Free-hanging vertical run
Class 5, Class 6 and Class K extra-flexible copper cores withstand continuous ±150°/m drip-loop and ±450°/0.5m pitch torsion down to −40/−
Product
PVC/PVC UL/CSA 600 V / 1,000 V & VDE Cold-Modified (±150°/m) Torsion-Resistant Wind Control Cable (UL AWM 1000V / CSA / VDE) engineered for 600 V / 1,000 V wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification — confirmed in the datasheet and quotation for your order.
Application fit
PVC/PVC UL/CSA 600 V / 1,000 V & VDE Cold-Modified (±150°/m) Torsion-Resistant Wind Control Cable (UL AWM 1000V / CSA / VDE) engineered for 600 V / 1,000 V wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Class 5, Class 6 and Class K extra-flexible copper cores withstand continuous ±150°/m drip-loop and ±450°/0.5m pitch torsion down to −40/−
UL 2277 WTTC 1,000 V / UL 1277 TC-ER 600 V and IEC 0.6/1 kV ratings allow open tray and Exposed Run routing across the nacelle and tower.
Number-coded cores and 85% tinned copper braid / foil+braid shields terminate neatly into pitch servo boxes, slip-rings and PLC cabinets.
PUR-sheathed Class 6 pitch & slip-ring cables (RT 113/123, RT 114/116) handle combined rotary hub motion and bending.
Wind turbine control and tray cable is not engineered for deepwater vertical oceanographic lift winches.
Use A304739 BOP MUX UmbilicalConstruction
Shown: PVC/PVC UL/CSA 600V/1000V Torsion (UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification) featuring class 5 / class 6 bare copper (2-37 cores, 0.5-70 mm²), cold-modified pvc core insulation (ul/csa & vde) and black oil/cold/uv modified pvc jacket (-40 °c) (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 / Class 6 Bare Copper (2-37 Core | Extra-flexible plain copper conductors |
| 2 | Cold-Modified PVC Core Insulation (UL/CS | Number-coded modified PVC rated 600 V / 1,000 V |
| 3 | Black Oil/Cold/UV Modified PVC Jacket (- | Engineered for ±150°/m yaw drip-loop torsion |
Built to UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification with class 5 / class 6 bare copper (2-37 cores, 0.5-70 mm²) and black oil/cold/uv modified pvc jacket (-40 °c)
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| PVC/PVC UL/CSA 600V/1000V Torsion Construction Schedule (−40…+90 °C) | |||||||
| PVC/PVC UL/CSA 600V/10 7G1.5 mm² | 7G1.5 mm² (or 7C × 16 AWG) | IEC 60228 Class 5/6 / Class K Cu | 11.4 | 215 | 2.4 | 70 | |
| PVC/PVC UL/CSA 600V/10 12G1.5 mm² | 12G1.5 mm² (or 12C × 16 AWG) | IEC 60228 Class 5/6 / Class K Cu | 14.8 | 345 | 4.1 | 90 | |
| PVC/PVC UL/CSA 600V/10 18G2.5 mm² | 18G2.5 mm² (or 18C × 14 AWG) | IEC 60228 Class 5/6 / Class K Cu | 19.6 | 680 | 9.8 | 120 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 7G1.5 mm² (or 7C × 16 AWG) | 13.30 | 600 V / 1,000 V (18 A) | −40…+90 °C |
| 12G1.5 mm² (or 12C × 16 AWG) | 13.30 | 600 V / 1,000 V (16 A) | −40…+90 °C |
| 18G2.5 mm² (or 18C × 14 AWG) | 7.98 | 600 V / 1,000 V (24 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification) | DC resistance at 20 °C and insulation/sheath wall thickness within UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification) | Zero dielectric breakdown and verified insulation resistance for 600 V / 1,000 V rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (UL 758 AWM 600 V/1,000 V, CSA C22.2 No. 210 & VDE 0285 Wind Torsion Specification) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.