating temperature range of -50 to +90 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of Slip-Ring & Pitch Control 600V–2kV arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Ultra-Fine Tinned Copper Conductors / Pairs — Bunch-stranded tinned copper cores for slip-ring & pitch encoders; (02) EPR / TPE Low-Temperature Dielectric — Flexible elastomeric insulation rated 600 V, 1,000 V and 2,000 V; (03) Individual Foil & Tinned Copper Braid Shield — High-noise-immunity EMC shielding for pitch servo drives; (04) TSE / Polyurethane (PUR) Outer Jacket (-50 °C) — High-flexibility cold- and oil-resistant outer sheath.
What factory test certificates are supplied with Slip-Ring & Pitch Control 600V–2kV?
Every production drum of Slip-Ring & Pitch Control 600V–2kV undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per IEC 60502-1 & UL AWM 600 V/1,000 V/2,000 V Hub Slip-Ring & Pitch Servo Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for Slip-Ring & Pitch Control 600V–2kV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Slip-Ring & Pitch Control 600V–2kV 600 V / 1,000 V / 2,000 V (-50 °C to +90 °C) Foil + TCWB Shielded TSE/PUR Wind Hub Slip-Ring & Pitch Encoder Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote