Immersion & wet locations
Polyether-based black polyurethane jacket bonds cleanly to neoprene and polyurethane subsea connector overmoulds.
Product
P8C16#OS 600 V overall-screened subsea interconnection cable combining 8 × 16 AWG (1.34 mm²) flexible tinned copper conductors, color-coded PP insulation, fibrillated PP fillers, ≥85% tinned copper braid shield (OS) and a black subsea PUR jacket.
Typical values for this cable type, based on ISO 13628-5 / IEC 60092-350 — confirmed in the datasheet and quotation for your order.
Application fit
P8C16#OS 600 V overall-screened subsea interconnection cable combining 8 × 16 AWG (1.34 mm²) flexible tinned copper conductors, color-coded PP insulation, fibrillated PP fillers, ≥85% tinned copper braid shield (OS) and a black subsea PUR jacket.
Polyether-based black polyurethane jacket bonds cleanly to neoprene and polyurethane subsea connector overmoulds.
Engineered for ROV manipulators, cameras, CTD profilers, subsea valve packs and wet-mateable bulkhead whips.
Flexible stranded tinned copper cores and fibrillated PP fillers maintain circular profile under hydrostatic pressure.
Rated up to +80 °C in air and +60 °C in continuous seawater immersion; not for high-temperature furnaces.
(N)7YRDGOEU-JConstruction
Shown: P8C16#OS (ISO 13628-5 / IEC 60092-350) featuring conductors (8x16 awg / 1.34 mm²), primary core insulation and subsea outer jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductors (8x16 AWG / 1.34 mm²) | Eight 16 AWG (1.34 mm²) flexible stranded electrolytic tinned copper conductors for subsea connector whips and ROV sensorsISO 13628-5 / IEC 60092-350 |
| 2 | Primary Core Insulation | High-insulation-resistance color-coded polypropylene (PP) core insulation (Black, White, Red, Green, Orange, Blue, Yellow, Brown)ISO 13628-5 / IEC 60092-350 |
| 3 | Bedding & Separator Tape | Non-hygroscopic fibrillated polypropylene interstitial fillers wrapped with a clear polyester (PET) binder tapeISO 13628-5 / IEC 60092-350 |
| 4 | Overall Braided Shield (OS) | Overall braided tinned copper electromagnetic shield (OS) providing >= 85% optical coverage for low-noise subsea telemetryISO 13628-5 / IEC 60092-350 |
| 5 | Subsea Outer Jacket | Heavy-duty black polyether polyurethane (PUR) outer jacket formulated for continuous deep-water immersion and wet-mate overmoldingISO 13628-5 / IEC 60092-350 |
Built to ISO 13628-5 / IEC 60092-350 with conductors (8x16 awg / 1.34 mm²) and subsea outer jacket
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to ISO 13628-5 / IEC 60092-350 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| P8C16#OS Construction Schedule (−40…+80 °C) | |||||||
| P4C16#OS (4×16 AWG Screened Subsea) | 4 × 16 AWG (1.34 mm²) | 26/30 AWG tinned Cu + OS braid | 9.6 | 135 | 1.1 | 60 | |
| P8C16#OS (8×16 AWG Screened Subsea) | 8 × 16 AWG (1.34 mm²) | 26/30 AWG tinned Cu + OS braid | 12.7 | 235 | 2.1 | 80 | |
| P12C16#OS (12×16 AWG Screened Subsea) | 12 × 16 AWG (1.34 mm²) | 26/30 AWG tinned Cu + OS braid | 14.9 | 330 | 3.0 | 90 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 4 × 16 AWG (1.34 mm²) | 14.60 | 600 V / 13 A per core | −40…+80 °C |
| 8 × 16 AWG (1.34 mm²) | 14.60 | 600 V / 10 A per core | −40…+80 °C |
| 12 × 16 AWG (1.34 mm²) | 14.60 | 600 V / 8.5 A per core | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (ISO 13628-5 / IEC 60092-350) | Electrical parameters and outer diameter within ISO 13628-5 / IEC 60092-350 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (ISO 13628-5 / IEC 60092-350) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (ISO 13628-5 / IEC 60092-350) | Verified structural and dielectric integrity across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.