halogen-free wind turbine torsion & tower cableEN 50525-2-21 / IEC 60502-10.6/1 kV (-40 to +90 °C)5GM5 HF-EVA Halogen-Free Outer Sheat

CU/EPR/HFEVA 0.6/1 kV (Umax 1.2 kV) Unscreened LSZH Wind Turbine Drip-Loop Torsion CableEN 50525-2-21 / IEC 60502-1 — 0.6/1 kV — -40 to +90 °C Wind Turbine Cable

CU/EPR/HFEVA 0.6/1 kV (Umax 1.2 kV) Unscreened LSZH Wind Turbine Drip-Loop Torsion Cable (EN 50525-2-21 / IEC 60502-1) engineered for 0.6/1 kV wind turbine service across -40 to +90 °C (min. bend radius 5 × OD).

Anti-torsion braid
Flame-retardant
Oil-resistant
Approved
Order designation
CU/EPR/HFEVA 0.6/1 kV 1×95 / 4G25 Cu
Outer Ø ≈
21.6 mm
Net weight ≈
1,080 kg/km
Max. pulling ≈
14.2 kN
Core / stranding
IEC 60228 Class 5 Flexible Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per EN 50525-2-21 / IEC 60502-1
Operating temp.
−40…+90 °C
Cold-climate & nacelle wind service
Min. bend radius
5 × OD
Drip-loop, hub & tower routing
Core / conductor
Class 5 Flexible
EN 60228 Class 5 finely stranded plain c
Outer protection
5GM5 HF-EVA Halo
Low-smoke zero-halogen thermoset EVA jac
Standard
EN 50525-2-21 /
EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind

Typical values for this cable type, based on EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is CU/EPR/HFEVA 0.6/1 kV right for your machine?

CU/EPR/HFEVA 0.6/1 kV (Umax 1.2 kV) Unscreened LSZH Wind Turbine Drip-Loop Torsion Cable (EN 50525-2-21 / IEC 60502-1) engineered for 0.6/1 kV wind turbine service across -40 to +90 °C (min. bend radius 5 × OD).

Free-hanging vertical run

Suitable

Cross-linked EPR/HEPR insulation and 5GM5 / XL-EVA halogen-free jacket withstand ±100°/m to ±180°/m yaw drip-loop torsion at −40 °C.

Fixed installation

Suitable

IEC 60332-3 flame-retardant low-smoke zero-halogen (LSZH) outer sheath routes safely through vertical wind tower ladders and cleats.

Offshore platform & shipboard deck trays

Suitable

Oil-, ozone-, UV- and salt-mist-resistant thermoset EVA/elastomer sheath endures both onshore and offshore wind nacelle environments.

Motor stator, traction & converter leads

Suitable

Finely stranded IEC 60228 Class 5 copper or AA8000 Al-alloy conductors terminate cleanly into generator, converter and transformer lugs.

Motorised monospiral reel

Not suitable

Wind turbine drip-loop torsion and fixed tower cables are not designed for high-speed horizontal crane reeling drums.

Use Spreader Reel Cable
Typical machinesRenewable Energy & EV ChargingOnshore & Offshore Wind Turbine Nacelle Drip LoopsWind Turbine Generator-to-Converter Main Power DropsHalogen-Free Wind Tower Vertical Power DistributionCold-Climate (−40 °C) Renewable Energy Installations

Construction

Layer by layer

Shown: CU/EPR/HFEVA 0.6/1 kV (EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification) featuring class 5 flexible bare copper (3-5 cores, 1.5-95 mm²), 3gi3 epr core insulation (0.6/1 kv) and 5gm5 hf-eva halogen-free outer sheath (±144°/m) (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 5 Flexible Bare Copper (3-5 Cores,EN 60228 Class 5 finely stranded plain copper conductors
23GI3 EPR Core Insulation (0.6/1 kV)Ethylene-propylene rubber coded Brown, Black, Grey, Green/Yellow
35GM5 HF-EVA Halogen-Free Outer Sheath (±Low-smoke zero-halogen thermoset EVA jacket for yaw drip loops

CU/EPR/HFEVA 0.6/1 kV — Standard Wind Turbine Execution

Built to EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification with class 5 flexible bare copper (3-5 cores, 1.5-95 mm²) and 5gm5 hf-eva halogen-free outer sheath (±144°/m)

CU/EPR/HFEVA 0.6/1 kV — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

CU/EPR/HFEVA 0.6/1 kV — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
0.6/1 kV (EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification)
Core / conductor construction
Class 5 Flexible Bare Copper (3-5 Cores, 1.5-95 mm²) — EN 60228 Class 5 finely stranded plain copper conductors
Primary dielectric / insulation
3GI3 EPR Core Insulation (0.6/1 kV) — Ethylene-propylene rubber coded Brown, Black, Grey, Green/Yellow

Thermal

Continuous operating temperature
−40…+90 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −40…+90 °C per EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
5GM5 HF-EVA Halogen-Free Outer Sheath (±144°/m) — Low-smoke zero-halogen thermoset EVA jacket for yaw drip loops
Minimum bending radius
5 × OD
Intermediate screen / separator / core layer
3GI3 EPR Core Insulation (0.6/1 kV) — Ethylene-propylene rubber coded Brown, Black, Grey, Green/Yellow

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
CU/EPR/HFEVA 0.6/1 kV
Sheath colour & metre marking
Continuous metre-marked black outer finish (5GM5 HF-EVA Halo)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard CU/EPR/HFEVA 0.6/1 kV wind turbine configurations

Manufactured to EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
CU/EPR/HFEVA 0.6/1 kV Construction Schedule (−40…+90 °C)
CU/EPR/HFEVA 0.6/1 kV 1×95 / 4G25 Cu1 × 95 mm² (or 4G25 mm² / 3/0 AWG)IEC 60228 Class 5 Flexible Cu/SnCu21.61,08014.2110
CU/EPR/HFEVA 0.6/1 kV 1×185 / 4G50 Cu1 × 185 mm² (or 4G50 mm² / 373 kcmil)IEC 60228 Class 5 Flexible Cu/SnCu27.81,96027.5140
CU/EPR/HFEVA 0.6/1 kV 1×300 / 4G95 Cu1 × 300 mm² (or 1×535/777 kcmil)IEC 60228 Class 5 Flexible Cu/SnCu34.63,12045.0175
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification)DC resistance at 20 °C and insulation/sheath wall thickness within EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

EN 50525-2-21 / IEC 60502-1 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX CU/EPR/HFEVA 0.6/1 kV EN 50525-2-21 / IEC 60502-1 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define CU/EPR/HFEVA 0.6/1 kV (CU/EPR/HFEVA 0.6/1 kV (Umax 1.2 kV) Unscreened LSZH Wind Turbine Drip-Loop Torsion Cable)?
CU/EPR/HFEVA 0.6/1 kV (CU/EPR/HFEVA 0.6/1 kV (Umax 1.2 kV) Unscreened LSZH Wind Turbine Drip-Loop Torsion Cable) is manufactured in accordance with EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification for 0.6/1 kV wind turbine service over -40 to +90 °C. Its 3-layer construction comprises class 5 flexible bare copper (3-5 cores, 1.5-95 mm²), 3gi3 epr core insulation (0.6/1 kv) and 5gm5 hf-eva halogen-free outer sheath (±144°/m).
What is the minimum bending radius and operating temperature range for CU/EPR/HFEVA 0.6/1 kV?
The minimum bending radius for CU/EPR/HFEVA 0.6/1 kV is 5 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of CU/EPR/HFEVA 0.6/1 kV arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 5 Flexible Bare Copper (3-5 Cores, 1.5-95 mm²) — EN 60228 Class 5 finely stranded plain copper conductors; (02) 3GI3 EPR Core Insulation (0.6/1 kV) — Ethylene-propylene rubber coded Brown, Black, Grey, Green/Yellow; (03) 5GM5 HF-EVA Halogen-Free Outer Sheath (±144°/m) — Low-smoke zero-halogen thermoset EVA jacket for yaw drip loops.
What factory test certificates are supplied with CU/EPR/HFEVA 0.6/1 kV?
Every production drum of CU/EPR/HFEVA 0.6/1 kV undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per EN 50525-2-21 / VDE 0207 3GI3/5GM5 Wind Drip-Loop Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for CU/EPR/HFEVA 0.6/1 kV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

CU/EPR/HFEVA 0.6/1 kV (Umax 1.2 kV) Unscreened LSZH Wind Turbine Drip-Loop Torsion Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote