wind turbine drip-loop, tray & pitch control cableUL AWM 1000V / CSA / VDE600 V / 1,000 V (-40 to +90 °C)Black Oil/Cold/UV Modified PVC Jacke

PVC/PVC UL/CSA 600 V / 1,000 V & VDE Cold-Modified (±150°/m) Torsion-Resistant Wind Control CableUL AWM 1000V / CSA / VDE — 600 V / 1,000 V — -40 to +90 °C Wind Turbine Cable

PVC/PVC UL/CSA 600 V / 1,000 V & VDE Cold-Modified (±150°/m) Torsion-Resistant Wind Control Cable (UL AWM 1000V / CSA / VDE) engineered for 600 V / 1,000 V wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).

Anti-torsion braid
Flame-retardant
Oil-resistant
Approved
Order designation
PVC/PVC UL/CSA 600V/10 7G1.5 mm²
Outer Ø ≈
11.4 mm
Net weight ≈
215 kg/km
Max. pulling ≈
2.4 kN
Core / stranding
IEC 60228 Class 5/6 / Class K Cu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V / 1,000 V
Tested per UL AWM 1000V / CSA / VDE
Operating temp.
−40…+90 °C
Cold-climate & nacelle wind service
Min. bend radius
6 × OD
Drip-loop, hub & tower routing
Core / conductor
Class 5 / Class
Extra-flexible plain copper conductors
Outer protection
Black Oil/Cold/U
Engineered for ±150°/m yaw drip-loop tor
Standard
UL AWM 1000V / C
UL 758 AWM 600 V/1,000 V, CSA C22.2 No.

Typical values for this cable type, based on UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is PVC/PVC UL/CSA 600V/1000V Torsion right for your machine?

PVC/PVC UL/CSA 600 V / 1,000 V & VDE Cold-Modified (±150°/m) Torsion-Resistant Wind Control Cable (UL AWM 1000V / CSA / VDE) engineered for 600 V / 1,000 V wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).

Free-hanging vertical run

Suitable

Class 5, Class 6 and Class K extra-flexible copper cores withstand continuous ±150°/m drip-loop and ±450°/0.5m pitch torsion down to −40/−

Fixed installation

Suitable

UL 2277 WTTC 1,000 V / UL 1277 TC-ER 600 V and IEC 0.6/1 kV ratings allow open tray and Exposed Run routing across the nacelle and tower.

Switchgear & control cabinet wiring

Suitable

Number-coded cores and 85% tinned copper braid / foil+braid shields terminate neatly into pitch servo boxes, slip-rings and PLC cabinets.

Energy chain / drag chain

Suitable

PUR-sheathed Class 6 pitch & slip-ring cables (RT 113/123, RT 114/116) handle combined rotary hub motion and bending.

Vertical / spreader reel

Not suitable

Wind turbine control and tray cable is not engineered for deepwater vertical oceanographic lift winches.

Use A304739 BOP MUX Umbilical
Typical machinesRenewable Energy & EV ChargingWind Turbine Rotor Hub Pitch Control & Slip-RingsNacelle-to-Tower Multi-Core Drip-Loop Control BundlesUL 2277 WTTC / TC-ER Nacelle & Tower Cable TraysBlade De-Icing, Trace Heating & Aviation Obstruction Lights

Construction

Layer by layer

Shown: PVC/PVC UL/CSA 600V/1000V Torsion (UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification) featuring class 5 / class 6 bare copper (2-37 cores, 0.5-70 mm²), cold-modified pvc core insulation (ul/csa & vde) and black oil/cold/uv modified pvc jacket (-40 °c) (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 5 / Class 6 Bare Copper (2-37 CoreExtra-flexible plain copper conductors
2Cold-Modified PVC Core Insulation (UL/CSNumber-coded modified PVC rated 600 V / 1,000 V
3Black Oil/Cold/UV Modified PVC Jacket (-Engineered for ±150°/m yaw drip-loop torsion

PVC/PVC UL/CSA 600V/1000V Torsion — Standard Wind Turbine Execution

Built to UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification with class 5 / class 6 bare copper (2-37 cores, 0.5-70 mm²) and black oil/cold/uv modified pvc jacket (-40 °c)

PVC/PVC UL/CSA 600V/1000V Torsion — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

PVC/PVC UL/CSA 600V/1000V Torsion — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
600 V / 1,000 V (UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification)
Core / conductor construction
Class 5 / Class 6 Bare Copper (2-37 Cores, 0.5-70 mm²) — Extra-flexible plain copper conductors
Primary dielectric / insulation
Cold-Modified PVC Core Insulation (UL/CSA & VDE) — Number-coded modified PVC rated 600 V / 1,000 V

Thermal

Continuous operating temperature
−40…+90 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −40…+90 °C per UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Black Oil/Cold/UV Modified PVC Jacket (-40 °C) — Engineered for ±150°/m yaw drip-loop torsion
Minimum bending radius
6 × OD
Intermediate screen / separator / core layer
Cold-Modified PVC Core Insulation (UL/CSA & VDE) — Number-coded modified PVC rated 600 V / 1,000 V

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
PVC/PVC UL/CSA 600V/1000V Torsion
Sheath colour & metre marking
Continuous metre-marked black outer finish (Black Oil/Cold/U)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard PVC/PVC UL/CSA 600V/1000V Torsion wind turbine configurations

Manufactured to UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
PVC/PVC UL/CSA 600V/1000V Torsion Construction Schedule (−40…+90 °C)
PVC/PVC UL/CSA 600V/10 7G1.5 mm²7G1.5 mm² (or 7C × 16 AWG)IEC 60228 Class 5/6 / Class K Cu11.42152.470
PVC/PVC UL/CSA 600V/10 12G1.5 mm²12G1.5 mm² (or 12C × 16 AWG)IEC 60228 Class 5/6 / Class K Cu14.83454.190
PVC/PVC UL/CSA 600V/10 18G2.5 mm²18G2.5 mm² (or 18C × 14 AWG)IEC 60228 Class 5/6 / Class K Cu19.66809.8120
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification)DC resistance at 20 °C and insulation/sheath wall thickness within UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification)Zero dielectric breakdown and verified insulation resistance for 600 V / 1,000 V ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL AWM 1000V / CSA / VDE CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX PVC/PVC UL/CSA 600V/1000V Torsion UL AWM 1000V / CSA / VDE 600 V / 1,000 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define PVC/PVC UL/CSA 600V/1000V Torsion (PVC/PVC UL/CSA 600 V / 1,000 V & VDE Cold-Modified (±150°/m) Torsion-Resistant Wind Control Cable)?
PVC/PVC UL/CSA 600V/1000V Torsion (PVC/PVC UL/CSA 600 V / 1,000 V & VDE Cold-Modified (±150°/m) Torsion-Resistant Wind Control Cable) is manufactured in accordance with UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification for 600 V / 1,000 V wind turbine service over -40 to +90 °C. Its 3-layer construction comprises class 5 / class 6 bare copper (2-37 cores, 0.5-70 mm²), cold-modified pvc core insulation (ul/csa & vde) and black oil/cold/uv modified pvc jacket (-40 °c).
What is the minimum bending radius and operating temperature range for PVC/PVC UL/CSA 600V/1000V Torsion?
The minimum bending radius for PVC/PVC UL/CSA 600V/1000V Torsion is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of PVC/PVC UL/CSA 600V/1000V Torsion arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 5 / Class 6 Bare Copper (2-37 Cores, 0.5-70 mm²) — Extra-flexible plain copper conductors; (02) Cold-Modified PVC Core Insulation (UL/CSA & VDE) — Number-coded modified PVC rated 600 V / 1,000 V; (03) Black Oil/Cold/UV Modified PVC Jacket (-40 °C) — Engineered for ±150°/m yaw drip-loop torsion.
What factory test certificates are supplied with PVC/PVC UL/CSA 600V/1000V Torsion?
Every production drum of PVC/PVC UL/CSA 600V/1000V Torsion undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for PVC/PVC UL/CSA 600V/1000V Torsion

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

PVC/PVC UL/CSA 600V/1000V Torsion PVC/PVC UL/CSA 600 V / 1,000 V & VDE Cold-Modified (±150°/m) Torsion-Resistant Wind Control Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote