Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
Wet-Mate Shielded Twisted Pair (PTSP Series: P2TSP20#, P3TSP20#, P4TSP20#, P4TSP18#, P8TSP20#, P3TSP22#/1TSP18#) Individually Foil-Screened PP-Insulated PUR Underwater Connector Cable (Doc. 2013015SC PTSP, 600 V, -30 °C to +80 °C).
Typical values for this cable type, based on Subsea Doc. 2013015SC (PTSP Series) Shielded Pair Connector — confirmed in the datasheet and quotation for your order.
Application fit
Wet-Mate Shielded Twisted Pair (PTSP Series: P2TSP20#, P3TSP20#, P4TSP20#, P4TSP18#, P8TSP20#, P3TSP22#/1TSP18#) Individually Foil-Screened PP-Insulated PUR Underwater Connector Cable (Doc. 2013015SC PTSP, 600 V, -30 °C to +80 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: P4TSP20# (PTSP SERIES) (Subsea Doc. 2013015SC (PTSP Series) Shielded Pair Connector) featuring stranded tinned copper pairs (4×2×20 awg), pair color code and black halogen-free pur jacket (ø10.4 mm) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Tinned Copper Pairs (4×2×20 AWG) | 19/32 AWG (0.50 mm²) tinned copper with 600 V DC polypropylene (PP) insulation |
| 2 | Pair Color Code | Pair 1: Black/White · Pair 2: Red/Green · Pair 3: Orange/Blue · Pair 4: Wh-Bk/Rd-Bk |
| 3 | Individual Alu/PET Foil & Drain Wire | 20 AWG tinned copper drain wire + Alu/Polyester tape + adhesive clear isolation tape |
| 4 | Plastic Fillers & Clear Polyester Binder | Plastic roundness fillers in center/interstices + overall clear Polyester binder tape |
| 5 | Black Halogen-Free PUR Jacket (Ø10.4 mm) | 1.50 mm moldable polyurethane outer sheath for Wet-Mate connector overmolding |
Built to Subsea Doc. 2013015SC (PTSP Series) Shielded Pair Connector with stranded tinned copper pairs (4×2×20 awg) and black halogen-free pur jacket (ø10.4 mm)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to Subsea Doc. 2013015SC (PTSP Series) Shielded Pair Connector for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| P4TSP20# (PTSP SERIES) Construction Schedule (−30…+80 °C) | |||||||
| P4TSP20# Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| P4TSP20# Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| P4TSP20# Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 600 V (45–100 Ω data) | −30…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 600 V (45–100 Ω data) | −30…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 600 V (High-Power Hybrid) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (Subsea Doc. 2013015SC (PTSP Series) Shielded Pair Connector) | DC resistance at 20 °C / optical attenuation and outer diameter within Subsea Doc. 2013015SC (PTSP Series) Shielded Pair Connector tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (Subsea Doc. 2013015SC (PTSP Series) Shielded Pair Connector) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (Subsea Doc. 2013015SC (PTSP Series) Shielded Pair Connector) | Verified submersion integrity, tensile load and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.