Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
REF 59986 (1,000 V 3×1 mm² XLPE Foil-Shielded Underwater Projector Cable) & REF 55753 (75-Ohm Coax + 2×2×0.34 mm² Shielded Pairs + 2×1 mm² PUR Video/Lighting Cable) (IEC 60332-1 / Subsea TV, 0.6/1 kV, -25 °C to +75 °C).
Typical values for this cable type, based on IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard — confirmed in the datasheet and quotation for your order.
Application fit
REF 59986 (1,000 V 3×1 mm² XLPE Foil-Shielded Underwater Projector Cable) & REF 55753 (75-Ohm Coax + 2×2×0.34 mm² Shielded Pairs + 2×1 mm² PUR Video/Lighting Cable) (IEC 60332-1 / Subsea TV, 0.6/1 kV, -25 °C to +75 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: REF 59986 & REF 55753 (IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard) featuring 75 ω video coaxial unit (80 pf/m), foil-shielded sensor pairs (2×2×0.34 mm²) and flame-retardant pur sheath (ø8.5–9.0 mm) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | 75 Ω Video Coaxial Unit (80 pF/m) | 75-ohm video coaxial core (0.35 dB/m @ 200 MHz) for underwater TV camera |
| 2 | Foil-Shielded Sensor Pairs (2×2×0.34 mm²) | Extra-flexible tinned copper + polyester elastomer + individual Al/PET foil & drain |
| 3 | Projector Power Cores (2×1.0 / 3×1.0 mm²) | 2×1.0 mm² 600 V plain Cu (REF 55753) or 3×1.0 mm² 1,000 V XLPE tinned Cu (REF 59986) |
| 4 | Flame-Retardant PUR Sheath (Ø8.5–9.0 mm) | Black watertight polyurethane outer sheath compliant with IEC 60332-1 (0.11 kg/m) |
Built to IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard with 75 ω video coaxial unit (80 pf/m) and flame-retardant pur sheath (ø8.5–9.0 mm)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| REF 59986 & REF 55753 Construction Schedule (−25…+75 °C) | |||||||
| REF 59986 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| REF 59986 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| REF 59986 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −25…+75 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −25…+75 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −25…+75 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard) | Verified submersion integrity, tensile load and thermal stability across −25…+75 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.