Contact
Rubber cablesDIN VDE 0250 / UL 45370.6/1 kV (95–300 mm²)±100°/m Spiral EMC

S-3GDSHÖU 0.6/1kV UL 4537 Single-Core Wind Torsion CableSpiral-screened 3GI3 EPR and 5GM3 CPE single-core wind turbine cable

Single-core 0.6/1 kV (1,000 V UL Style 4537) wind turbine loop feeder with Class 5 bare copper, 3GI3 EPR insulation, >90% tinned copper spiral screen and black 5GM3 CPE sheath.

Anti-torsion braid
Low-EMC design
Oil-resistant
Flame-retardant
Order designation
S-3GDSHÖU 1×150
Outer Ø ≈
27.8 mm
Weight ≈
1,860 kg/km
Max. DCR
0.1290 Ω/km
Flex bend R
167 mm
All sizes (6)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
1,000 V UL Style 4537 · 4 kV test
Torsion rating
±100°/m
Bidirectional nacelle yaw twisting
Operating temp.
-40 to +90 °C
Moving & fixed · +250 °C SC
EMC screen
>90% TC spiral
Helically spun tinned Cu wires
Outer sheath
5GM3 CPE
Oil-, UV- & ozone-resistant rubber
Standard sizes
95–300 mm²
6 heavy single-core feeder sizes

Typical values for this cable type, based on DIN VDE 0250 & UL Style 4537 / 3775 — confirmed in the datasheet and quotation for your order.

Application fit

Is S-3GDSHÖU 0.6/1kV UL 4537 right for your machine?

Single-core 0.6/1 kV (1,000 V UL Style 4537) wind turbine loop feeder with Class 5 bare copper, 3GI3 EPR insulation, >90% tinned copper spiral screen and black 5GM3 CPE sheath.

Free-hanging vertical run

Suitable

Helically spun copper screen and Class 5 bare copper handle ±100°/m hanging wind loop torsion.

VFD inverter to AC motor screened feeder

Suitable

>90% tinned copper spiral screen suppresses electromagnetic emissions on high-power turbine converters.

Fixed installation

Suitable

5GM3 CPE elastomer jacket resists gear oils, hydraulic fluids, UV and ozone throughout the tower.

Motorised monospiral reel

Not suitable

Single-core spiral-screened wind feeder is not built for horizontal crane reeling drums.

Use NSHTÖU Reeling Cable

Immersion & wet locations

Not suitable

Not rated for permanent underwater submersion; select dynamic subsea cables for marine wet runs.

Use RJIT Subsea Cable

Wind turbine tower & nacelle

Suitable

Cold-flex and torsion-tested 0.6/1 kV EPR/CPE construction supports wind turbine tower risers, yaw loops, and nacelle switchgear.

Typical machinesRenewable Energy & EV ChargingMulti-Megawatt Wind TurbinesNacelle Generator-to-Tower LoopsOffshore & Cold-Climate WindHigh-Current VFD Converter Drops

Construction

Layer by layer

Shown: S-3GDSHÖU 1×150 mm² (OD 27.8 mm) — Class 5 plain copper, 3GI3 EPR insulation (UL Style 3775), separator wrap, >90% tinned copper spiral screen and black 5GM3 CPE outer sheath.

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorDIN EN 60228 Class 5 fine-stranded plain bare copperIEC 60228 Class 5
2Core insulation90 °C 3GI3 thermoset EPR rubber insulation with separator wrapUL Style 3775 / VDE 0207
3Spiral copper screen>90% optical coverage helically spun tinned copper wire screenBidirectional torsion EMC
4Outer sheathBlack 5GM3 chlorinated polyethylene (CPE) rubber outer sheathUL Style 4537 / 5GM3

Single-Core Spiral Screen (D)

95–300 mm² single-core helically screened main turbine loop feeders

Multi-Core Braided LSOH (C)

See S-3GCSHXOEU UL 21465 for multi-core braided LSOH auxiliary loops

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0250 & UL Style 4537 / 3775. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
0.6/1 kV (1,000 V UL Style 4537)
Max. operating voltage AC
0.7/1.2 kV AC (DIN VDE 0298-3)
AC test voltage
4.0 kV AC (5 min)
Screen / Field control
>90% tinned Cu spiral wire screen
Conductor resistance (150 mm²)
≤ 0.129 Ω/km at 20 °C

Thermal

Temperature, flexing
-40 °C to +90 °C
Temperature, fixed installation
-40 °C to +90 °C
Max. conductor temperature
+90 °C
Short-circuit temperature
+250 °C (max. 5 s)

Mechanical

Torsional stress
±100°/m bidirectional yaw twisting
Min. bending radius, moving
6 × OD
Min. bending radius, fixed
4 × OD

Resistance

Oil resistance
Synthetic gear & hydraulic oils (5GM3)
Flame retardance
IEC 60332-1-2 & UL VW-1 / FT2
UV & ozone
UV-, ozone- & weather-resistant CPE

Reference standards

Cable type
Based on DIN VDE 0250 / UL Style 4537
Conductor
DIN EN 60228 Class 5 plain copper
Compounds
3GI3 EPR (UL 3775) / 5GM3 CPE (UL 4537)
RoHS
RoHS 2 (2011/65/EU) & REACH compliant

Identification

Sheath colour
Black 5GM3 CPE rubber
Core identification
Natural / cream 3GI3 insulation
Marking
S-3GDSHÖU 0.6/1kV UL 4537 TEBAOFLEX.COM
Customs tariff (HS)
8544.49 (confirm nationally)

Sizes

6 standard sizes

Typical single-core 95–300 mm² spiral-screened wind torsion dimensions. 400 mm² and tinned conductor options on request.

Dimensions & weights
Order designationCores × mm²AWG / kcmil ≈Outer Ø ≈
mm
Max. DCR 20 °C
Ω/km
Weight ≈
kg/km
Flex bend R
mm
Enquiry
Single-core 0.6/1 kV spiral-screened
S-3GDSHÖU 1×951 × 95 mm²3/0 AWG23.40.20601,240140
S-3GDSHÖU 1×1201 × 120 mm²4/0 AWG25.50.16101,520153
S-3GDSHÖU 1×1501 × 150 mm²300 kcmil27.80.12901,860167
S-3GDSHÖU 1×1851 × 185 mm²350 kcmil30.60.10602,270184
S-3GDSHÖU 1×2401 × 240 mm²500 kcmil34.40.08012,910206
S-3GDSHÖU 1×3001 × 300 mm²600 kcmil38.20.06413,620229
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Representative 1×150 mm² build has nominal outer diameter 27.8 mm (conductor Ø ≈ 16.0 mm). Max. DC resistance at 20 °C per IEC 60228 Table 3 (Class 5 plain Cu).

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC high-voltage withstand test4.0 kV AC for 5 min without breakdownEvery length
Conductor DC resistance & screen checkIEC 60228 Class 5 plain Cu; >90% spiral wire continuityEvery length
Sample tests
Bidirectional torsion fatigue & oil immersion±100°/m cold torsion (-40 °C), 5GM3 oil resistance & IEC 60332-1-2Type qualification

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0250 & UL Style 4537 / 3775 design complianceEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

S-3GDSHÖU 0.6/1kV UL 4537 TEBAOFLEX.COM
Delivery form
Export wooden drums or cut-to-length kits
Standard lengths
500 m, 1,000 m or turbine-loop cut lengths
MOQ
100 m (standard sizes) · 500 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-19
Updated
2026-11-19

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

Why does S-3GDSHÖU use a spiral wire screen instead of a woven copper braid?
In large single-core wind turbine feeders from 95 to 300 mm², a helically spun (>90% coverage) tinned copper wire screen ('D' in the VDE code) slips smoothly during bidirectional ±100°/m yaw twisting without the wire-crossover fatigue common in tightly woven braids.
What is the advantage of the 5GM3 CPE outer sheath on wind turbine loops?
The 5GM3 chlorinated polyethylene (CPE) elastomer sheath rated to UL Style 4537 provides strong resistance to synthetic turbine gear oils, hydraulic fluids, UV radiation, ozone and cold-climate flexing down to -40 °C.
What UL styles and VDE compounds define S-3GDSHÖU?
The cable pairs 90 °C 3GI3 thermoset EPR insulation conforming to UL Style 3775 with a black 5GM3 CPE outer jacket conforming to UL Style 4537 and DIN VDE 0250 guidelines for 0.6/1 kV (1,000 V UL) service.
Is a halogen-free multi-core alternative available for auxiliary wind circuits?
Yes. For multi-core 4G auxiliary power and converter loops requiring a halogen-free LSOH sheath and braided screen, select S-3GCSHXOEU 0.6/1 kV UL 21465.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for S-3GDSHÖU 0.6/1kV UL 4537

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

S-3GDSHÖU 0.6/1kV UL 4537 Single-Core Wind Torsion Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote