Free-hanging vertical run
Cross-linked EPR/HEPR insulation and 5GM5 / XL-EVA halogen-free jacket withstand ±100°/m to ±180°/m yaw drip-loop torsion at −40 °C.
Product
Global Dual-Standard 1.8/3 (3.6) kV (IEC 60502-1) & 2,000 V (UL RHW-2 / WTTC) LSOH Wind Torsion Cable (IEC 60502-1 / UL 44 RHW-2) engineered for 1.8/3 kV / 2,000 V wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on IEC 60502-1 (1.8/3 kV) & UL 44 RHW-2 / UL 2277 (2,000 V) Dual-Standard Wind Specification — confirmed in the datasheet and quotation for your order.
Application fit
Global Dual-Standard 1.8/3 (3.6) kV (IEC 60502-1) & 2,000 V (UL RHW-2 / WTTC) LSOH Wind Torsion Cable (IEC 60502-1 / UL 44 RHW-2) engineered for 1.8/3 kV / 2,000 V wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Cross-linked EPR/HEPR insulation and 5GM5 / XL-EVA halogen-free jacket withstand ±100°/m to ±180°/m yaw drip-loop torsion at −40 °C.
IEC 60332-3 flame-retardant low-smoke zero-halogen (LSZH) outer sheath routes safely through vertical wind tower ladders and cleats.
Oil-, ozone-, UV- and salt-mist-resistant thermoset EVA/elastomer sheath endures both onshore and offshore wind nacelle environments.
Finely stranded IEC 60228 Class 5 copper or AA8000 Al-alloy conductors terminate cleanly into generator, converter and transformer lugs.
Wind turbine drip-loop torsion and fixed tower cables are not designed for high-speed horizontal crane reeling drums.
Use Spreader Reel CableConstruction
Shown: 1.8/3 kV IEC / 2000V UL RHW-2 LSOH (IEC 60502-1 (1.8/3 kV) & UL 44 RHW-2 / UL 2277 (2,000 V) Dual-Standard Wind Specification) featuring class 5 annealed fine copper (25-400 mm²), hepr / epr dual-standard dielectric and black lsoh thermoset elastomer jacket (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 Annealed Fine Copper (25-400 mm² | IEC 60228 Class 5 flexible plain copper single-core conductor |
| 2 | HEPR / EPR Dual-Standard Dielectric | Certified to both IEC 1.8/3 (3.6) kV and UL RHW-2 2,000 V |
| 3 | Black LSOH Thermoset Elastomer Jacket | Low-smoke zero-halogen flame- and torsion-resistant outer sheath |
Built to IEC 60502-1 (1.8/3 kV) & UL 44 RHW-2 / UL 2277 (2,000 V) Dual-Standard Wind Specification with class 5 annealed fine copper (25-400 mm²) and black lsoh thermoset elastomer jacket
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to IEC 60502-1 (1.8/3 kV) & UL 44 RHW-2 / UL 2277 (2,000 V) Dual-Standard Wind Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 1.8/3 kV IEC / 2000V UL RHW-2 LSOH Construction Schedule (−40…+90 °C) | |||||||
| 1.8/3 kV IEC / 2000V U 1×95 / 4G25 Cu | 1 × 95 mm² (or 4G25 mm² / 3/0 AWG) | IEC 60228 Class 5 Flexible Cu/SnCu | 21.6 | 1,080 | 14.2 | 110 | |
| 1.8/3 kV IEC / 2000V U 1×185 / 4G50 Cu | 1 × 185 mm² (or 4G50 mm² / 373 kcmil) | IEC 60228 Class 5 Flexible Cu/SnCu | 27.8 | 1,960 | 27.5 | 140 | |
| 1.8/3 kV IEC / 2000V U 1×300 / 4G95 Cu | 1 × 300 mm² (or 1×535/777 kcmil) | IEC 60228 Class 5 Flexible Cu/SnCu | 34.6 | 3,120 | 45.0 | 175 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 1 × 95 mm² (or 4G25 mm² / 3/0 AWG) | 0.21 | 1.8/3 kV / 2,000 V (320 A Cu) | −40…+90 °C |
| 1 × 185 mm² (or 4G50 mm² / 373 kcmil) | 0.11 | 1.8/3 kV / 2,000 V (495 A Cu) | −40…+90 °C |
| 1 × 300 mm² (or 1×535/777 kcmil) | 0.06 | 1.8/3 kV / 2,000 V (680 A Cu) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (IEC 60502-1 (1.8/3 kV) & UL 44 RHW-2 / UL 2277 (2,000 V) Dual-Standard Wind Specification) | DC resistance at 20 °C and insulation/sheath wall thickness within IEC 60502-1 (1.8/3 kV) & UL 44 RHW-2 / UL 2277 (2,000 V) Dual-Standard Wind Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (IEC 60502-1 (1.8/3 kV) & UL 44 RHW-2 / UL 2277 (2,000 V) Dual-Standard Wind Specification) | Zero dielectric breakdown and verified insulation resistance for 1.8/3 kV / 2,000 V rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (IEC 60502-1 (1.8/3 kV) & UL 44 RHW-2 / UL 2277 (2,000 V) Dual-Standard Wind Specification) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.