Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
REF 58400 2-Inch Armoured Stainless-Steel Core Tube with Contra-Helical Double Aramid Braid & Galvanized Steel Wire Armour (57,000 daN) PUR Subsea Gas-Extraction Umbilical (57,000 daN Subsea Riser, 0.6/1 kV, -20 °C to +70 °C).
Typical values for this cable type, based on ISO 13628-5 / 57,000 daN Armoured Subsea Gas-Extraction Riser — confirmed in the datasheet and quotation for your order.
Application fit
REF 58400 2-Inch Armoured Stainless-Steel Core Tube with Contra-Helical Double Aramid Braid & Galvanized Steel Wire Armour (57,000 daN) PUR Subsea Gas-Extraction Umbilical (57,000 daN Subsea Riser, 0.6/1 kV, -20 °C to +70 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: REF 58400 (ISO 13628-5 / 57,000 daN Armoured Subsea Gas-Extraction Riser) featuring 2" armored stainless-steel core hose, contra-helical double aramid braid and polyurethane outer sheath (ø84 ± 2 mm) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | 2" Armored Stainless-Steel Core Hose | Central 2-inch (50.8 mm bore) armored stainless-steel hose for subsea methane extraction |
| 2 | Contra-Helical Double Aramid Braid | Two counter-helical layers of high-modulus aramid fibre tensile reinforcement |
| 3 | Galvanized Steel Wire Armor (≥57,000 daN) | 44 helically served galvanized round steel wires for crush & impact protection |
| 4 | Polyurethane Outer Sheath (Ø84 ± 2 mm) | Heavy-duty black PUR jacket (7.0 kg/m, equipped with SS anchor & PU bend limiter) |
Built to ISO 13628-5 / 57,000 daN Armoured Subsea Gas-Extraction Riser with 2" armored stainless-steel core hose and polyurethane outer sheath (ø84 ± 2 mm)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to ISO 13628-5 / 57,000 daN Armoured Subsea Gas-Extraction Riser for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| REF 58400 Construction Schedule (−20…+70 °C) | |||||||
| REF 58400 3-Part / Compact Assembly | Gas/Hydraulic Hose + Power + Comms/Coax | Helical cabled composite umbilical | 28.5 | 920 | 25.0 | 285 | |
| REF 58400 4-Part / Standard Assembly | Dual Hose + 75 Ω Video Coax + Comms Pairs | Helical cabled composite umbilical | 36.0 | 1,540 | 48.0 | 360 | |
| REF 58400 Heavy Bell / Intervention | Multi-Hose + 3×Coax + Power/Signal Quads | Aramid-reinforced subsea umbilical | 54.0 | 3,420 | 90.0 | 540 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| Gas/Hydraulic Hose + Power + Comms/Coax | 4.95 | 0.6/1 kV + 35–240 bar Fluid | −20…+70 °C |
| Dual Hose + 75 Ω Video Coax + Comms Pairs | 3.30 | 0.6/1 kV + 35–240 bar Fluid | −20…+70 °C |
| Multi-Hose + 3×Coax + Power/Signal Quads | 1.91 | 0.6/1 kV + 100–240 bar Fluid | −20…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ISO 13628-5 / 57,000 daN Armoured Subsea Gas-Extraction Riser) | DC resistance at 20 °C / optical attenuation and outer diameter within ISO 13628-5 / 57,000 daN Armoured Subsea Gas-Extraction Riser tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ISO 13628-5 / 57,000 daN Armoured Subsea Gas-Extraction Riser) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (ISO 13628-5 / 57,000 daN Armoured Subsea Gas-Extraction Riser) | Verified submersion integrity, tensile load and thermal stability across −20…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.