Contact
Wet-mate 1/0 AWG 250 A power & PTFE/PP multicore control cable600 V – 1,000 V (250 A)PTFE/PP Control & 1/0 AWGWet-Mate Overmoldable

P8C20# & P1C1/0# (250 A) Subsea Multicore & High-Current Wet-Mate CablDoc. 2013012SC Power/Ctrl · 0.6/1 kV · Wet-mate 1/0 awg 250 a power & ptfe/pp

Wet-Mate Unscreened Single-Core 1/0 AWG 250A High-Current Power (P1C1/0#) & PTFE/PP Multicore Control (P8C20# / P22C20#/3C18#) Underwater PUR Connector Cable Family (Doc. 2013012SC Power/Ctrl, 0.6/1 kV, -30 °C to +80 °C).

Water-resistant
Oil-resistant
Outdoor & humid
Ozone, UV & moisture
Order designation
P8C20# Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per Doc. 2013012SC Power/Ctrl
Operating temp.
−30…+80 °C
Continuous subsea & marine service
Min. bend radius
8 × OD
Dynamic sheave & fixed routing
Core / conductor
8–22×20 AWG
Silver/tinned Cu PTFE/PP control
Outer protection
Vulcanizable
1.02–3.00 mm black halogen-free PUR
Standard
Doc. 2013012SC
Subsea Doc. 2013012SC Unscreened

Typical values for this cable type, based on Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power — confirmed in the datasheet and quotation for your order.

Application fit

Is P8C20# & P1C1/0# SERIES right for your machine?

Wet-Mate Unscreened Single-Core 1/0 AWG 250A High-Current Power (P1C1/0#) & PTFE/PP Multicore Control (P8C20# / P22C20#/3C18#) Underwater PUR Connector Cable Family (Doc. 2013012SC Power/Ctrl, 0.6/1 kV, -30 °C to +80 °C).

Immersion & wet locations

Suitable

Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.

Vertical / spreader reel

Suitable

Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.

Offshore platform & shipboard deck trays

Suitable

Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.

Trailing & towing

Suitable

High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.

Energy chain / drag chain

Not suitable

Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableWork-Class & Observation ROV SystemsOffshore Wind & Subsea Power GridsOceanographic, Sonar & Seismic SurveyCommercial Diving & Subsea Intervention

Construction

Layer by layer

Shown: P8C20# & P1C1/0# SERIES (Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power) featuring conductors (8×20 awg / 1×1/0 awg), type e ptfe / pp core insulation and black halogen-free pur jacket (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Conductors (8×20 AWG / 1×1/0 AWG)Silver-plated Cu (P8C20#), tinned Cu (P2C20#–P22C20#) or ≥1000-strand 53.5 mm² Cu (P1C1/0#)
2Type E PTFE / PP Core Insulation600 V Type E PTFE (P8C20#) or polypropylene (PP) color-coded core insulation
3Central Polypropylene Rod FillerExtruded PP center filler rod maintaining circular hydrostatic stability
4Clear Polyester / Non-Woven Binder TapeHelically lapped overall clear Polyester tape (or non-woven barrier on P1C1/0#)
5Black Halogen-Free PUR Jacket1.02–3.00 mm black polyurethane sheath vulcanizable to Wet-Mate connectors

P8C20# & P1C1/0# SERIES — Standard Subsea & Marine Execution

Built to Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power with conductors (8×20 awg / 1×1/0 awg) and black halogen-free pur jacket

P8C20# & P1C1/0# SERIES — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

P8C20# & P1C1/0# SERIES — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power)
Core / conductor construction
Conductors (8×20 AWG / 1×1/0 AWG) — Silver-plated Cu (P8C20#), tinned Cu (P2C20#–P22C20#) or ≥1000-strand 53.5 mm² Cu (P1C1/0#)
Primary dielectric / buffering
Type E PTFE / PP Core Insulation — 600 V Type E PTFE (P8C20#) or polypropylene (PP) color-coded core insulation

Thermal

Continuous operating temperature
−30…+80 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Black Halogen-Free PUR Jacket — 1.02–3.00 mm black polyurethane sheath vulcanizable to Wet-Mate connectors
Minimum bending radius
8 × OD
Hydrostatic, tensile & crush duty
Clear Polyester / Non-Woven Binder Tape — Helically lapped overall clear Polyester tape (or non-woven barrier on P1C1/0#)

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
P8C20# & P1C1/0# SERIES
Sheath colour & metre marking
Continuous metre-marked black outer finish (Vulcanizable Black PUR)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard P8C20# & P1C1/0# SERIES subsea & marine configurations

Manufactured to Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
P8C20# & P1C1/0# SERIES Construction Schedule (−30…+80 °C)
P8C20# Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
P8C20# Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
P8C20# Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power)DC resistance at 20 °C / optical attenuation and outer diameter within Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power)Verified submersion integrity, tensile load and thermal stability across −30…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

Doc. 2013012SC Power/Ctrl CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX P8C20# & P1C1/0# SERIES Doc. 2013012SC Power/Ctrl 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define P8C20# & P1C1/0# SERIES (P8C20# & P1C1/0# (250 A) Subsea Multicore & High-Current Wet-Mate Cable)?
P8C20# & P1C1/0# SERIES (P8C20# & P1C1/0# (250 A) Subsea Multicore & High-Current Wet-Mate Cable) is manufactured in accordance with Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power for 0.6/1 kV service over -30 °C to +80 °C. Its 5-layer construction comprises conductors (8×20 awg / 1×1/0 awg), type e ptfe / pp core insulation and black halogen-free pur jacket.
What is the minimum bending radius and operating temperature range for P8C20# & P1C1/0# SERIES?
The minimum bending radius for P8C20# & P1C1/0# SERIES is 8 × OD across its continuous operating temperature range of -30 °C to +80 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of P8C20# & P1C1/0# SERIES arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Conductors (8×20 AWG / 1×1/0 AWG) — Silver-plated Cu (P8C20#), tinned Cu (P2C20#–P22C20#) or ≥1000-strand 53.5 mm² Cu (P1C1/0#); (02) Type E PTFE / PP Core Insulation — 600 V Type E PTFE (P8C20#) or polypropylene (PP) color-coded core insulation; (03) Central Polypropylene Rod Filler — Extruded PP center filler rod maintaining circular hydrostatic stability; (04) Clear Polyester / Non-Woven Binder Tape — Helically lapped overall clear Polyester tape (or non-woven barrier on P1C1/0#); (05) Black Halogen-Free PUR Jacket — 1.02–3.00 mm black polyurethane sheath vulcanizable to Wet-Mate connectors.
What factory test certificates are supplied with P8C20# & P1C1/0# SERIES?
Every production drum of P8C20# & P1C1/0# SERIES undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per Subsea Doc. 2013012SC Unscreened Multicore & 250 A Power, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for P8C20# & P1C1/0# SERIES

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

P8C20# & P1C1/0# SERIES P8C20# & P1C1/0# (250 A) Subsea Multicore & High-Current Wet-Mate Cabl

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote