Free-hanging vertical run
Helically spun copper screen and Class 5 bare copper handle ±100°/m hanging wind loop torsion.
Product
Single-core 0.6/1 kV (1,000 V UL Style 4537) wind turbine loop feeder with Class 5 bare copper, 3GI3 EPR insulation, >90% tinned copper spiral screen and black 5GM3 CPE sheath.
Typical values for this cable type, based on DIN VDE 0250 & UL Style 4537 / 3775 — confirmed in the datasheet and quotation for your order.
Application fit
Single-core 0.6/1 kV (1,000 V UL Style 4537) wind turbine loop feeder with Class 5 bare copper, 3GI3 EPR insulation, >90% tinned copper spiral screen and black 5GM3 CPE sheath.
Helically spun copper screen and Class 5 bare copper handle ±100°/m hanging wind loop torsion.
>90% tinned copper spiral screen suppresses electromagnetic emissions on high-power turbine converters.
5GM3 CPE elastomer jacket resists gear oils, hydraulic fluids, UV and ozone throughout the tower.
Single-core spiral-screened wind feeder is not built for horizontal crane reeling drums.
Use NSHTÖU Reeling CableNot rated for permanent underwater submersion; select dynamic subsea cables for marine wet runs.
Use RJIT Subsea CableCold-flex and torsion-tested 0.6/1 kV EPR/CPE construction supports wind turbine tower risers, yaw loops, and nacelle switchgear.
Construction
Shown: S-3GDSHÖU 1×150 mm² (OD 27.8 mm) — Class 5 plain copper, 3GI3 EPR insulation (UL Style 3775), separator wrap, >90% tinned copper spiral screen and black 5GM3 CPE outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | DIN EN 60228 Class 5 fine-stranded plain bare copperIEC 60228 Class 5 |
| 2 | Core insulation | 90 °C 3GI3 thermoset EPR rubber insulation with separator wrapUL Style 3775 / VDE 0207 |
| 3 | Spiral copper screen | >90% optical coverage helically spun tinned copper wire screenBidirectional torsion EMC |
| 4 | Outer sheath | Black 5GM3 chlorinated polyethylene (CPE) rubber outer sheathUL Style 4537 / 5GM3 |
95–300 mm² single-core helically screened main turbine loop feeders
See S-3GCSHXOEU UL 21465 for multi-core braided LSOH auxiliary loops
Technical data
Sizes
Typical single-core 95–300 mm² spiral-screened wind torsion dimensions. 400 mm² and tinned conductor options on request.
| Order designation | Cores × mm² | AWG / kcmil ≈ | Outer Ø ≈ mm | Max. DCR 20 °C Ω/km | Weight ≈ kg/km | Flex bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Single-core 0.6/1 kV spiral-screened | |||||||
| S-3GDSHÖU 1×95 | 1 × 95 mm² | 3/0 AWG | 23.4 | 0.2060 | 1,240 | 140 | |
| S-3GDSHÖU 1×120 | 1 × 120 mm² | 4/0 AWG | 25.5 | 0.1610 | 1,520 | 153 | |
| S-3GDSHÖU 1×150 | 1 × 150 mm² | 300 kcmil | 27.8 | 0.1290 | 1,860 | 167 | |
| S-3GDSHÖU 1×185 | 1 × 185 mm² | 350 kcmil | 30.6 | 0.1060 | 2,270 | 184 | |
| S-3GDSHÖU 1×240 | 1 × 240 mm² | 500 kcmil | 34.4 | 0.0801 | 2,910 | 206 | |
| S-3GDSHÖU 1×300 | 1 × 300 mm² | 600 kcmil | 38.2 | 0.0641 | 3,620 | 229 | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage withstand test | 4.0 kV AC for 5 min without breakdown | Every length |
| Conductor DC resistance & screen check | IEC 60228 Class 5 plain Cu; >90% spiral wire continuity | Every length |
| Sample tests | ||
| Bidirectional torsion fatigue & oil immersion | ±100°/m cold torsion (-40 °C), 5GM3 oil resistance & IEC 60332-1-2 | Type qualification |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.