Contact
Subsea umbilical cablesIEC 60502-11.8/3 (3.6) kV3-Core + 12F Optical

RJIT 1.8/3 (3.6) kV Dynamic Subsea Electro-Optical CableDynamic wave and tidal 3-core TPE-E power plus 12-fibre PUR cable

Dynamic 1.8/3 (3.6) kV marine electro-optical power cable with Class 6 tinned copper, TPE-E insulation, central 12-fibre telemetry unit, polyaramid braid and yellow PUR sheath.

Water-resistant
Ozone, UV & moisture
Oil-resistant
Anti-torsion braid
Order designation
RJIT 1.8/3 kV 3×50 + 12F
Outer Ø ≈
40.0 mm
Weight ≈
2,420 kg/km
Max. DCR
0.393 Ω/km
Dynamic bend R
400 mm
All sizes (5)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1.8/3 (3.6) kV
AC test 6.5 kV · IEC 60502-1
Optical unit
12F G.652D
Central nano telemetry subunit
Operating temp.
-20 to +90 °C
Permanent seawater submersion
Min. bend radius
10 × OD
Dynamic wave/tidal · 6 × OD static
Strength layer
Polyaramid
High-modulus tensile yarn braid
Standard sizes
25–95 mm²
5 hybrid 3-core + 12F builds

Typical values for this cable type, based on IEC 60502-1 (applicable parts) & IEC 60228 Class 6 — confirmed in the datasheet and quotation for your order.

Application fit

Is RJIT 1.8/3 (3.6) kV right for your machine?

Dynamic 1.8/3 (3.6) kV marine electro-optical power cable with Class 6 tinned copper, TPE-E insulation, central 12-fibre telemetry unit, polyaramid braid and yellow PUR sheath.

Immersion & wet locations

Suitable

Hydrolysis-resistant yellow PUR jacket and TPE-E insulation operate under permanent dynamic seawater submersion.

Offshore platform & shipboard deck trays

Suitable

High-visibility UV- and abrasion-resistant PUR jacket handles splash zones and dynamic marine launch.

Free-hanging vertical run

Suitable

Braided polyaramid yarn strength layer supports dynamic catenary and lazy-wave subsea suspension.

Cylindrical / multi-layer drum

With conditions

Suitable for deployment and recovery winches respecting the 10 × OD dynamic bend radius.

Energy chain / drag chain

Not suitable

Heavy subsea electro-optical umbilical is not intended for dry industrial energy-chain carriers.

Use Drag-Chain Cable

Offshore seabed umbilical & riser

Suitable

Hydrostatic-resistant PUR/TPE design supports offshore seabed umbilical, riser, and subsea production tie-back runs.

Typical machinesMarine & Offshore CableWave Energy Converters (WEC)Tidal Stream Turbines (TEC)Floating Offshore Research BuoysDynamic Subsea Marine Risers

Construction

Layer by layer

Shown: RJIT 3×50 mm² + 12F (OD 40 mm) — Class 6 tinned copper power cores in Brown/Black/Grey TPE-E, central 12F nano optical unit, polyaramid braid and yellow PUR sheath.

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Power conductorsIEC 60228 Class 6 extra-flexible annealed tinned copperIEC 60228 Class 6
2Core insulation90 °C thermoplastic polyester elastomer (TPE-E), Brown, Black & GreyHD 308 S2
312-fibre optical subunitCentral 12-fibre ITU-T G.652D nano optical unit with 3 black fillersITU-T G.652D
4Tensile reinforcementHigh-modulus braided polyaramid yarn tensile strength layerDynamic fatigue load
5Outer sheathYellow dynamic marine-grade polyurethane (PUR) outer sheathPermanent submersion

3-Core + 12F SM (Standard)

Three Class 6 power cores with central 12-fibre single-mode G.652D telemetry unit

Custom Fibre / Earth Option

24F optical units, multimode OM3/OM4 or interstitial earth cores on request

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60502-1 (applicable parts) & IEC 60228 Class 6. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
1.8/3 (3.6) kV AC
AC test voltage
6.5 kV AC (5 min)
Conductor resistance (50 mm²)
≤ 0.393 Ω/km at 20 °C
Insulation system
90 °C TPE-E dielectric

Thermal

Temperature, flexing
-20 °C to +90 °C (dynamic subsea)
Temperature, fixed installation
-40 °C to +90 °C
Max. conductor temperature
+90 °C
Short-circuit temperature
+250 °C (max. 5 s)

Mechanical

Min. bending radius, moving
10 × OD (dynamic wave/tidal)
Min. bending radius, fixed
6 × OD
Tensile reinforcement
Braided polyaramid yarn layer

Optical

Fibre type
Single-mode ITU-T G.652D (9/125 µm)
Fibre count
12 fibres (nano optical unit)
Attenuation
≤ 0.38 dB/km @ 1310 nm · ≤ 0.25 @ 1550 nm

Resistance

Water
Permanent dynamic seawater immersion
Abrasion
High-tear marine PUR outer sheath
UV & ozone
UV-, ozone- & microbe-resistant PUR
Oil resistance
Resistant to marine & hydraulic oils

Reference standards

Cable type
IEC 60502-1 (applicable parts)
Conductor
IEC 60228 Class 6 tinned copper
Optical subunit
ITU-T G.652D / IEC 60794-1
RoHS
RoHS 2 (2011/65/EU) & REACH compliant

Identification

Sheath colour
High-visibility yellow PUR
Core identification
Brown, Black, Grey (HD 308 S2)
Marking
RJIT 1.8/3 (3.6) kV IEC 60502-1 TEBAOFLEX.COM
Customs tariff (HS)
8544.60 (confirm nationally)

Sizes

5 standard sizes

Typical dynamic subsea electro-optical builds with 12-fibre G.652D telemetry unit. Custom power and fibre counts on request.

Dimensions & weights
Order designationConfigurationOuter Ø ≈
mm
Max. DCR 20 °C
Ω/km
Weight in air ≈
kg/km
Dynamic bend R
mm
Enquiry
1.8/3 (3.6) kV 3-core + 12F optical
RJIT 1.8/3 kV 3×25 + 12F3 × 25 mm² + 12F SM33.50.7951,480335
RJIT 1.8/3 kV 3×35 + 12F3 × 35 mm² + 12F SM36.80.5651,890368
RJIT 1.8/3 kV 3×50 + 12F3 × 50 mm² + 12F SM40.00.3932,420400
RJIT 1.8/3 kV 3×70 + 12F3 × 70 mm² + 12F SM44.50.2773,180445
RJIT 1.8/3 kV 3×95 + 12F3 × 95 mm² + 12F SM49.20.2104,120492
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Representative 3×50 mm² + 12F build has nominal outer diameter 40.0 mm. Wet weight and tensile break load confirmed with project quotation.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC high-voltage withstand test6.5 kV AC for 5 min per IEC 60502-1Every length
OTDR optical attenuation & conductor DCRAll 12 fibres ≤ 0.38/0.25 dB/km; DCR within IEC 60228 Class 6Every length
Sample tests
Cyclic flex-fatigue & seawater hydrolysis checkVerified tensile, bend-over-sheave & PUR jacket integrityType qualification

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60502-1 (applicable parts) & IEC 60228 Class 6 design complianceEN 10204 3.1 Factory Electrical & OTDR Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

RJIT 1.8/3 (3.6) kV IEC 60502-1 TEBAOFLEX.COM
Delivery form
Heavy-duty steel marine reels
Standard lengths
Continuous project lengths up to 2,000 m
MOQ
100 m (standard sizes) · 500 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-19
Updated
2026-11-19

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is RJIT 1.8/3 (3.6) kV designed for?
RJIT 1.8/3 (3.6) kV is built for dynamic marine renewable energy systems including wave energy converters, tidal stream turbines and floating offshore instrumentation buoys that require medium-voltage power export alongside 12-fibre optical telemetry in one flexible subsea cable.
Why does RJIT use TPE-E insulation and a yellow PUR outer sheath?
Thermoplastic polyester elastomer (TPE-E) delivers high dielectric strength, 90 °C thermal stability and slim core diameters under cyclic bending, while the high-visibility yellow polyurethane (PUR) jacket resists seawater hydrolysis, tearing, abrasion and marine micro-organisms.
How are dynamic pulling loads carried without straining the optical fibres?
A high-modulus braided polyaramid yarn strength layer surrounds the laid-up cores to absorb dynamic wave and suspension tension, while the 12-fibre nano optical subunit sits along the neutral central axis of the cable.
What optical fibre types and routine tests are supplied?
Standard builds integrate 12 single-mode ITU-T G.652D fibres with attenuation verified by 100% OTDR testing at 1310 nm and 1550 nm alongside 6.5 kV AC routine dielectric testing and an EN 10204 3.1 factory certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for RJIT 1.8/3 (3.6) kV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

RJIT 1.8/3 (3.6) kV Dynamic Subsea Electro-Optical Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote