Contact

3079A 150 Ohm 22 AWG PROFIBUS DP PLTC Shielded Fieldbus CableIEC 61158-2 / UL 13 PLTC / CMG (150 Ω, 300 V, -30 to +75 °C) 1-pair 22 AWG solid bare copper foil and 65% tinned copper braid shielded PROFIBUS DP fieldbus cable.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

EMC screen
Low-EMC design
Oil-resistant
Flame-retardant
Order designation
3079A 1 Pair × 22 AWG Solid BC (150 Ω)
Outer diameter
8.0 mm
Cable weight
76 kg/km
Min. bend radius
80 mm
Conductor & shield
Solid Bare Cu + Foam-Skin PE + Foil/65% TCWB
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Impedance
150 Ω
3–20 MHz fieldbus
Temperature
−30…+75 °C
Fixed / flex duty
Min. bend radius
10 × OD
8.0–13.8 mm
Screening
Foil + TC Braid
360° foil + tinned Cu braid
Outer sheath
Industrial PVC
Oil & sunlight resistant
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per IEC 61158-2 PROFIBUS DP / UL 13 PLTC (3079A 150Ω PROFIBUS DP PLTC) — confirmed in the datasheet and quotation for your order.

Application fit

Is 3079A 150Ω PROFIBUS DP PLTC right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for open cable tray, raceway and supported industrial runs per standard installation rules.

Switchgear & control cabinet wiring

Suitable

Controlled characteristic impedance and low mutual capacitance preserve signal eye opening over long trunks.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

Offshore platform & shipboard deck trays

Suitable

Outer sheath compound resists industrial cutting fluids, mineral oils and outdoor sunlight.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Industrial network, bus & patch rack

Suitable

Controlled-impedance PE/PVC construction delivers low-attenuation telemetry across industrial Ethernet, fieldbus, and control racks.

Typical machinesOil & Gas CableIndustrial automation & control cabinetsInverter-fed motor drive systemsProcess instrumentation & oil/gas skidsMachine tools & robotic cellsData centers, stadiums & broadcast facilities

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

3079A 150Ω PROFIBUS DP PLTC – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
11 Pair 22 AWG Solid Bare Copper0.64 mm Solid Bare Copper Conductors (1 Pair)
2Foam-Skin Polyethylene InsulationRed & Green Color-Coded Low-Loss Foam-Skin PE
3100% Aluminum/Polyester Foil + Drain WireZ-Fold Foil Shield + 22 AWG Tinned Copper Drain
465% Tinned Copper Wire Braid ShieldOverall Braided Tinned Copper EMC Screen
5Sunlight & Oil Resistant Violet PVC JacketUL PLTC / CMG Violet PVC Outer Sheath (8.00 mm OD)

1 × 2 × 22 AWG (0.64 mm Solid BC)

Solid Bare Cu + Foam-Skin PE + Foil/65% TCWB · Outer diameter 8 mm.

1 × 2 × 22 AWG (7×30 AWG Stranded)

7×30 AWG Bare Cu + Foam PE + Foil/65% TCWB · Outer diameter 8.1 mm.

1 × 2 × 22 AWG + Aluminum Interlocked Armor

Solid Bare Cu + Foam PE + Foil/TCWB + AIA · Outer diameter 13.8 mm.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per IEC 61158-2 PROFIBUS DP / UL 13 PLTC (3079A 150Ω PROFIBUS DP PLTC). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
300 V
Conductor & core insulation
0.64 mm Solid Bare Copper Conductors (1 Pair) · Red & Green Color-Coded Low-Loss Foam-Skin PE
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
−30…+75 °C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
IEC 61158-2 PROFIBUS DP / UL 13 PLTC

Mechanical

Minimum bending radius
10 × OD
Screening / armour architecture
Z-Fold Foil Shield + 22 AWG Tinned Copper Drain · Overall Braided Tinned Copper EMC Screen
Outer sheath material & colour
UL PLTC / CMG Violet PVC Outer Sheath (8.00 mm OD)

Reference standards

Reference standard
IEC 61158-2 / EN 50170 / UL 13 PLTC / UL 444 CMG / CSA CMG FT4
Hazardous Substance Compliance
CE, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
3079A 150Ω PROFIBUS DP PLTC
1 × 2 × 22 AWG (0.64 mm Solid BC)Solid Bare Cu + Foam-Skin PE + Foil/65% TCWBRed & Green Color-Coded Low-Loss Foam-Skin PEIndustrial PVC8.08055.0026.576150 ± 15 Ω (3–20 MHz) · 28.0 pF/m · 12 Mbps3079A 1 Pair × 22 AWG Solid BC (150 Ω)
1 × 2 × 22 AWG (7×30 AWG Stranded)7×30 AWG Bare Cu + Foam PE + Foil/65% TCWBRed & Green Color-Coded Low-Loss Foam-Skin PEIndustrial PVC8.18157.5027.078150 ± 15 Ω (3–20 MHz) · 28.5 pF/m · 12 Mbps3079A-FLEX 1 Pair × 22 AWG (7×30) Stranded
1 × 2 × 22 AWG + Aluminum Interlocked ArmorSolid Bare Cu + Foam PE + Foil/TCWB + AIARed & Green Color-Coded Low-Loss Foam-Skin PEIndustrial PVC13.813855.0026.5195150 ± 15 Ω (3–20 MHz) · 28.0 pF/m · 12 Mbps3079A-AIA 1 Pair × 22 AWG Armored PLTC
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °CEvery manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation or shieldEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing within standard char limitType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 61158-2 PROFIBUS DP / UL 13 PLTC CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 3079A 150Ω PROFIBUS DP PLTC IEC 61158-2 PROFIBUS DP / UL 13 PLTC 300 V CE ROHS — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
305 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-03
Updated
2026-11-03

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is 3079A 150Ω PROFIBUS DP PLTC designed for?
3079A 150Ω PROFIBUS DP PLTC is engineered for industrial installations under IEC 61158-2 PROFIBUS DP / UL 13 PLTC, operating over −30…+75 °C with a minimum bending radius of 10 × OD.
How does the construction of 3079A 150Ω PROFIBUS DP PLTC protect signal and power integrity?
Its multi-layer build combines 1 Pair 22 AWG Solid Bare Copper with Foam-Skin Polyethylene Insulation and Sunlight & Oil Resistant Violet PVC Jacket to ensure mechanical stability and electrical performance.
What standards and fire ratings apply to 3079A 150Ω PROFIBUS DP PLTC?
The cable is qualified to IEC 61158-2 / EN 50170 / UL 13 PLTC / UL 444 CMG / CSA CMG FT4, meeting vertical flame propagation and industrial jacket durability requirements.
Can 3079A 150Ω PROFIBUS DP PLTC be supplied in custom lengths or configurations?
Yes. Standard configurations include 3079A 1 Pair × 22 AWG Solid BC (150 Ω), 3079A-FLEX 1 Pair × 22 AWG (7×30) Stranded and 3079A-AIA 1 Pair × 22 AWG Armored PLTC, supplied on 305 m, 500 m or 1,000 m export drums.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for 3079A 150Ω PROFIBUS DP PLTC

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

3079A 150Ω PROFIBUS DP PLTC 3079A 150 Ohm 22 AWG PROFIBUS DP PLTC Shielded Fieldbus Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote