Fixed installation
Approved for open cable tray, raceway and supported industrial runs per standard installation rules.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per UL 1277 TC-ER / UL 2277 WTTC (29528 Series 600/1000V TC-ER WTTC) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for open cable tray, raceway and supported industrial runs per standard installation rules.
Low-impedance shielding contains high-frequency common-mode currents and dV/dt voltage spikes.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Outer sheath compound resists industrial cutting fluids, mineral oils and outdoor sunlight.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use TRA 0.6/1 kV PUR Reeling CableCold-flex and torsion-tested 000 V XLPE construction supports wind turbine tower risers, yaw loops, and nacelle switchgear.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | 3×1 AWG (7×19×22) Tinned Copper Phases | 3×1 AWG (42.4 mm²) Class D Stranded Tinned Copper Phases |
| 2 | 1.45mm XLPE + 3×6 AWG Symmetrical Grounds | XLPE Phase Insulation + 3×6 AWG (7×19×27) Bare Cu Grounds |
| 3 | Two Overlapping Helical Bare Copper Tape Shields | 100% Coverage Dual Helical Bare Copper Tape Screen |
| 4 | Sunlight & Oil Resistant Black PVC Jacket | UL 1277 TC-ER / 1000V WTTC Heavy-Duty Outer Sheath (30.48 mm OD) |
7×19×22 Tinned Cu + 1.45mm XLPE + Dual Helical Cu Tape · Outer diameter 30.48 mm.
Stranded Tinned Cu + 1.45mm XLPE + Dual Helical Cu Tape · Outer diameter 28.45 mm.
Stranded Tinned Cu + XLPE + Dual Helical Cu Tape · Outer diameter 46.74 mm.
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Copper weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 29528 Series 600/1000V TC-ER WTTC | |||||||||||
| 3 × 42.4 mm² (7×19×22) + 3 × 13.3 mm² GND | 7×19×22 Tinned Cu + 1.45mm XLPE + Dual Helical Cu Tape | XLPE Phase Insulation + 3×6 AWG (7×19×27) Bare Cu Grounds | Industrial PVC | 30.5 | 366 | 0.41 | 1,685.0 | 2,120 | 600 V TC-ER / 1,000 V WTTC (145 A VFD) | 29528 3×1 AWG + 3×6 AWG Sym. GND | |
| 3 × 33.6 mm² + 3 × 8.37 mm² GND | Stranded Tinned Cu + 1.45mm XLPE + Dual Helical Cu Tape | XLPE Phase Insulation + 3×6 AWG (7×19×27) Bare Cu Grounds | Industrial PVC | 28.5 | 341 | 0.52 | 1,340.0 | 1,785 | 600 V TC-ER / 1,000 V WTTC (130 A VFD) | 29527 3×2 AWG + 3×8 AWG Sym. GND | |
| 3 × 107.2 mm² + 3 × 21.2 mm² GND | Stranded Tinned Cu + XLPE + Dual Helical Cu Tape | XLPE Phase Insulation + 3×6 AWG (7×19×27) Bare Cu Grounds | Industrial PVC | 46.7 | 561 | 0.16 | 3,860.0 | 4,890 | 600 V TC-ER / 1,000 V WTTC (260 A VFD) | 29532 3×4/0 AWG + 3×4 AWG Sym. GND | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation or shield | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing within standard char limit | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.