Free-hanging vertical run
Engineered for free-hanging wind turbine tower drip loops under ±100°/m cyclic yaw torsion.
Product
Screened 0.6/1 kV (1,000 V UL Style 21465) wind turbine torsion cable with Class 5 tinned copper, 3GI3 EPR insulation, >90% tinned copper braid and black HXM1 LSOH sheath.
Typical values for this cable type, based on DIN VDE 0250 & UL Style 21465 — confirmed in the datasheet and quotation for your order.
Application fit
Screened 0.6/1 kV (1,000 V UL Style 21465) wind turbine torsion cable with Class 5 tinned copper, 3GI3 EPR insulation, >90% tinned copper braid and black HXM1 LSOH sheath.
Engineered for free-hanging wind turbine tower drip loops under ±100°/m cyclic yaw torsion.
>90% tinned copper braid keeps transfer impedance ≤ 10 mΩ/m for turbine converter and pitch drives.
Halogen-free HXM1 LSOH outer jacket meets tower-interior fixed routing and fire-safety requirements.
Wind loop torsion cable is not designed for horizontal crane reeling drums.
Use NSHTÖU Reeling CableNot rated for permanent underwater submersion; use dynamic subsea cables for marine risers.
Use RJIT Subsea CableCold-flex and torsion-tested 0.6/1 kV EPR construction supports wind turbine tower risers, yaw loops, and nacelle switchgear.
Construction
Shown: S-3GCSHXOEU 4G10 mm² (OD 26 mm) — Class 5 tinned copper, 3GI3 EPR cores (Brown, Black, Grey, Green/Yellow), GM1b rubber inner sheath, >90% tinned Cu braid and black HXM1 LSOH sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | DIN EN 60228 Class 5 fine-stranded tinned copperDIN EN 60228 Class 5 |
| 2 | Core insulation | 90 °C 3GI3 thermoset EPR rubber (Brown, Black, Grey, Green/Yellow)DIN VDE 0207 / HD 308 |
| 3 | Inner sheath | Extruded cream GM1b torsion-stabilising rubber inner sheathTorsion core bedding |
| 4 | EMC braid screen | >90% optical coverage tinned copper wire braid (≤ 10 mΩ/m)EMC shielding |
| 5 | Outer sheath | Black HXM1 LSOH oil-, UV-, ozone- & cold-resistant rubber sheathUL Style 21465 |
Three phase cores plus green-yellow protective earth per HD 308
See S-3GDSHÖU UL 4537 for 95–300 mm² single-core spiral-screened feeders
Technical data
Sizes
Typical 4G multi-core wind turbine torsion dimensions. 3G, 5G and control-pair counts on request.
| Order designation | Cores × mm² | AWG ≈ | Outer Ø ≈ mm | Max. DCR 20 °C Ω/km | Weight ≈ kg/km | Flex bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 4G braided EMC wind torsion | |||||||
| S-3GCSHXOEU 4G1.5 | 4G1.5 mm² | 16 AWG | 14.5 | 13.700 | 285 | 87 | |
| S-3GCSHXOEU 4G2.5 | 4G2.5 mm² | 14 AWG | 16.4 | 8.210 | 375 | 98 | |
| S-3GCSHXOEU 4G4 | 4G4 mm² | 12 AWG | 19.0 | 5.090 | 520 | 114 | |
| S-3GCSHXOEU 4G6 | 4G6 mm² | 10 AWG | 21.5 | 3.390 | 685 | 129 | |
| S-3GCSHXOEU 4G10 | 4G10 mm² | 8 AWG | 26.0 | 1.950 | 1,030 | 156 | |
| S-3GCSHXOEU 4G16 | 4G16 mm² | 6 AWG | 29.8 | 1.240 | 1,420 | 179 | |
| S-3GCSHXOEU 4G25 | 4G25 mm² | 4 AWG | 34.5 | 0.795 | 1,990 | 207 | |
| S-3GCSHXOEU 4G35 | 4G35 mm² | 2 AWG | 38.6 | 0.565 | 2,610 | 232 | |
| S-3GCSHXOEU 4G50 | 4G50 mm² | 1 AWG | 44.2 | 0.393 | 3,560 | 265 | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage spark & withstand test | 4.0 kV AC for 5 min without breakdown | Every length |
| Conductor resistance & screen continuity | IEC 60228 Class 5 tinned Cu; >90% braid continuity | Every length |
| Sample tests | ||
| Cold torsion fatigue & halogen-free fire check | ±100°/m torsion @ -40 °C, IEC 60332-1-2, IEC 60754 & 61034 | Type qualification |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.