Contact

Screened PUR Drag-Chain One-Cable Hybrid Servo CableUL AWM Style 21223 / DIN VDE 0285 · 600/1000 V · -40 °C to +90 °C industrial SL 875 C HMC6

Screened PUR Drag-Chain One-Cable Hybrid Servo Cable engineered to UL AWM Style 21223 / DIN VDE 0285 for 600/1000 V service across -40 °C to +90 °C, featuring stranded copper conductor and matte tmpu outer sheath with minimum bending radius 7.5 × OD.

Approved
Low-EMC design
EMC screen
Oil-resistant
Order designation
SL 875 C HMC6 Servo Hybrid 4G2.5
Outer Ø ≈
10.8 mm
Total weight ≈
186 kg/km
Min. bend R (fixed)
86 mm
Configuration
4 × 2.5 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600/1000 V
Per UL AWM Style 21223 / DIN VDE 0285
Operating temp.
−40…+90 °C
Continuous thermal rating
Min. bend radius
7.5 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
Matte TMPU
Extruded Matte TMPU outer sheath
Standard
UL AWM Style
UL AWM Style 21223 / DIN VDE 0285

Typical values for this cable type, based on UL AWM Style 21223 / DIN VDE 0285 — confirmed in the datasheet and quotation for your order.

Application fit

Is SL 875 C HMC6 Servo Hybrid right for your machine?

Screened PUR Drag-Chain One-Cable Hybrid Servo Cable engineered to UL AWM Style 21223 / DIN VDE 0285 for 600/1000 V service across -40 °C to +90 °C, featuring stranded copper conductor and matte tmpu outer sheath with minimum bending radius 7.5 × OD.

Energy chain / drag chain

Suitable

Engineered and verified for chain service in accordance with UL AWM Style 21223 / DIN VDE 0285.

VFD inverter to AC motor screened feeder

Suitable

Engineered and verified for vfd drive service in accordance with UL AWM Style 21223 / DIN VDE 0285.

Fixed installation

Suitable

Qualified for fixed installation on trays, racks, conduits or supports per UL AWM Style 21223 / DIN VDE 0285.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 7.5 × OD bend radius.

Typical machinesIndustrial Automation CableAutomated Assembly & Packaging LinesCNC Machine Tools & RoboticsPLC/DCS Control & Marshalling CabinetsIndustrial Drives & Motor ManufacturingClosed-Loop Servo Drives & Linear Actuators

Construction

Layer by layer

Shown: SL 875 C HMC6 Servo Hybrid (UL AWM Style 21223 / DIN VDE 0285) with stranded copper conductor, special polymer core insulation and matte tmpu outer sheath (10-layer construction).

12345678910
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per UL AWM Style 21223 / DIN VDE 0285UL AWM Style 21223 / DIN VDE 0285
2Special polymer core insulationExtruded Special polymer dielectric (individual core / group layer)UL AWM Style 21223 / DIN VDE 0285
3Control nonwoven wrapHelically applied control nonwoven wrapUL AWM Style 21223 / DIN VDE 0285
4Control tinned copper braidControl tinned copper braid high-coverage braided layer (individual core / group layer)UL AWM Style 21223 / DIN VDE 0285
5Control separatorHelically applied control separatorUL AWM Style 21223 / DIN VDE 0285
6Feedback nonwoven wrappingHelically applied feedback nonwoven wrappingUL AWM Style 21223 / DIN VDE 0285
7Feedback tinned copper braidFeedback tinned copper braid high-coverage braided layer (individual core / group layer)UL AWM Style 21223 / DIN VDE 0285
8Feedback separatorHelically applied feedback separatorUL AWM Style 21223 / DIN VDE 0285
9Overall nonwoven wrapHelically applied overall nonwoven wrapUL AWM Style 21223 / DIN VDE 0285
10Matte TMPU outer sheathExtruded Matte TMPU outer sheath protective layer (continuous layer)UL AWM Style 21223 / DIN VDE 0285

SL 875 C HMC6 Servo Hybrid — Standard Execution

Built to UL AWM Style 21223 / DIN VDE 0285 with stranded copper conductor and matte tmpu outer sheath

SL 875 C HMC6 Servo Hybrid — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per UL AWM Style 21223 / DIN VDE 0285

SL 875 C HMC6 Servo Hybrid — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL AWM Style 21223 / DIN VDE 0285. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
600/1000 V (UL AWM Style 21223 / DIN VDE 0285)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per UL AWM Style 21223 / DIN VDE 0285
Primary insulation / dielectric
Special polymer core insulation — Extruded Special polymer dielectric (individual core / group layer)

Thermal

Continuous operating temperature
−40…+90 °C per UL AWM Style 21223 / DIN VDE 0285
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
Matte TMPU outer sheath — Extruded Matte TMPU outer sheath protective layer (continuous layer)
Minimum bending radius
7.5 × OD (installed / static routing)
Layer count & geometry
10 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with UL AWM Style 21223 / DIN VDE 0285
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
UL AWM Style 21223 / DIN VDE 0285
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
SL 875 C HMC6 Servo Hybrid
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard SL 875 C HMC6 Servo Hybrid cable sizes

Manufactured to UL AWM Style 21223 / DIN VDE 0285 across standard single-core and multi-core cross-sections.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
SL 875 C HMC6 Servo Hybrid Standard Production Schedule (600/1000 V · −40…+90 °C)
SL 875 C HMC6 Servo Hybrid 3G1.53 × 1.5 mm²8.410568
SL 875 C HMC6 Servo Hybrid 4G1.54 × 1.5 mm²9.212874
SL 875 C HMC6 Servo Hybrid 5G1.55 × 1.5 mm²10.115681
SL 875 C HMC6 Servo Hybrid 3G2.53 × 2.5 mm²9.814878
SL 875 C HMC6 Servo Hybrid 4G2.54 × 2.5 mm²10.818686
SL 875 C HMC6 Servo Hybrid 5G2.55 × 2.5 mm²11.922895
SL 875 C HMC6 Servo Hybrid 4G44 × 4.0 mm²12.6268101
SL 875 C HMC6 Servo Hybrid 4G64 × 6.0 mm²14.2365114
SL 875 C HMC6 Servo Hybrid 4G104 × 10 mm²17.5580140
SL 875 C HMC6 Servo Hybrid 4G164 × 16 mm²20.4845163
SL 875 C HMC6 Servo Hybrid 4G254 × 25 mm²24.81,290198
SL 875 C HMC6 Servo Hybrid 4G354 × 35 mm²27.91,710223
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Single-core and multi-core sizes from 0.5 mm² up to 630 mm² (or AWG/kcmil) available per UL AWM Style 21223 / DIN VDE 0285.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (UL AWM Style 21223 / DIN VDE 0285)DC resistance at 20 °C and geometry within UL AWM Style 21223 / DIN VDE 0285 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (UL AWM Style 21223 / DIN VDE 0285)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (UL AWM Style 21223 / DIN VDE 0285)Full compliance with UL AWM Style 21223 / DIN VDE 0285 across −40…+90 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL AWM Style 21223 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX SL 875 C HMC6 Servo Hybrid <size> UL AWM Style 21223 600/1000 V CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define SL 875 C HMC6 Servo Hybrid (Screened PUR Drag-Chain One-Cable Hybrid Servo Cable)?
SL 875 C HMC6 Servo Hybrid (Screened PUR Drag-Chain One-Cable Hybrid Servo Cable) is manufactured in accordance with UL AWM Style 21223 / DIN VDE 0285 for 600/1000 V service over -40 °C to +90 °C. Its 10-layer construction comprises stranded copper conductor, special polymer core insulation, control nonwoven wrap, control tinned copper braid, control separator, feedback nonwoven wrapping, feedback tinned copper braid, feedback separator, overall nonwoven wrap, matte tmpu outer sheath.
What is the minimum bending radius and installation temperature for SL 875 C HMC6 Servo Hybrid?
The minimum installed bending radius for SL 875 C HMC6 Servo Hybrid is 7.5 × OD across its continuous operating temperature range of -40 °C to +90 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of SL 875 C HMC6 Servo Hybrid arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per UL AWM Style 21223 / DIN VDE 0285); (02) Special polymer core insulation (Extruded Special polymer dielectric (individual core / group layer)); (03) Control nonwoven wrap (Helically applied control nonwoven wrap); (04) Control tinned copper braid (Control tinned copper braid high-coverage braided layer (individual core / group layer)); (05) Control separator (Helically applied control separator); (06) Feedback nonwoven wrapping (Helically applied feedback nonwoven wrapping); (07) Feedback tinned copper braid (Feedback tinned copper braid high-coverage braided layer (individual core / group layer)); (08) Feedback separator (Helically applied feedback separator); (09) Overall nonwoven wrap (Helically applied overall nonwoven wrap); (10) Matte TMPU outer sheath (Extruded Matte TMPU outer sheath protective layer (continuous layer)).
What factory test certificates are supplied with SL 875 C HMC6 Servo Hybrid?
Every production drum or spool of SL 875 C HMC6 Servo Hybrid undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per UL AWM Style 21223 / DIN VDE 0285, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for SL 875 C HMC6 Servo Hybrid

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

SL 875 C HMC6 Servo Hybrid Screened PUR Drag-Chain One-Cable Hybrid Servo Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote