29528 Series 600/1000V TC-ER WTTC Dual Copper-Tape VFD CableUL 1277 TC-ER 600 V / UL 2277 WTTC 1,000 V (-40 to +90 °C) 3-phase + 3 symmetrical split grounds XLPE insulated and dual helical copper-tape shielded high-power VFD feeder.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

EMC screen
Low-EMC design
Oil-resistant
Flame-retardant
Order designation
29528 3×1 AWG + 3×6 AWG Sym. GND
Outer diameter
30.5 mm
Cable weight
2,120 kg/km
Min. bend radius
366 mm
Conductor & shield
7×19×22 Tinned Cu + 1.45mm XLPE + Dual Helical Cu Tape
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600/1,000 V
UL 1277 TC-ER / UL 2277 WTTC
Temperature
−40…+90 °C
Fixed / flex duty
Min. bend radius
12 × OD
30.5–46.7 mm
Screening
Dual Cu Tape
100% dual helical bare Cu tape
Outer sheath
Industrial PVC
Oil & sunlight resistant
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per UL 1277 TC-ER / UL 2277 WTTC (29528 Series 600/1000V TC-ER WTTC) — confirmed in the datasheet and quotation for your order.

Application fit

Is 29528 Series 600/1000V TC-ER WTTC right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for open cable tray, raceway and supported industrial runs per standard installation rules.

VFD inverter to AC motor screened feeder

Suitable

Low-impedance shielding contains high-frequency common-mode currents and dV/dt voltage spikes.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

Offshore platform & shipboard deck trays

Suitable

Outer sheath compound resists industrial cutting fluids, mineral oils and outdoor sunlight.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Wind turbine tower & nacelle

Suitable

Cold-flex and torsion-tested 000 V XLPE construction supports wind turbine tower risers, yaw loops, and nacelle switchgear.

Typical machinesRenewable Energy & EV ChargingIndustrial automation & control cabinetsInverter-fed motor drive systemsProcess instrumentation & oil/gas skidsMachine tools & robotic cellsData centers, stadiums & broadcast facilities

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

29528 Series 600/1000V TC-ER WTTC – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
13×1 AWG (7×19×22) Tinned Copper Phases3×1 AWG (42.4 mm²) Class D Stranded Tinned Copper Phases
21.45mm XLPE + 3×6 AWG Symmetrical GroundsXLPE Phase Insulation + 3×6 AWG (7×19×27) Bare Cu Grounds
3Two Overlapping Helical Bare Copper Tape Shields100% Coverage Dual Helical Bare Copper Tape Screen
4Sunlight & Oil Resistant Black PVC JacketUL 1277 TC-ER / 1000V WTTC Heavy-Duty Outer Sheath (30.48 mm OD)

3 × 42.4 mm² (7×19×22) + 3 × 13.3 mm² GND

7×19×22 Tinned Cu + 1.45mm XLPE + Dual Helical Cu Tape · Outer diameter 30.48 mm.

3 × 33.6 mm² + 3 × 8.37 mm² GND

Stranded Tinned Cu + 1.45mm XLPE + Dual Helical Cu Tape · Outer diameter 28.45 mm.

3 × 107.2 mm² + 3 × 21.2 mm² GND

Stranded Tinned Cu + XLPE + Dual Helical Cu Tape · Outer diameter 46.74 mm.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per UL 1277 TC-ER / UL 2277 WTTC (29528 Series 600/1000V TC-ER WTTC). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
600 V TC-ER / 1,000 V WTTC
Conductor & core insulation
3×1 AWG (42.4 mm²) Class D Stranded Tinned Copper Phases · XLPE Phase Insulation + 3×6 AWG (7×19×27) Bare Cu Grounds
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
−40…+90 °C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
UL 1277 TC-ER / UL 2277 WTTC

Mechanical

Minimum bending radius
12 × OD
Screening / armour architecture
100% Coverage Dual Helical Bare Copper Tape Screen
Outer sheath material & colour
UL 1277 TC-ER / 1000V WTTC Heavy-Duty Outer Sheath (30.48 mm OD)

Reference standards

Reference standard
UL 1277 TC-ER / UL 2277 WTTC / CSA C22.2 No. 230 CIC-TC / NFPA 79 / IEEE 1202
Hazardous Substance Compliance
CE, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
29528 Series 600/1000V TC-ER WTTC
3 × 42.4 mm² (7×19×22) + 3 × 13.3 mm² GND7×19×22 Tinned Cu + 1.45mm XLPE + Dual Helical Cu TapeXLPE Phase Insulation + 3×6 AWG (7×19×27) Bare Cu GroundsIndustrial PVC30.53660.411,685.02,120600 V TC-ER / 1,000 V WTTC (145 A VFD)29528 3×1 AWG + 3×6 AWG Sym. GND
3 × 33.6 mm² + 3 × 8.37 mm² GNDStranded Tinned Cu + 1.45mm XLPE + Dual Helical Cu TapeXLPE Phase Insulation + 3×6 AWG (7×19×27) Bare Cu GroundsIndustrial PVC28.53410.521,340.01,785600 V TC-ER / 1,000 V WTTC (130 A VFD)29527 3×2 AWG + 3×8 AWG Sym. GND
3 × 107.2 mm² + 3 × 21.2 mm² GNDStranded Tinned Cu + XLPE + Dual Helical Cu TapeXLPE Phase Insulation + 3×6 AWG (7×19×27) Bare Cu GroundsIndustrial PVC46.75610.163,860.04,890600 V TC-ER / 1,000 V WTTC (260 A VFD)29532 3×4/0 AWG + 3×4 AWG Sym. GND
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °CEvery manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation or shieldEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing within standard char limitType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 1277 TC-ER / UL 2277 WTTC CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 29528 SERIES 600/1000V TC-ER WTTC UL 1277 TC-ER / UL 2277 WTTC 600 V TC-ER / 1,000 V WTTC CE ROHS — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
305 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-03
Updated
2026-11-03

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is 29528 Series 600/1000V TC-ER WTTC designed for?
29528 Series 600/1000V TC-ER WTTC is engineered for industrial installations under UL 1277 TC-ER / UL 2277 WTTC, operating over −40…+90 °C with a minimum bending radius of 12 × OD.
How does the construction of 29528 Series 600/1000V TC-ER WTTC protect signal and power integrity?
Its multi-layer build combines 3×1 AWG (7×19×22) Tinned Copper Phases with 1.45mm XLPE + 3×6 AWG Symmetrical Grounds and Sunlight & Oil Resistant Black PVC Jacket to ensure mechanical stability and electrical performance.
What standards and fire ratings apply to 29528 Series 600/1000V TC-ER WTTC?
The cable is qualified to UL 1277 TC-ER / UL 2277 WTTC / CSA C22.2 No. 230 CIC-TC / NFPA 79 / IEEE 1202, meeting vertical flame propagation and industrial jacket durability requirements.
Can 29528 Series 600/1000V TC-ER WTTC be supplied in custom lengths or configurations?
Yes. Standard configurations include 29528 3×1 AWG + 3×6 AWG Sym. GND, 29527 3×2 AWG + 3×8 AWG Sym. GND and 29532 3×4/0 AWG + 3×4 AWG Sym. GND, supplied on 305 m, 500 m or 1,000 m export drums.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for 29528 Series 600/1000V TC-ER WTTC

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

29528 Series 600/1000V TC-ER WTTC Dual Copper-Tape VFD Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote