Contact
Subsea 1,000 V projector & 75 Ω TV camera video/lighting cable1,000 V XLPE & 75 Ω Coax0.35 dB/m @ 200 MHzWatertight FR-PUR

REF 59986 & REF 55753 1,000 V / 600 V Underwater Projector & Video CabIEC 60332-1 / Subsea TV · 0.6/1 kV · Subsea 1,000 v projector & 75 ω tv camera

REF 59986 (1,000 V 3×1 mm² XLPE Foil-Shielded Underwater Projector Cable) & REF 55753 (75-Ohm Coax + 2×2×0.34 mm² Shielded Pairs + 2×1 mm² PUR Video/Lighting Cable) (IEC 60332-1 / Subsea TV, 0.6/1 kV, -25 °C to +75 °C).

Water-resistant
EMC screen
Flame-retardant
Oil-resistant
Order designation
REF 59986 Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per IEC 60332-1 / Subsea TV
Operating temp.
−25…+75 °C
Continuous subsea & marine service
Min. bend radius
8 × OD
Dynamic sheave & fixed routing
Core / conductor
75 Ω Coax + 2×2
75 Ω video coax + 250 V pairs
Outer protection
FR Black PUR
IEC 60332-1 flame-retardant watertight
Standard
IEC 60332-1
IEC 60332-1

Typical values for this cable type, based on IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is REF 59986 & REF 55753 right for your machine?

REF 59986 (1,000 V 3×1 mm² XLPE Foil-Shielded Underwater Projector Cable) & REF 55753 (75-Ohm Coax + 2×2×0.34 mm² Shielded Pairs + 2×1 mm² PUR Video/Lighting Cable) (IEC 60332-1 / Subsea TV, 0.6/1 kV, -25 °C to +75 °C).

Immersion & wet locations

Suitable

Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.

Vertical / spreader reel

Suitable

Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.

Offshore platform & shipboard deck trays

Suitable

Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.

Trailing & towing

Suitable

High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.

Energy chain / drag chain

Not suitable

Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableWork-Class & Observation ROV SystemsOffshore Wind & Subsea Power GridsOceanographic, Sonar & Seismic SurveyCommercial Diving & Subsea Intervention

Construction

Layer by layer

Shown: REF 59986 & REF 55753 (IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard) featuring 75 ω video coaxial unit (80 pf/m), foil-shielded sensor pairs (2×2×0.34 mm²) and flame-retardant pur sheath (ø8.5–9.0 mm) (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
175 Ω Video Coaxial Unit (80 pF/m)75-ohm video coaxial core (0.35 dB/m @ 200 MHz) for underwater TV camera
2Foil-Shielded Sensor Pairs (2×2×0.34 mm²)Extra-flexible tinned copper + polyester elastomer + individual Al/PET foil & drain
3Projector Power Cores (2×1.0 / 3×1.0 mm²)2×1.0 mm² 600 V plain Cu (REF 55753) or 3×1.0 mm² 1,000 V XLPE tinned Cu (REF 59986)
4Flame-Retardant PUR Sheath (Ø8.5–9.0 mm)Black watertight polyurethane outer sheath compliant with IEC 60332-1 (0.11 kg/m)

REF 59986 & REF 55753 — Standard Subsea & Marine Execution

Built to IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard with 75 ω video coaxial unit (80 pf/m) and flame-retardant pur sheath (ø8.5–9.0 mm)

REF 59986 & REF 55753 — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

REF 59986 & REF 55753 — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard)
Core / conductor construction
75 Ω Video Coaxial Unit (80 pF/m) — 75-ohm video coaxial core (0.35 dB/m @ 200 MHz) for underwater TV camera
Primary dielectric / buffering
Foil-Shielded Sensor Pairs (2×2×0.34 mm²) — Extra-flexible tinned copper + polyester elastomer + individual Al/PET foil & drain

Thermal

Continuous operating temperature
−25…+75 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Flame-Retardant PUR Sheath (Ø8.5–9.0 mm) — Black watertight polyurethane outer sheath compliant with IEC 60332-1 (0.11 kg/m)
Minimum bending radius
8 × OD
Hydrostatic, tensile & crush duty
Projector Power Cores (2×1.0 / 3×1.0 mm²) — 2×1.0 mm² 600 V plain Cu (REF 55753) or 3×1.0 mm² 1,000 V XLPE tinned Cu (REF 59986)

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
REF 59986 & REF 55753
Sheath colour & metre marking
Continuous metre-marked black outer finish (FR Black PUR (Ø8.5–9mm))
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard REF 59986 & REF 55753 subsea & marine configurations

Manufactured to IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
REF 59986 & REF 55753 Construction Schedule (−25…+75 °C)
REF 59986 Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
REF 59986 Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
REF 59986 Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard)DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard)Verified submersion integrity, tensile load and thermal stability across −25…+75 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60332-1 / Subsea TV CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX REF 59986 & REF 55753 IEC 60332-1 / Subsea TV 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define REF 59986 & REF 55753 (REF 59986 & REF 55753 1,000 V / 600 V Underwater Projector & Video Cable)?
REF 59986 & REF 55753 (REF 59986 & REF 55753 1,000 V / 600 V Underwater Projector & Video Cable) is manufactured in accordance with IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard for 0.6/1 kV service over -25 °C to +75 °C. Its 4-layer construction comprises 75 ω video coaxial unit (80 pf/m), foil-shielded sensor pairs (2×2×0.34 mm²) and flame-retardant pur sheath (ø8.5–9.0 mm).
What is the minimum bending radius and operating temperature range for REF 59986 & REF 55753?
The minimum bending radius for REF 59986 & REF 55753 is 8 × OD across its continuous operating temperature range of -25 °C to +75 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of REF 59986 & REF 55753 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) 75 Ω Video Coaxial Unit (80 pF/m) — 75-ohm video coaxial core (0.35 dB/m @ 200 MHz) for underwater TV camera; (02) Foil-Shielded Sensor Pairs (2×2×0.34 mm²) — Extra-flexible tinned copper + polyester elastomer + individual Al/PET foil & drain; (03) Projector Power Cores (2×1.0 / 3×1.0 mm²) — 2×1.0 mm² 600 V plain Cu (REF 55753) or 3×1.0 mm² 1,000 V XLPE tinned Cu (REF 59986); (04) Flame-Retardant PUR Sheath (Ø8.5–9.0 mm) — Black watertight polyurethane outer sheath compliant with IEC 60332-1 (0.11 kg/m).
What factory test certificates are supplied with REF 59986 & REF 55753?
Every production drum of REF 59986 & REF 55753 undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per IEC 60332-1 / Subsea 75 Ω Video & 1,000 V Projector Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for REF 59986 & REF 55753

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

REF 59986 & REF 55753 1,000 V / 600 V Underwater Projector & Video Cab

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote