Contact
Rubber cablesDIN VDE 0250 / UL 214650.6/1 kV (-40…+90 °C)±100°/m EMC Torsion

S-3GCSHXOEU 0.6/1kV UL 21465 Wind Torsion Power CableBraided EMC LSOH rubber torsion-resistant cable for wind turbine loops

Screened 0.6/1 kV (1,000 V UL Style 21465) wind turbine torsion cable with Class 5 tinned copper, 3GI3 EPR insulation, >90% tinned copper braid and black HXM1 LSOH sheath.

Anti-torsion braid
Low-EMC design
Flame-retardant
Oil-resistant
Order designation
S-3GCSHXOEU 4G10
Outer Ø ≈
26.0 mm
Weight ≈
1,030 kg/km
Max. DCR
1.950 Ω/km
Flex bend R
156 mm
All sizes (9)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
1,000 V UL Style 21465 · 4 kV test
Torsion rating
±100°/m
Nacelle-to-tower yaw drip loop
Operating temp.
-40 to +90 °C
Flexing & fixed cold-climate wind
EMC screen
>90% TC braid
≤ 10 mΩ/m transfer impedance
Outer sheath
HXM1 LSOH
Oil-, UV-, ozone- & cold-resistant
Standard sizes
4G1.5–4G50
9 multi-core power & auxiliary sizes

Typical values for this cable type, based on DIN VDE 0250 & UL Style 21465 — confirmed in the datasheet and quotation for your order.

Application fit

Is S-3GCSHXOEU 0.6/1kV UL 21465 right for your machine?

Screened 0.6/1 kV (1,000 V UL Style 21465) wind turbine torsion cable with Class 5 tinned copper, 3GI3 EPR insulation, >90% tinned copper braid and black HXM1 LSOH sheath.

Free-hanging vertical run

Suitable

Engineered for free-hanging wind turbine tower drip loops under ±100°/m cyclic yaw torsion.

VFD inverter to AC motor screened feeder

Suitable

>90% tinned copper braid keeps transfer impedance ≤ 10 mΩ/m for turbine converter and pitch drives.

Fixed installation

Suitable

Halogen-free HXM1 LSOH outer jacket meets tower-interior fixed routing and fire-safety requirements.

Motorised monospiral reel

Not suitable

Wind loop torsion cable is not designed for horizontal crane reeling drums.

Use NSHTÖU Reeling Cable

Immersion & wet locations

Not suitable

Not rated for permanent underwater submersion; use dynamic subsea cables for marine risers.

Use RJIT Subsea Cable

Wind turbine tower & nacelle

Suitable

Cold-flex and torsion-tested 0.6/1 kV EPR construction supports wind turbine tower risers, yaw loops, and nacelle switchgear.

Typical machinesRenewable Energy & EV ChargingOnshore & Offshore Wind TurbinesNacelle-to-Tower Yaw LoopsWind Turbine Converter CabinetsCold-Climate Utility Wind Farms

Construction

Layer by layer

Shown: S-3GCSHXOEU 4G10 mm² (OD 26 mm) — Class 5 tinned copper, 3GI3 EPR cores (Brown, Black, Grey, Green/Yellow), GM1b rubber inner sheath, >90% tinned Cu braid and black HXM1 LSOH sheath.

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorDIN EN 60228 Class 5 fine-stranded tinned copperDIN EN 60228 Class 5
2Core insulation90 °C 3GI3 thermoset EPR rubber (Brown, Black, Grey, Green/Yellow)DIN VDE 0207 / HD 308
3Inner sheathExtruded cream GM1b torsion-stabilising rubber inner sheathTorsion core bedding
4EMC braid screen>90% optical coverage tinned copper wire braid (≤ 10 mΩ/m)EMC shielding
5Outer sheathBlack HXM1 LSOH oil-, UV-, ozone- & cold-resistant rubber sheathUL Style 21465

4G Multi-Core (J)

Three phase cores plus green-yellow protective earth per HD 308

Single-Core Heavy Feeder

See S-3GDSHÖU UL 4537 for 95–300 mm² single-core spiral-screened feeders

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0250 & UL Style 21465. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
0.6/1 kV (1,000 V UL Style 21465)
Max. operating voltage AC
0.7/1.2 kV AC (DIN VDE 0298-3)
AC test voltage
4.0 kV AC (5 min)
Screen / Field control
>90% TC braid · ≤ 10 mΩ/m
Conductor resistance (10 mm²)
≤ 1.95 Ω/km at 20 °C

Thermal

Temperature, flexing
-40 °C to +90 °C
Temperature, fixed installation
-40 °C to +90 °C
Max. conductor temperature
+90 °C
Short-circuit temperature
+250 °C (max. 5 s)

Mechanical

Torsional stress
±100°/m continuous yaw loop
Min. bending radius, moving
6 × OD
Min. bending radius, fixed
4 × OD

Resistance

Oil resistance
Mineral & synthetic turbine oils
Flame retardance
IEC 60332-1-2 & UL VW-1 / FT2
Halogen-free / Smoke density
IEC 60754-1/2 & IEC 61034-2
UV & ozone
UV-, ozone- & cold-flex (-40 °C) rated

Reference standards

Cable type
Based on DIN VDE 0250 / UL Style 21465
Conductor
DIN EN 60228 Class 5 tinned Cu
Compounds
3GI3 EPR / GM1b inner / HXM1 LSOH
RoHS
RoHS 2 (2011/65/EU) & REACH compliant

Identification

Sheath colour
Black HXM1 LSOH rubber
Core identification
HD 308 S2 (BN, BK, GY, GN/YE)
Marking
S-3GCSHXOEU 0.6/1kV UL 21465 TEBAOFLEX.COM
Customs tariff (HS)
8544.49 (confirm nationally)

Sizes

9 standard sizes

Typical 4G multi-core wind turbine torsion dimensions. 3G, 5G and control-pair counts on request.

Dimensions & weights
Order designationCores × mm²AWG ≈Outer Ø ≈
mm
Max. DCR 20 °C
Ω/km
Weight ≈
kg/km
Flex bend R
mm
Enquiry
4G braided EMC wind torsion
S-3GCSHXOEU 4G1.54G1.5 mm²16 AWG14.513.70028587
S-3GCSHXOEU 4G2.54G2.5 mm²14 AWG16.48.21037598
S-3GCSHXOEU 4G44G4 mm²12 AWG19.05.090520114
S-3GCSHXOEU 4G64G6 mm²10 AWG21.53.390685129
S-3GCSHXOEU 4G104G10 mm²8 AWG26.01.9501,030156
S-3GCSHXOEU 4G164G16 mm²6 AWG29.81.2401,420179
S-3GCSHXOEU 4G254G25 mm²4 AWG34.50.7951,990207
S-3GCSHXOEU 4G354G35 mm²2 AWG38.60.5652,610232
S-3GCSHXOEU 4G504G50 mm²1 AWG44.20.3933,560265
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Representative 4G10 mm² construction has nominal outer diameter 26.0 mm. Max. DC resistance at 20 °C per IEC 60228 Table 3 (Class 5 tinned Cu).

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC high-voltage spark & withstand test4.0 kV AC for 5 min without breakdownEvery length
Conductor resistance & screen continuityIEC 60228 Class 5 tinned Cu; >90% braid continuityEvery length
Sample tests
Cold torsion fatigue & halogen-free fire check±100°/m torsion @ -40 °C, IEC 60332-1-2, IEC 60754 & 61034Type qualification

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0250 & UL Style 21465 design complianceEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

S-3GCSHXOEU 0.6/1kV UL 21465 TEBAOFLEX.COM
Delivery form
Export wooden drums or cut-to-length kits
Standard lengths
500 m, 1,000 m or turbine-loop cut lengths
MOQ
100 m (standard sizes) · 500 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-19
Updated
2026-11-19

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

Why does S-3GCSHXOEU include a GM1b inner sheath under the tinned copper braid?
The extruded GM1b rubber inner sheath stabilises the four twisted 3GI3 EPR cores during repeated ±100°/m yaw twisting in the wind turbine tower loop, keeping the >90% tinned copper braid concentric and preventing mechanical chafing between cores and screen wires.
What is the role of the HXM1 LSOH outer sheath in wind turbine towers?
HXM1 is a halogen-free, low-smoke thermoset rubber jacket formulated for enclosed turbine towers and nacelles: it remains flexible down to -40 °C under cyclic torsion while resisting hydraulic oils, gear lubricants, UV and ozone.
How does S-3GCSHXOEU compare with S-3GDSHÖU UL 4537?
S-3GCSHXOEU is a multi-core (such as 4G10 mm²) LSOH cable with a tinned copper wire braid for auxiliary power and converter circuits, whereas S-3GDSHÖU UL 4537 is a heavy single-core (95–300 mm²) spiral-screened CPE feeder built for high-current main generator loops.
What voltage and temperature ratings apply to S-3GCSHXOEU?
It is rated 0.6/1 kV under DIN VDE 0250 and 1,000 V under UL AWM Style 21465, with continuous flexing and fixed operation across -40 °C to +90 °C and a 250 °C five-second short-circuit limit.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for S-3GCSHXOEU 0.6/1kV UL 21465

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

S-3GCSHXOEU 0.6/1kV UL 21465 Wind Torsion Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote